摘要
Purpose: Complex hemodynamics assessments, as those related to carotid stenosis, are not always easily straightforward due to multifaceted challenges presented by the collateral flow in the Circle of Willis (CoW) and brain flow autoregulation. Advanced computational and benchtop methods to investigate hemodynamics aspects related to such complex flows are often used, however both have limitations and could lead to results which may diverge. In this study we investigated these aspects by performing correlated computational fluid dynamics (CFD) simulations and benchtop experiments in patient specific 3D printed phantoms. Materials and Methods: To investigate the flow in patients with carotid stenosis, we built two patient specific phantoms which contained the arterial lesion of interest, all main arteries leading to the brain, the CoW and main arteries branching from it. Each phantom was connected to a generic aortic arch. A programmable pump was connected and flow parameters were measured proximal and distal to the lesion and the contralateral arteries. The patient 3D geometry was used to perform a set of CFD simulations where inflow boundary conditions matched the experimental ones. Flow conditions were recorded at the same locations as the experimental setup. Further exploration into the translation from experimental to CFD was also performed by customizing vascular segmentation and physically manipulating arterial compliance properties. Results: We initially observed significant differences between the CFD recordings and the experimental setup. Most of the differences were due to changes in phantom geometry when subjected to physiological pressures and simplistic outflow boundary conditions in the CFD simulations which do not account for pulsatility and nonlinear phenomena. Further work confirms the need for dynamic mesh behavior within CFD simulations attempting to computationally mimic 3D-printed benchtop experiments. Additionally, CFD simulation may benefit from considering geometry specific to a 3D-printed vascular phantom.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Influence of Hemodynamic Factors on Rupture of Intracranial Aneurysms: Patient-Specific 3D Mirror Aneurysms Model Computational Fluid Dynamics Simulation
    Lu, G.
    Huang, L.
    Zhang, X. L.
    Wang, S. Z.
    Hong, Y.
    Hu, Z.
    Geng, D. Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) : 1255 - 1261
  • [22] Droplet-droplet collision simulation in spray drying by using 3D computational fluid dynamics
    Zhang Z.
    Zhang S.
    Xu C.
    International Journal of Advancements in Computing Technology, 2011, 3 (10) : 258 - 265
  • [23] Effects of 3D Flow-Channel Configurations on the Performance of PEMFC using Computational Fluid Dynamics
    Han, Kyoung-Ho
    Yoon, Do Young
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2016, 54 (06): : 847 - 853
  • [24] Treatment Planning for Image-Guided Neuro-Vascular Interventions Using Patient-Specific 3D Printed Phantoms
    Russ, M.
    O'Hara, R.
    Nagesh, S. V. Setlur
    Mokin, M.
    Jimenez, C.
    Siddiqui, A.
    Bednarek, D.
    Rudin, S.
    Ionita, C.
    MEDICAL IMAGING 2015: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2015, 9417
  • [25] Prescribed Flow in 3D Printed Models for Determination of Coronary Ischemia: A Comparison to a Computational Fluid Dynamic-based Assessment
    Kolli, Kranthi K.
    Xiong, Guanglei
    Ha, Seongmin
    Soohoo, Hilary
    Min, James K.
    CIRCULATION, 2016, 134
  • [26] Rehearsals using patient-specific 3D-printed aneurysm models for simulation of endovascular embolization of complex intracranial aneurysms: 3D SIM study
    Le Bras, Anthony
    Boustia, Fakhreddine
    Janot, Kevin
    Le Pabic, Estelle
    Ouvrard, Mathilde
    Fougerou-Leurent, Claire
    Ferre, Jean-Christophe
    Gauvrit, Jean-Yves
    Eugene, Francois
    JOURNAL OF NEURORADIOLOGY, 2023, 50 (01) : 86 - 92
  • [28] Comparison of predicting drag methods using computational fluid dynamics in 2d/3d viscous flow
    ZiQiang Zhu
    XiaoLu Wang
    Jie Liu
    Zhou Liu
    Science in China Series E: Technological Sciences, 2007, 50 : 534 - 549
  • [29] Comparison of predicting drag methods using computational fluid dynamics in 2d/3d viscous flow
    Zhu, ZiQiang
    Wang, XiaoLu
    Liu, Jie
    Liu, Zhou
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2007, 50 (05): : 534 - 549
  • [30] Rehearsal simulation to determine the size of device for left atrial appendage occlusion using patient-specific 3D-printed phantoms
    Dayeong Hong
    Sojin Moon
    Youngjin Cho
    Il-Young Oh
    Eun Ju Chun
    Namkug Kim
    Scientific Reports, 12