Clinical application of a model-based cardiac stroke volume estimation method

被引:1
|
作者
Smith, Rachel [1 ]
Balmer, Joel [1 ]
Pretty, Christopher G. [1 ]
Shaw, Geoffrey M. [2 ]
Chase, J. Geoffrey [1 ]
机构
[1] Univ Canterbury, Dept Mech Engn, Canterbury, New Zealand
[2] Christchurch Hosp Intens Care Unit, Christchurch, New Zealand
来源
IFAC PAPERSONLINE | 2020年 / 53卷 / 02期
基金
欧盟地平线“2020”;
关键词
Pulse contour analysis; Pressure contour analysis; Windkessel model; Stroke volume; Cardiac output; Hemodynamic monitoring; Intensive care; PRESSURE; OUTPUT; PULSE; ANESTHESIA; ACCURACY; SHOCK;
D O I
10.1016/j.ifacol.2020.12.435
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A system is needed for monitoring stroke volume (SV) and cardiac output (CO) in unstable patients which is non-additionally invasive, reproducible and reliable in a variety of physiological states. This study evaluates SV estimation accuracy of a non-additionally invasive pulse contour analysis method implemented using a 3-element Windkessel model. The model lumps the properties of the arterial system into 3 parameters: characteristic impedance of the proximal aorta (Z), and resistance (R) and compliance (C) of the systemic arteries. Parameter products ZC and RC are dynamically identified from measured femoral arterial pressure waveforms, and Z is a static parameter obtained by calibration. The accuracy of the model is evaluated for a cohort of 9 liver transplant patients, using thermodilution as a reference method. Data were obtained from Vital Data Bank (VitalDB). The study thus provides independent assessment of a pulse contour analysis, proven in animal studies, in an uncontrolled clinical environment. The model tracked trends in SV well over the course of the surgery. However, the 95% range for percentage error was -88% to +53%, outside acceptable limits of +/- 45%. Main areas contributing to error for the model include the changing extent of reflected waves in the arterial system, dynamic response characteristics of fluid-filled pressure catheters, and the assumption of fixed Z parameter. Further investigation is needed to consider the contribution of these factors to SV estimation error by the model. Copyright (C) 2020 The Authors.
引用
收藏
页码:16137 / 16142
页数:6
相关论文
共 50 条
  • [41] Mixed model-based hazard estimation
    Cai, T
    Hyndman, RJ
    Wand, MP
    JOURNAL OF COMPUTATIONAL AND GRAPHICAL STATISTICS, 2002, 11 (04) : 784 - 798
  • [42] Model-Based Estimation of Knee Stiffness
    Pfeifer, Serge
    Vallery, Heike
    Hardegger, Michael
    Riener, Robert
    Perreault, Eric J.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (09) : 2604 - 2612
  • [43] Model-based estimation of individual fitness
    Link, WA
    Cooch, EG
    Cam, E
    JOURNAL OF APPLIED STATISTICS, 2002, 29 (1-4) : 207 - 224
  • [44] MODEL-BASED ESTIMATION OF BUILDING INFILTRATION
    Hao, Zhengwen
    O'Neill, Zheng
    2018 BUILDING PERFORMANCE ANALYSIS CONFERENCE AND SIMBUILD, 2018, : 37 - 44
  • [45] Neural model-based motion estimation
    Szostakowski, J
    Skoneczny, S
    Iwanowski, M
    ADVANCED SIGNAL PROCESSING: ALGORITHMS, ARCHITECTURES, AND IMPLEMENTATIONS VII, 1997, 3162 : 328 - 335
  • [46] Model-Based Pose Estimation by Consensus
    Jorstad, Anne
    Burlina, Philippe
    Wang, I-Jeng
    Lucarelli, Dennis
    DeMenthon, Daniel
    ISSNIP 2008: PROCEEDINGS OF THE 2008 INTERNATIONAL CONFERENCE ON INTELLIGENT SENSORS, SENSOR NETWORKS, AND INFORMATION PROCESSING, 2008, : 569 - 574
  • [47] HIERARCHICAL MODEL-BASED MOTION ESTIMATION
    BERGEN, JR
    ANANDAN, P
    HANNA, KJ
    HINGORANI, R
    LECTURE NOTES IN COMPUTER SCIENCE, 1992, 588 : 237 - 252
  • [48] ADAPTIVE MODEL-BASED MOTION ESTIMATION
    CRINON, RJ
    KOLODZIEJ, WJ
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 1994, 3 (05) : 469 - 481
  • [49] Rethinking Model-Based Gaze Estimation
    Kaur, Harsimran
    Jindal, Swati
    Manduchi, Roberto
    PROCEEDINGS OF THE ACM ON COMPUTER GRAPHICS AND INTERACTIVE TECHNIQUES, 2022, 5 (02)