Calibration and validation of confocal spectral imaging systems

被引:41
|
作者
Lerner, JM
Zucker, RM
机构
[1] LightForm Inc, Hillsborough, NJ 08844 USA
[2] US EPA, Reprod Toxicol Div, Natl Hlth & Environm Effects Res Lab, Res Triangle Pk, NC 27711 USA
关键词
confocal microscope; wavelength calibration; spectral calibration; spectral imaging; Zeiss; Leica; SKY; PARISS; quality assurance; validation; photomultiplier tube;
D O I
10.1002/cyto.a.20087
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Confocal spectral imaging (CSI) microscopic systems currently on the market delineate multiple fluorescent proteins, labels, or dyes within biological specimens by performing spectral characterizations. However, some CSI systems have been found to present inconsistent spectral profiles of reference spectra within a particular system and between related and unrelated instruments. This variability confirms that there is a need for a standardized, objective calibration and validation protocol. Methods: Our protocol uses an inexpensive multi-ion discharge lamp (MIDL) that contains Hg+, Ar+, and inorganic fluorophores that emit distinct, stable, spectral features in place of a sample. We derived reference spectra from the MIDL data to accurately predict the spectral resolution, ratio of wavelength to wavelength, contrast, and aliasing parameters of any CSI system. We were also able to predict and confirm the influence of pinhole diameter on spectral profiles. Results: Using this simulation, we determined that there was good agreement between observed and theoretical expectations, thus enabling us to identify malfunctioning subsystems. We examined eight CSI systems and one non-confocal spectral system, all of which displayed spectral inconsistencies. No instrument met its optimal performance expectations. In two systems, we established the need for factory realignment that had not been otherwise recognized. Conclusions: We found that using a primary light source that emits an absolute standard "reference spectrum" enabled us to diagnose instrumental errors and measure accuracy and reproducibility under normalized conditions. With this information, a CSI operator can determine whether a CSI system is working optimally and make objective comparisons with the performance of other CSI systems. We determined that, if CSI systems were standardized to produce the same spectral profile of a MIDL lamp, researchers could be confident that the same experimental findings would be obtained on any CSI system. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:8 / 34
页数:27
相关论文
共 50 条
  • [41] Research on methods of spectral calibration and radiometric calibration of the windowing Fourier transform imaging spectrometer
    Zhang, Lei
    Gao, Jiao Bo
    Zhao, Yu Jie
    Luo, Yan Ling
    Xiao, Xiang Guo
    Zhang, Fang
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: IMAGING SPECTROMETER TECHNOLOGIES AND APPLICATIONS, 2013, 8910
  • [42] Spectral Characterization of the Dunhuang Calibration/Validation Site using Hyperspectral Measurements
    Cao, Changyong
    Ma, Lingling
    Uprety, Sirish
    Li, Chuanrong
    Tang, Lingli
    EARTH OBSERVING MISSIONS AND SENSORS: DEVELOPMENT, IMPLEMENTATION, AND CHARACTERIZATION, 2010, 7862
  • [43] Scene-based spectral calibration assessment of high spectral resolution imaging spectrometers
    Guanter, Luis
    Segl, Karl
    Sang, Bernhard
    Alonso, Luis
    Kaufmann, Hermann
    Moreno, Jose
    OPTICS EXPRESS, 2009, 17 (14): : 11594 - 11606
  • [44] SPECTRAL-LINE IMAGING .2. CALIBRATION AND ANALYSIS
    VANGORKOM, JH
    EKERS, RD
    SYNTHESIS IMAGING IN RADIO ASTRONOMY, 1989, 6 : 341 - 353
  • [45] Geometrical Calibration of an AOTF Hyper-spectral Imaging System
    Spiclin, Ziga
    Katrasnik, Jaka
    Buermen, Miran
    Pernus, Franjo
    Likar, Bostjan
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES III, 2010, 7556
  • [46] Improved Methods for Spectral Calibration of On-Orbit Imaging Spectrometers
    Wang, Tianxing
    Yan, Guangjian
    Ren, Huazhong
    Mu, Xihan
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2010, 48 (11): : 3924 - 3931
  • [47] Calibration of coherence imaging spectroscopy using spectral line sources
    Ueda, Kenji
    Nishiura, Masaki
    Kenmochi, Naoki
    Yoshida, Zensho
    Nakamura, Kaori
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (07):
  • [48] Spectral calibration of imaging spectrometers by atmospheric absorption feature matching
    Neville, Robert A.
    Sun, Lixin
    Staenz, Karl
    CANADIAN JOURNAL OF REMOTE SENSING, 2008, 34 : S29 - S42
  • [49] A spectral detector using the dispersion of an acousto-optic tunable filter for confocal spectral imaging microscopy
    Song, InCheon
    Gweon, Dae-Gab
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (08)
  • [50] Validation and calibration of models for reaction-diffusion systems
    Dilao, R
    Sainhas, J
    INTERNATIONAL JOURNAL OF BIFURCATION AND CHAOS, 1998, 8 (06): : 1163 - 1182