Performance of a new digital flat panel detector in the detection of artificial bone lesions: A comparison with conventional screen-film radiography and phosphor-storage radiography

被引:0
|
作者
Ludwig, K
Lenzen, H
Kamm, K
Link, TM
Diederich, S
Wormanns, D
机构
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
1295
引用
下载
收藏
页码:517 / 517
页数:1
相关论文
共 50 条
  • [31] Digital amorphous silicon flat-panel detector vs screen-film and storage phosphor systems in chest imaging: Comparison of the entrance skin dose
    Smeets, PV
    Bacher, K
    Duyck, P
    Verstraete, KL
    Thierens, H
    RADIOLOGY, 2002, 225 : 382 - 382
  • [32] Comparison of a digital flat-panel versus screen-film, photofluorography and storage-phosphor systems by detection of simulated lung adenocarcinorna lesions using hard copy images
    Ono, K
    Yoshitake, T
    Akahane, K
    Yamada, Y
    Maeda, T
    Kai, M
    Kusama, T
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (934): : 922 - 927
  • [33] A digital flat-panel detector system in low-dose radiography of the pelvis in children evaluated for developmental dysplasia of the hip: Comparison to storage-phosphor radiography
    Ludwig, K
    Ahlers, K
    Kloska, SP
    Vieth, V
    Heindel, WL
    RADIOLOGY, 2002, 225 : 379 - 380
  • [34] COST COMPARISON BETWEEN STORAGE-PHOSPHOR COMPUTED RADIOGRAPHY AND CONVENTIONAL FILM-SCREEN RADIOGRAPHY IN INTENSIVE-CARE MEDICINE
    PETERS, PE
    DYKSTRA, DE
    WIESMANN, W
    SCHLUCHTERMANN, J
    ADAM, D
    RADIOLOGE, 1992, 32 (11): : 536 - 540
  • [35] Performance comparison of an active matrix flat panel imager, computed radiography system, and a screen-film system at four standard radiation qualities
    Monnin, P
    Gutierrez, D
    Bulling, S
    Lepori, D
    Valley, JF
    Verdun, FR
    MEDICAL PHYSICS, 2005, 32 (02) : 343 - 350
  • [36] Digitale Thoraxradiographie: Flat-panel-Detektor oder Speicherfolie?Digital thorax radiography: flat-panel detector or storage phosphor plates
    C. Schaefer-Prokop
    M. Uffmann
    J. Sailer
    N. Kabalan
    C. Herold
    M. Prokop
    Der Radiologe, 2003, 43 : 351 - 361
  • [37] Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen
    Terue Okamura
    Saori Tanaka
    Koichi Koyama
    Nishida Norihumi
    Hideo Daikokuya
    Toshiyuki Matsuoka
    Kenji Kishimoto
    Masakatsu Hatagawa
    Hiroaki Kudoh
    Ryusaku Yamada
    European Radiology, 2002, 12 : 1741 - 1747
  • [38] Needle-based storage-phosphor detector radiography is superior to a conventional powder-based storage phosphor detector and a high-resolution screen-film system in small patients (budgerigars and mice)
    Wiebke Tebrün
    Eberhard Ludewig
    Claudia Köhler
    Julia Böhme
    Michael Pees
    Scientific Reports, 9
  • [39] Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen
    Okamura, T
    Tanaka, S
    Koyama, K
    Norihumi, N
    Daikokuya, H
    Matsuoka, T
    Kishimoto, K
    Hatagawa, M
    Kudoh, H
    Yamada, R
    EUROPEAN RADIOLOGY, 2002, 12 (07) : 1741 - 1747
  • [40] Needle-based storage-phosphor detector radiography is superior to a conventional powder-based storage phosphor detector and a high-resolution screen-film system in small patients (budgerigars and mice)
    Tebruen, Wiebke
    Ludewig, Eberhard
    Koehler, Claudia
    Boehme, Julia
    Pees, Michael
    SCIENTIFIC REPORTS, 2019, 9 (1)