Comparison of a digital flat-panel versus screen-film, photofluorography and storage-phosphor systems by detection of simulated lung adenocarcinorna lesions using hard copy images

被引:4
|
作者
Ono, K
Yoshitake, T
Akahane, K
Yamada, Y
Maeda, T
Kai, M
Kusama, T
机构
[1] Oita Prefectural Hosp, Oita 8708511, Japan
[2] Shin Beppu Hosp, Beppu, Oita 8740833, Japan
[3] Natl Inst Radiol Sci, Chiba 2638555, Japan
[4] Oita Univ, Oita 8701201, Japan
来源
BRITISH JOURNAL OF RADIOLOGY | 2005年 / 78卷 / 934期
关键词
D O I
10.1259/bjr/75926824
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare hard copy images from a flat-panel detector digital radiography system with conventional radiography, photofluorographic radiography and storage phosphor radiography for the detection of simulated lung adenocarcinoma lesions and also for radiation dose. To test the diagnostic performance of these four systems, the authors used 15 types of lung adenocarcinoma phantom according to Noguchi's classification and an anthropomorphic chest phantom. The visual evaluation of tumour detectability by four radiologists and two general thoracic surgeons was examined with a five-level confidence scale. Lung doses were measured with glass dosemeters for the chest radiology systems under the conditions used by each hospital and centre. Our results indicated that flat-panel detector digital radiography and storage phosphor radiography are not necessarily superior to conventional radiography and photofluorographic radiography for detecting lung adenocarcinomas when only hard copy images are used, and this suggests a need to carefully optimize chest radiography.
引用
收藏
页码:922 / 927
页数:6
相关论文
共 19 条
  • [1] Lumbar spine radiography: Digital flat-panel detector versus screen-film and storage-phosphor systems in monkeys as a pediatric model
    Ludwig, K
    Ahlers, K
    Wormanns, D
    Freund, M
    Bernhardt, TM
    Diederich, S
    Heindel, W
    [J]. RADIOLOGY, 2003, 229 (01) : 140 - 144
  • [2] Performance of a flat-panel detector in detecting artificial bone lesions: Comparison with conventional screen-film and storage-phosphor radiography
    Ludwig, K
    Lenzen, H
    Kamm, KF
    Link, TM
    Diederich, S
    Wormanns, D
    Heindel, W
    [J]. RADIOLOGY, 2002, 222 (02) : 453 - 459
  • [3] Performance of a flat-panel detector in the detection of artificial erosive changes: comparison with conventional screen-film and storage-phosphor radiography
    Karl Ludwig
    Andreas Henschel
    Thomas M. Bernhardt
    Horst Lenzen
    Dag Wormanns
    Stefan Diederich
    Walter Heindel
    [J]. European Radiology, 2003, 13 : 1316 - 1323
  • [4] Detection of subtle undisplaced rib fractures in a porcine model:: Radiation dose requirement -: Digital flat-panel versus screen-film and storage-phosphor systems
    Ludwig, K
    Schülke, C
    Diederich, S
    Wormanns, D
    Lenzen, H
    Bernhardt, TM
    Brinckmann, P
    Heindel, W
    [J]. RADIOLOGY, 2003, 227 (01) : 163 - 168
  • [5] Performance of a flat-panel detector in the detection of artificial erosive changes: comparison with conventional screen-film and storage-phosphor radiography
    Ludwig, K
    Henschel, A
    Bernhardt, TM
    Lenzen, H
    Wormanns, D
    Diederich, S
    Heindel, W
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (06) : 1316 - 1323
  • [6] Performance of a new digital flat-panel detector system in the detection of simulated rheumathoid erosions: A comparison with a speed class 200 screen-film system, a mammography screen-film system and a storage-phosphor system at different levels of exposure
    Ludwig, K
    Henschel, A
    Bernhardt, T
    Lenzen, H
    Wormanns, D
    Diederich, S
    Heindel, W
    [J]. MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 423 - 426
  • [7] Flat-panel digital mammography system: Contrast-detail comparison between screen-film radiographs and hard-copy images
    Suryanarayanan, S
    Karellas, A
    Vedantham, S
    Ved, H
    Baker, SP
    D'Orsi, CJ
    [J]. RADIOLOGY, 2002, 225 (03) : 801 - 807
  • [8] Digital amorphous silicon flat-panel detector vs screen-film and storage phosphor systems in chest imaging: Comparison of the entrance skin dose
    Smeets, PV
    Bacher, K
    Duyck, P
    Verstraete, KL
    Thierens, H
    [J]. RADIOLOGY, 2002, 225 : 382 - 382
  • [9] DETECTION OF SIMULATED CHEST LESIONS - COMPARISON OF A CONVENTIONAL SCREEN-FILM COMBINATION, AN ASYMMETRIC SCREEN-FILM SYSTEM, AND STORAGE PHOSPHOR RADIOGRAPHY
    LEPPERT, AGA
    PROKOP, M
    SCHAEFERPROKOP, CM
    GALANSKI, M
    [J]. RADIOLOGY, 1995, 195 (01) : 259 - 263
  • [10] Performance of a flat-panel detector system in the depiction of anatomic details of the lumbar spine in Cynomolgus Monkeys: Comparison to a screen-film and a storage-phosphor system using different exposure doses
    Ludwig, K
    Ahlers, K
    Diederich, S
    Bernhardt, TM
    Freund, M
    Heindel, WL
    [J]. RADIOLOGY, 2002, 225 : 642 - 642