Heterodyne Detection System for Nanoparticle Detection using Coherent Fourier Scatterometry

被引:1
|
作者
Kolenov, D. [1 ]
Horsten, R. C. [1 ]
Pereira, S. F. [1 ]
机构
[1] Delft Univ Technol, Fac Appl Sci, Imaging Phys Dept, Opt Res Grp, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
关键词
nanoparticle detection; heterodyne detection; coherent Fourier scatterometry; wafer inspection; PARTICLES;
D O I
10.1117/12.2525587
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Coherent Fourier Scatterometry (CFS) is a scanning optical technique that is particularly suitable for nanoparticle detection. Inspection of wafer surfaces is one of the critical bottle-necks for high yield in the production of semiconductor chips. Ideally, inspection systems are required to work fast, be sensitive, and should not thermally damage the samples with an excess of illuminating light power. The sensitivity of detection of nanoparticles, attributed to the smallest size of the scatterer that can be detected, is severely limited by noise. The optical readout of the scatterometer consists of a bi-cell (a split photodetector) that collects the scatterred light from the surface to be inspected while the latter is scanned in the lateral direction (2D scan). The difference voltage signal resulting from integrating and subtracting the two halves of the bi-cell is recorded as a function of the lateral scanning position of the sample surface. The bi-cell has two functions: first, it allows us to acquire signals in a fast manner, and second, it eliminates effects due to substrate spurious reflections, which is usually a big issue in dark field based particle detection systems. In this paper, we present an extension of the original CFS detection system by incorporating a heterodyne technique to the detection system. We show the implementation of the new detector system as well as a comparative signal-to-noise ratio (SNR) gain studies that are used to determine the suitable frequencies and waveforms for both modulation and reference signals. We demonstrate the detection of polystyrene nanoparticles with a diameter of 80 nm, which were deposited on top of a silicon wafer, with high SNR at low illuminating light power. The experiments were performed with a diode laser at the wavelength of 405 nm. In this particular particle size, we have observed an improvement of the SNR of about 45 dB as compared to the original detection system of the CFS. Although the proposed heterodyne CFS technique already shows excellent performance for detection of polystyrene nanoparticles on silicon wafer, there is still room for improving the sensitivity towards even smaller particles, as discussed in the outlook and conclusions section.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Determination of the full scattering matrix using coherent Fourier scatterometry
    Kumar, Nitish
    Cisotto, Luca
    Roy, Sarathi
    Ramanandan, Gopika K. P.
    Pereira, Silvania F.
    Urbach, H. Paul
    APPLIED OPTICS, 2016, 55 (16) : 4408 - 4413
  • [22] Phase information in Coherent Fourier Scatterometry
    Kumar, N.
    El Gawhary, O.
    Roy, S.
    Pereira, S. F.
    Urbach, H. P.
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION VIII, 2013, 8788
  • [23] The performance of heterodyne detection system for partially coherent beams in turbulent atmosphere
    Li Chengqiang
    Wang Tingfeng
    Zhang Heyong
    Xie Jingjiang
    Liu Lisheng
    Zhao Shuai
    Guo Jin
    OPTICS COMMUNICATIONS, 2015, 356 : 620 - 627
  • [24] Coherent heterodyne detection system for high-resolution BSDF measurements
    Neubert, J
    Schulz, U
    OPTICAL SYSTEM CONTAMINATION V AND STRAY LIGHT AND SYSTEM OPTIMIZATION, 1996, 2864 : 322 - 332
  • [25] Retrodiction for coherent communication with homodyne or heterodyne detection
    Jedrkiewicz, O.
    Loudon, R.
    Jeffers, J.
    EUROPEAN PHYSICAL JOURNAL D, 2006, 39 (01): : 129 - 140
  • [26] Frequency noise measurements using coherent self-heterodyne detection
    Thomsen, Simon Thorndahl
    Brusatori, Monica Far
    Arent, Niklas Hedegaard
    Kumar, Rakesh Ranjan
    Volet, Nicolas
    OPTICS LETTERS, 2023, 48 (24) : 6372 - 6375
  • [27] OPTICAL CHARACTERISTICS OF DENTIN USING COHERENT HETERODYNE-DETECTION TECHNIQUE
    ISHIHATA, H
    DEVARAJ, B
    KOBAYASHI, M
    USA, M
    INABA, H
    HORIUCHI, H
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 423 - 423
  • [28] FULLY QUANTIZED THEORY OF COHERENT HETERODYNE DETECTION
    VANSTRYL.EW
    SCULLY, MO
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1974, QE10 (09) : 692 - 692
  • [29] The reduction of the LO number for heterodyne coherent detection
    Li, Xinying
    Yu, Jianjun
    Chi, Nan
    Dong, Ze
    Zhang, Junwen
    Yu, Jianguo
    OPTICS EXPRESS, 2012, 20 (28): : 29613 - 29619
  • [30] Retrodiction for coherent communication with homodyne or heterodyne detection
    O. Jedrkiewicz
    R. Loudon
    J. Jeffers
    The European Physical Journal D - Atomic, Molecular, Optical and Plasma Physics, 2006, 39 : 129 - 140