Clinical application of a model-based cardiac stroke volume estimation method

被引:1
|
作者
Smith, Rachel [1 ]
Balmer, Joel [1 ]
Pretty, Christopher G. [1 ]
Shaw, Geoffrey M. [2 ]
Chase, J. Geoffrey [1 ]
机构
[1] Univ Canterbury, Dept Mech Engn, Canterbury, New Zealand
[2] Christchurch Hosp Intens Care Unit, Christchurch, New Zealand
来源
IFAC PAPERSONLINE | 2020年 / 53卷 / 02期
基金
欧盟地平线“2020”;
关键词
Pulse contour analysis; Pressure contour analysis; Windkessel model; Stroke volume; Cardiac output; Hemodynamic monitoring; Intensive care; PRESSURE; OUTPUT; PULSE; ANESTHESIA; ACCURACY; SHOCK;
D O I
10.1016/j.ifacol.2020.12.435
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A system is needed for monitoring stroke volume (SV) and cardiac output (CO) in unstable patients which is non-additionally invasive, reproducible and reliable in a variety of physiological states. This study evaluates SV estimation accuracy of a non-additionally invasive pulse contour analysis method implemented using a 3-element Windkessel model. The model lumps the properties of the arterial system into 3 parameters: characteristic impedance of the proximal aorta (Z), and resistance (R) and compliance (C) of the systemic arteries. Parameter products ZC and RC are dynamically identified from measured femoral arterial pressure waveforms, and Z is a static parameter obtained by calibration. The accuracy of the model is evaluated for a cohort of 9 liver transplant patients, using thermodilution as a reference method. Data were obtained from Vital Data Bank (VitalDB). The study thus provides independent assessment of a pulse contour analysis, proven in animal studies, in an uncontrolled clinical environment. The model tracked trends in SV well over the course of the surgery. However, the 95% range for percentage error was -88% to +53%, outside acceptable limits of +/- 45%. Main areas contributing to error for the model include the changing extent of reflected waves in the arterial system, dynamic response characteristics of fluid-filled pressure catheters, and the assumption of fixed Z parameter. Further investigation is needed to consider the contribution of these factors to SV estimation error by the model. Copyright (C) 2020 The Authors.
引用
收藏
页码:16137 / 16142
页数:6
相关论文
共 50 条
  • [31] Line Model-Based Drift Estimation Method for Indoor Monocular Localization
    Feng, Guanyuan
    Ma, Lin
    Tan, Xuezhi
    2018 IEEE 88TH VEHICULAR TECHNOLOGY CONFERENCE (VTC-FALL), 2018,
  • [32] A Monte Carlo method for the model-based estimation of nuclear reactor dynamics
    Cadini, F.
    Zio, E.
    ANNALS OF NUCLEAR ENERGY, 2007, 34 (10) : 773 - 781
  • [33] Generalized Parameter Estimation Method for Model-Based Real Time Optimization
    Zhang, Duo
    Wang, Kexin
    Xu, Zuhua
    Tula, Anjan K.
    Shao, Zhijiang
    Zhang, Zhengjiang
    Biegler, Lorenz T.
    CHEMICAL ENGINEERING SCIENCE, 2022, 258
  • [34] MODEL-BASED METHOD FOR SPILLOVER CORRECTION IN DYNAMIC CARDIAC PET FDG STUDIES - THE APPLICATION TO HUMAN-SUBJECTS
    LI, X
    FENG, D
    LIN, KP
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P105 - P105
  • [35] A model-based parameter estimation of current distribution along lightning return stroke channel
    Karami, Hamid. R.
    Moini, Rouzbeh.
    Sadeghi, S. H. Hesam.
    EMC ZURICH-MUNICH 2007, SYMPOSIUM DIGEST, 2007, : 317 - 320
  • [36] ESTIMATION OF STROKE VOLUME IN DOG BY A PULSE CONTOUR METHOD
    KOUCHOUKOS, NT
    SHEPPARD, LC
    MCDONALD, DA
    CIRCULATION RESEARCH, 1970, 26 (05) : 611 - +
  • [37] Model-based road friction estimation
    Shim, T
    Margolis, D
    VEHICLE SYSTEM DYNAMICS, 2004, 41 (04) : 249 - 276
  • [38] Model-Based Correlated Channels Estimation
    Alimorad Mahmoudi
    Wireless Personal Communications, 2017, 92 : 483 - 493
  • [39] MODEL-BASED ATTITUDE ESTIMATION FOR MULTICOPTERS
    Baranek, Radek
    Solc, Frantisek
    ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2014, 12 (05) : 501 - 510
  • [40] Model-Based Correlated Channels Estimation
    Mahmoudi, Alimorad
    WIRELESS PERSONAL COMMUNICATIONS, 2017, 92 (02) : 483 - 493