Surgeon's and patient's radiation exposure during percutaneous thoraco-lumbar pedicle screw fixation: A prospective multicenter study of 100 cases

被引:15
|
作者
Kouyoumdjian, Pascal [1 ]
Gras-Combe, Guillaume [2 ]
Grelat, Mickael [3 ]
Fuentes, Stephane [4 ]
Blondel, Benjamin [5 ]
Tropiano, Patrick [5 ]
Zairi, Fahed [6 ]
Beaurain, Jacques [3 ]
Charles, Yann-Philippe [7 ]
Dhenin, Alexandre [1 ]
Elfertit, Hassan [8 ]
Le Roy, Julien [9 ]
Greffier, Joel [10 ]
Lonjon, Nicolas [2 ]
机构
[1] Univ Montpellier I, Hop Caremeau, CHU Nimes, Orthoped Surg,Spine Unit, F-30029 Nimes, France
[2] CHU Montpellier, Hop Gui de Chauliac, Neurosurg Unit, F-34000 Montpellier, France
[3] CHU Dijon Bourgogne, Neurosurg Unit, F-21000 Dijon, France
[4] Hop La Timone, AP HM, Neurosurg Unit, F-13385 Marseille, France
[5] Hop La Timone, AP HM, Spine Unit, Orthoped Surg, F-13385 Marseille, France
[6] Hop Roger Salengro, CHR, Neurosurg Units, F-59037 Lille, France
[7] CHRU Strasbourg, Spine Unit, Orthoped Surg, BP 426, F-67091 Strasbourg, France
[8] CHU Nimes, Hop Caremeau, Neurosurg Unit, F-30029 Nimes, France
[9] CHRU Montpellier, Dept Radiat Phys, F-34295 Montpellier, France
[10] CHU Nimes, Hop Caremeau, Dept Med Imaging, F-30029 Nimes, France
关键词
Minimally invasive surgery; Percutaneous pedicle screw fixation; Fluoroscopy; C-arm; Radiation exposure; Spine surgeon; LUMBAR INTERBODY FUSION; COMPUTER-ASSISTED SURGERY; CONE-BEAM CT; SPINE SURGERY; INSERTION; NAVIGATION; INSTRUMENTATION; VERTEBROPLASTY; FLUOROSCOPY; ACCURACY;
D O I
10.1016/j.otsr.2018.05.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hypothesis: Percutaneous pedicle screw fixations (PPSF) are increasingly used in spine surgery, minimizing morbidity through less muscle breakdown but at the cost of intraoperative fluoroscopic guidance that generates high radiation exposure. Few studies have been conducted to measure them accurately. Material and methods: The objective of our study is to quantify, during a PPSF carried out in different experimented centers respecting current radiation protection recommendations, this irradiation at the level of the surgeon and the patient. We have prospectively included 100 FPVP procedures for which we have collected radiation doses from the main operator. For each procedure, the doses of whole-body radiation, lens and extremities were measured. Results: Our results show a mean whole body, extremity and lens exposure dose per procedure reaching 1.7 +/- 2.8 mu Sv, 204.7 +/- 260.9 mu Sv and 30.5 +/- 25.9 mu Sv, respectively. According to these values, the exposure of the surgeon's extremities and lens will exceed the annual limit allowed by the International Commission on Radiological Protection (ICRP) after 2440 and 4840 procedures respectively. Conclusion: Recent European guidelines will reduce the maximum annual exposure dose from 150 to 20 mSv. The number of surgical procedures to not reach the eye threshold, according to our results, should not exceed 645 procedures per year. Pending the democratization of neuronavigation systems, the use of conventional fluoroscopy exposes the eyes in the first place. Therefore they must be protected by leaded glasses. (C) 2018 Published by Elsevier Masson SAS.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 44 条
  • [21] Are lead glasses necessary? A prospective multicenter cohort study on radiation exposure to the operator's eyes during urologic surgery
    Handmer, M.
