Surgeon's and patient's radiation exposure during percutaneous thoraco-lumbar pedicle screw fixation: A prospective multicenter study of 100 cases

被引:15
|
作者
Kouyoumdjian, Pascal [1 ]
Gras-Combe, Guillaume [2 ]
Grelat, Mickael [3 ]
Fuentes, Stephane [4 ]
Blondel, Benjamin [5 ]
Tropiano, Patrick [5 ]
Zairi, Fahed [6 ]
Beaurain, Jacques [3 ]
Charles, Yann-Philippe [7 ]
Dhenin, Alexandre [1 ]
Elfertit, Hassan [8 ]
Le Roy, Julien [9 ]
Greffier, Joel [10 ]
Lonjon, Nicolas [2 ]
机构
[1] Univ Montpellier I, Hop Caremeau, CHU Nimes, Orthoped Surg,Spine Unit, F-30029 Nimes, France
[2] CHU Montpellier, Hop Gui de Chauliac, Neurosurg Unit, F-34000 Montpellier, France
[3] CHU Dijon Bourgogne, Neurosurg Unit, F-21000 Dijon, France
[4] Hop La Timone, AP HM, Neurosurg Unit, F-13385 Marseille, France
[5] Hop La Timone, AP HM, Spine Unit, Orthoped Surg, F-13385 Marseille, France
[6] Hop Roger Salengro, CHR, Neurosurg Units, F-59037 Lille, France
[7] CHRU Strasbourg, Spine Unit, Orthoped Surg, BP 426, F-67091 Strasbourg, France
[8] CHU Nimes, Hop Caremeau, Neurosurg Unit, F-30029 Nimes, France
[9] CHRU Montpellier, Dept Radiat Phys, F-34295 Montpellier, France
[10] CHU Nimes, Hop Caremeau, Dept Med Imaging, F-30029 Nimes, France
关键词
Minimally invasive surgery; Percutaneous pedicle screw fixation; Fluoroscopy; C-arm; Radiation exposure; Spine surgeon; LUMBAR INTERBODY FUSION; COMPUTER-ASSISTED SURGERY; CONE-BEAM CT; SPINE SURGERY; INSERTION; NAVIGATION; INSTRUMENTATION; VERTEBROPLASTY; FLUOROSCOPY; ACCURACY;
D O I
10.1016/j.otsr.2018.05.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hypothesis: Percutaneous pedicle screw fixations (PPSF) are increasingly used in spine surgery, minimizing morbidity through less muscle breakdown but at the cost of intraoperative fluoroscopic guidance that generates high radiation exposure. Few studies have been conducted to measure them accurately. Material and methods: The objective of our study is to quantify, during a PPSF carried out in different experimented centers respecting current radiation protection recommendations, this irradiation at the level of the surgeon and the patient. We have prospectively included 100 FPVP procedures for which we have collected radiation doses from the main operator. For each procedure, the doses of whole-body radiation, lens and extremities were measured. Results: Our results show a mean whole body, extremity and lens exposure dose per procedure reaching 1.7 +/- 2.8 mu Sv, 204.7 +/- 260.9 mu Sv and 30.5 +/- 25.9 mu Sv, respectively. According to these values, the exposure of the surgeon's extremities and lens will exceed the annual limit allowed by the International Commission on Radiological Protection (ICRP) after 2440 and 4840 procedures respectively. Conclusion: Recent European guidelines will reduce the maximum annual exposure dose from 150 to 20 mSv. The number of surgical procedures to not reach the eye threshold, according to our results, should not exceed 645 procedures per year. Pending the democratization of neuronavigation systems, the use of conventional fluoroscopy exposes the eyes in the first place. Therefore they must be protected by leaded glasses. (C) 2018 Published by Elsevier Masson SAS.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 44 条
  • [41] The iGreenGO Study: The Clinical Role of Indocyanine Green Imaging Fluorescence in Modifying the Surgeon's Conduct During the Surgical Treatment of Advanced Gastric Cancer-Study Protocol for an International Multicenter Prospective Study
    Lombardi, Pietro Maria
    Mazzola, Michele
    Nicastro, Vincenzo
    Giacopuzzi, Simone
    Baiocchi, Gian Luca
    Castoro, Carlo
    Rosati, Riccardo
    Romario, Uberto Fumagalli
    Bonavina, Luigi
    Staderini, Fabio
    Gockel, Ines
    Gregori, Dario
    De Martini, Paolo
    Gualtierotti, Monica
    Danieli, Maria
    Beretta, Simona
    Mutignani, Massimiliano
    Forti, Edoardo
    Ferrari, Giovanni
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [42] Comparison of instrumented posterolateral fusion versus percutaneous pedicle screw fixation combined with anterior lumbar interbody fusion in elderly patients with L5-S1 isthmic spondylolisthesis and foraminal stenosis Clinical article (vol 15, pg 311, 2011)
    Shim, Jung Hyun
    Park, Choon Keun
    JOURNAL OF NEUROSURGERY-SPINE, 2011, 15 (03) : 343 - 343
  • [43] Letter to the Editor concerning "Novel augmentation technique of percutaneous pedicle screw fixation using hydroxyapatite granules in the osteoporotic lumbar spine: a cadaveric biomechanical analysis" by H. Kanno et al. (Eur Spine J [2021]; doi: 10.1007/s00586-020-06451-2)
    Morimoto, Tadatsugu
    Yoshihara, Tomohito
    Kobayashi, Takaomi
    Mawatari, Masaaki
    EUROPEAN SPINE JOURNAL, 2022, 31 (01) : 210 - 211
  • [44] Letter to the Editor concerning “Novel augmentation technique of percutaneous pedicle screw fixation using hydroxyapatite granules in the osteoporotic lumbar spine: a cadaveric biomechanical analysis” by H. Kanno et al. (Eur Spine J [2021]; doi: 10.1007/s00586-020-06451-2)
    Tadatsugu Morimoto
    Tomohito Yoshihara
    Takaomi Kobayashi
    Masaaki Mawatari
    European Spine Journal, 2022, 31 : 210 - 211