A large area plastic scintillation detector with 4-corner-readout

被引:5
|
作者
Tang, Shu-Wen [1 ]
Yu, Yu-Hong [1 ]
Zhou, Yong [1 ,2 ]
Sun, Zhi-Yu [1 ]
Zhang, Xue-Heng [1 ]
Wang, Shi-Tao [1 ]
Yue, Ke [1 ]
Liu, Long-Xiang [1 ]
Fang, Fang [1 ]
Yan, Duo [1 ,2 ]
Sun, Yu [1 ,2 ]
Wang, Zhao-Min [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
scintillation detector; 4-corner-readout; time resolution; position resolution; HIGH-RESOLUTION; TIME;
D O I
10.1088/1674-1137/40/5/056001
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
A 760 mm x 760 mm x 30 mm plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and gamma rays. A position independent effective time T-eff has been found, indicating this detector can be used as a TOF detector. The hit position can also be reconstructed by the time from the four corners. A TOF resolution of 236 ps and a position resolution of 48 mm have been achieved, and the detection efficiency has also been investigated.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Preliminary Characterization of a Stemless Plastic Scintillation Detector
    Hupman, M.
    Monajemi, T.
    Hill, I.
    Syme, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E102 - E102
  • [32] Plastic scintillation detector validation for kV dosimetry
    Lessard, F.
    Archambault, L.
    Plamondon, M.
    Despres, P.
    Therriault-Proulx, F.
    Beddar, S.
    Beaulieu, L.
    MEDICAL PHYSICS, 2012, 39 (07) : 4646 - 4646
  • [33] Fabrication and characterization of a stemless plastic scintillation detector
    Hupman, Michael A.
    Monajemi, Thalat
    Valitova, Irina
    Hill, Ian G.
    Syme, Alasdair
    MEDICAL PHYSICS, 2020, 47 (11) : 5882 - 5889
  • [34] The new positron plastic scintillation detector (PPSD)
    Dietzel, Guenter
    Rausch, Edvin
    Malik, Noeen
    Solbach, Christoph
    Reske, Sven
    Machulla, Hans-Juergen
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [35] BETA DETECTOR UTILIZING PLASTIC SCINTILLATION FIBERS
    HARDIE, G
    EZOP, JJ
    PRESTON, CC
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1964, 7 (02): : 340 - &
  • [36] NEW RADIATION DETECTOR OF PLASTIC SCINTILLATION FIBER
    IMAI, SI
    SORAMOTO, S
    MOCHIKI, KI
    IGUCHI, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (04): : 1093 - 1097
  • [37] A THIN LARGE AREA PLASTIC SCINTILLATION COUNTER FOR STUDY OF PRIMARY COSMIC RAYS
    AGRAWAL, PC
    KUNTE, PK
    NUCLEAR INSTRUMENTS & METHODS, 1968, 63 (03): : 258 - &
  • [38] Sensitivity of GAGG based scintillation neutron detector with SiPM readout
    Fedorov, A.
    Gurinovich, V
    Guzov, V
    Dosovitskiy, G.
    Korzhik, M.
    Kozhemyakin, V
    Lopatik, A.
    Kozlov, D.
    Mechinsky, V
    Retivov, V
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (10) : 2306 - 2312
  • [39] Development of a cylindrical tracking detector with multichannel scintillation fibers and pixelated photon detector readout
    Akazawa, Y.
    Miwa, K.
    Honda, R.
    Shiozaki, T.
    Chiga, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 193 - 196
  • [40] LARGE SCINTILLATION DETECTOR FOR PHOTONEUTRON REACTIONS
    COOK, BC
    JONES, CC
    NUCLEAR INSTRUMENTS & METHODS, 1968, 59 (02): : 229 - &