    Dias, M.
    Rashid, P.
    Chalasani, V.
    BJU INTERNATIONAL, 2018, 121 : 31 - 32
  • [22] Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system
    Pietro Scarone
    Anindita Chatterjea
    Inge Jenniskens
    Tim Klüter
    Matthias Weuster
    Sebastian Lippross
    Stefano Presilla
    Daniela Distefano
    Vito Chianca
    Sam Sedaghat
    Melissa Nelson
    Finn Lampe
    Andreas Seekamp
    European Spine Journal, 2022, 31 : 3098 - 3108
  • [23] Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system
    Pietro, Scarone
    Chatterjea, Anindita
    Inge, Jenniskens
    Tim, Kluter
    Matthias, Weuster
    Sebastian, Lippross
    Stefano, Presilla
    Distefano, Daniela
    Vito, Chianca
    Sam, Sedaghat
    Nelson, Melissa
    Finn, Lampe
    Andreas, Seekamp
    EUROPEAN SPINE JOURNAL, 2022, 31 (11) : 3098 - 3108
  • [24] Ultrasound-guided Jamshidi needle puncture to reduce radiation exposure during percutaneous pedicle screw placement: study protocol for a randomised controlled trial
    Wu, Tong
    Chen, Yi-feng
    Huang, Ying
    Meng, Fan-he
    Lu, Jing-han
    Liu, Da
    BMJ OPEN, 2023, 13 (03):
  • [25] Short-Term Comparison Between Unilateral Versus Bilateral Percutaneous Pedicle Screw Fixation in Short-Level Lateral Lumbar Interbody Fusion-A Prospective Randomized Study
    Hiyama, Akihiko
    Katoh, Hiroyuki
    Sakai, Daisuke
    Sato, Masato
    Watanabe, Masahiko
    GLOBAL SPINE JOURNAL, 2024, 14 (05) : 1485 - 1497
  • [26] Radiation Exposure to the Surgeon and the Patient During Posterior Lumbar Spinal Instrumentation A Prospective Randomized Comparison of Navigated Versus Non-navigated Freehand Techniques
    Villard, Jimmy
    Ryang, Yu-Mi
    Demetriades, Andreas K.
    Reinke, Andreas
    Behr, Michael
    Preuss, Alexander
    Meyer, Bernhard
    Ringel, Florian
    SPINE, 2014, 39 (13) : 1004 - 1009
  • [27] Local Anesthesia and Conscious Sedation Does Not Affect Patient's Mood and Anxiety Levels during Percutaneous Endoscopic Lumbar Diskectomy: A Prospective Study
    Erken, H. Yener
    Karaeminogullari, Oguz
    Yilmaz, Onur
    Mirel, Kerem
    Ozer, R. Ozgur
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2022, 83 (05) : 435 - 441
  • [28] Paraspinal Muscle Sparing versus Percutaneous Screw Fixation: A Prospective and Comparative Study for the Treatment of L5-S1 Spondylolisthesis
    Jang, Kun Soo
    Kim, Heyun Sung
    Ju, Chang Il
    Kim, Seok Won
    Lee, Sung Myung
    Shin, Ho
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2011, 49 (03) : 163 - 166
  • [29] Poor bone mineral density aggravates adjacent segment's motility compensation in patients with oblique lumbar interbody fusion with and without pedicle screw fixation: An in silico study
    Huang, Chen-Yi
    Zhang, Zi-Fan
    Zhang, Xiao-Yu
    Liu, Fei
    Fang, Zhong-Xin
    Xi, Zhi-Peng
    Li, Jing-Chi
    FRONTIERS IN SURGERY, 2022, 9
  • [30] The surgeon's real dose exposure during balloon kyphoplasty procedure and evaluation of the cement delivery system: a prospective study
    Schils, Frederic
    Schoojans, Werner
    Struelens, Lara
    EUROPEAN SPINE JOURNAL, 2013, 22 (08) : 1758 - 1764