Bilateral comparison of luminous flux (EURAMET.PR-K4.3)

被引:0
|
作者
Pons, Alicia [1 ]
Campos, Joaquin [1 ]
Sametoglu, Ferhat [2 ]
机构
[1] CSIC, IO, Inst Opt Daza de Valdes, C Serrano 144, Madrid 28006, Spain
[2] Opt Labs, Dr Zeki Acar Cad 1,TUBITAK Gebze Yerleskesi, TR-41470 Kocaeli, Turkey
关键词
Luminous flux; PR K4; Bilateral Comparison;
D O I
10.1088/0026-1394/56/1A/02003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This report gives the result of a bilateral comparison of luminous flux between the Instituto de Optica, IO-CSIC (Spain) and the Ulusal Metroloji Enstitusu, TUBITAK UME (Turkey). This bilateral comparison is intended to link the TUBITAK UME realized lumen to the CCPR K4 reference value. The measurement artefacts were specially developed transfer standard lamps for luminous flux of the Polaron LF200W type. The comparison and its protocol were approved by the CCPR and registered with KCDB with the comparison number: EURAMET.PR-K4.3.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Final report: key comparison EURAMET.AUV.A-K5
    Avison, Janine
    Harris, Peter
    Robinson, Stephen
    Rodrigues, Dominique
    Guglielmone, Claudio
    Hof, Christian
    Sadikoglu, Enver
    Chushkov, Marin
    Zelenika, Slobodan
    Rosenkrantz, Peter
    Andersson, Hakan
    Fedtke, Thomas
    Koch, Christian
    Martin, Nieves Medina
    Ruiz, Salustiano
    Shawky, Hany
    METROLOGIA, 2019, 56 (1A) : 1 - 43
  • [32] 6TH COMPARISON OF NATIONAL STANDARDS OF LUMINOUS INTENSITY AND OF LUMINOUS FLUX (1985)
    BONHOURE, J
    METROLOGIA, 1987, 24 (04) : 157 - 162
  • [33] Key comparisons of air kerma and absorbed dose to water standards in 60Co radiation beam (EURAMET.RI(I)-K1.3 and EURAMET.RI(I)-K4.3)
    Nylund, R.
    Prez, L.A.D.
    Hetland, P.O.
    Andersen, C.E.
    Aviles, P.
    Mulas, C.G.
    Msimang, Z.
    Czap, L.
    Persson, L.
    Metrologia, 2023, 60 (1A)
  • [34] FINAL REPORT on the BILATERAL KEY COMPARISON EURAMETMM-K2.3 "Comparison of 10 kg, 500 g and 20 g Mass Standards" (EURAMET 1198)
    Mitsas, Chris
    Mangutova-Stoilkovska, Bianka
    METROLOGIA, 2012, 49
  • [35] EURAMET.QM-K12 EURAMET Key Comparison on the Determination of the Mass Fraction of Creatinine in Human Serum Final report
    Bell, D.
    Hopley, C.
    Ellison, S.
    O'Connor, G.
    Ohlendorf, R.
    Zakel, S.
    Henrion, A.
    Liu, Q.
    Peignaux, M.
    Delatour, V.
    Lampi, E.
    Kakoulides, E.
    METROLOGIA, 2013, 50
  • [36] International Comparison EURAMET.QM-K3.2019 - Automotive exhaust gases
    Ziel R.P.
    Zalewska E.
    van der Veen A.M.H.
    Kipphardt H.
    Tuma D.
    Esteban A.R.
    Vicente T.E.F.
    Mace T.
    Sutour C.
    Marioni F.
    Fűkő J.
    Szűcs L.
    Büki T.
    Nagyné Z.S.
    Cieciora D.
    Ochman G.
    Romanowski P.
    Lis A.
    Garnuszek M.
    Valkova M.
    Ackermann A.
    Pascale C.
    Niederhauser B.
    Tarhan T.
    Boztepe A.
    Beránek J.
    Bárta M.
    Metrologia, 2024, 60 (1 A)
  • [37] Final report on key comparison EURAMET.AUV.V-K2
    Kolasa, Joanna
    Virovska, Daniela
    METROLOGIA, 2020, 57 (1A)
  • [38] Supplementary Comparison EURAMET.EM-S19 EURAMET Project No. 688 Bilateral Comparison of Measurements of Current Transformers (CTs) Between BIM and UME Final Report
    Cayci, Hueseyin
    METROLOGIA, 2011, 48
  • [39] EURAMET key comparison no. EURAMET.T-K1: realisations of the ITS-90 from 2.6 K to 24.5561 K, using rhodium-iron resistance thermometers
    Gaiser, Christof
    Fellmuth, Bernd
    Steur, Peter
    Szmyrka-Grzebyk, Anna
    Manuszkiewicz, Henryk
    Lipinski, Leszek
    Peruzzi, Andrea
    Rusby, Richard
    Head, David
    METROLOGIA, 2017, 54
  • [40] Supplementary comparison EURAMET EM-S41 bilateral comparison of DC voltage reference standards (1,018 V and 10 V) (EURAMET.EM-S41)
    Blanc, Isabelle
    Sardjono, Hadi
    Syahadi, Mohamad
    METROLOGIA, 2020, 57 (1A)