Evaluation of sparing organs at risk (OARs) in left-breast irradiation in the supine and prone positions and with deep inspiration breath-hold

被引:17
|
作者
Saini, Amitpal Singh [1 ,2 ]
Hwang, Catherine S. [2 ]
Biagioli, Matthew C. [2 ]
Das, Indra J. [3 ]
机构
[1] Univ S Florida, Det Med Engn, Tampa, FL 33620 USA
[2] Florida Hosp Med Ctr, Dept Radiat Oncol, 601 E Rollins St, Orlando, FL 32803 USA
[3] Laura & Isaac Perlmutter Canc Ctr, NYU Langone Med Ctr, Dept Radiat Oncol, New York, NY USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2018年 / 19卷 / 04期
关键词
cardiac toxicity; deep inspiration breath-hold; heart dose; LAD dose; left ventricle dose; Lt breast radiation; lung dose; prone position; supine position; CANCER RADIOTHERAPY; HEART-DISEASE; LUNG-CANCER; COMPLICATION PROBABILITIES; ADAPTED RADIOTHERAPY; RADIATION-THERAPY; CORONARY-ARTERY; WOMEN; WHOLE; MORTALITY;
D O I
10.1002/acm2.12382
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare doses to organs at risk (OARs) for left-sided whole-breast radiation therapy with comparable planning target volume (PTV) coverage using three techniques: free breathing in a supine position (SFB), deep inspirational breath-hold in a supine position (SDIBH), and free breathing in prone position (PFB). Materials and methods: Thirty-three patients with left-sided early-stage breast cancer underwent CT simulation following SFB, SDIBH, and PFB protocols for whole-breast radiation therapy. One radiation oncologist contoured the breast PTV, heart, left ventricle (LV), and left anterior descending artery (LAD). Treatment plans were optimized using field-in-field technique with the AAA algorithm. Each plan was optimized to provide identical coverage to the PTV such that a reasonable comparison for OAR dosimetry could be evaluated. All plans were prescribed 42.56 Gy in 16 fractions to the left-breast PTV. Results: The mean dose in SFB for the heart, LV, and LAD was 1.92, 3.19, and 21.73 Gy, respectively, which were significantly higher than the mean dose in SDIBH for the heart (1.08 Gy, P <= 0.0001), LV (1.50 Gy, P <= 0.0001), and LAD (6.3 Gy, P <= 0.0001) and in PFB for the heart (0.98 Gy, P <= 0.0001), LV (1.34 Gy, P <= 0.0001), and LAD (6.57 Gy, P <= 0.0001). Similar findings were noted for the cardiac components in SFB for V2.5, V5, V10, V20, and V30 compared with values in SDIBH and PFB. The mean dose for the left lung in PFB was 0.61 Gy that was significantly lower than in SFB (5.63 Gy, P <= 0.0001) and SDIBH (5.54 Gy, P <= 0.0001). Mean dose and dosimetric values for each OAR increased in SFB and SDIBH for patients with a large breast volume compared with values for patients with a small breast volume. Conclusions: SFB results in higher heart, LAD, and LV doses than the other techniques. Both PFB and SDIBH are more advantageous for these OARs irrespective of breast volume. PFB results in significantly lower lung doses than SFB and SDIBH. PFB always provided better results than SFB for the heart, LV, LAD, and lung. This conclusion contrasts with some published studies concluding that the prone position has no benefit for heart sparing.
引用
收藏
页码:195 / 204
页数:10
相关论文
共 50 条
  • [41] The effect of deep inspiration breath-hold technique on left anterior descending coronary artery and heart dose in left breast irradiation
    Sakyanun, Pitchaya
    Saksornchai, Kitwadee
    Nantavithya, Chonnipa
    Chakkabat, Chakkapong
    Shotelersuk, Kanjana
    RADIATION ONCOLOGY JOURNAL, 2020, 38 (03): : 181 - 188
  • [42] A simplified frame work using deep inspiration breath-hold (DIBH) for the treatment of left breast cancer with improved heart sparing
    Guan, H.
    Wen, N.
    Pradhan, D.
    Dong, H.
    Hammoud, R.
    Li, S.
    Movsas, B.
    MEDICAL PHYSICS, 2006, 33 (06) : 2062 - 2062
  • [43] Prone breast radiotherapy in prone: free breathing, deep inspiration breath hold and inspiration gating
    Swimberge, M.
    Remouchamps, V.
    Veldeman, L.
    Mulliez, T.
    Speelers, B.
    Clermont, C.
    Sergent, F.
    De Neve, W.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S710 - S710
  • [44] The effect of moderate deep inspiration breath hold on heart dose for prone left-sided whole breast irradiation
    Mulliez, T.
    Veldeman, L.
    Speleers, B.
    Mahjoubi, K.
    Remouchamps, V.
    Van Greveling, A.
    Gilsoul, M.
    Berwouts, D.
    Lievens, Y.
    De Neve, W.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S197 - S197
  • [45] Modeled risk of ischemic heart disease following left breast irradiation with deep inspiration breath hold
    Eldredge-Hindy, Harriet B.
    Duffy, Danielle
    Yamoah, Kosj
    Simone, Nicole L.
    Skowronski, Jenna
    Dicker, Adam P.
    Anne, Pramila R.
    PRACTICAL RADIATION ONCOLOGY, 2015, 5 (03) : 162 - 168
  • [46] Towards Quantitative Clinical Decision On Deep Inspiration Breath Hold (DIBH) Or Prone for Left-Sided Breast Irradiation
    Lin, H.
    Gao, Y.
    Liu, T.
    Gelblum, D.
    Ho, A.
    Powell, S.
    Tang, X.
    Xu, X.
    MEDICAL PHYSICS, 2015, 42 (06) : 3529 - 3530
  • [47] A simple and low-cost method of deep inspiration breath-hold irradiation for breast cancer
    Koide, Y.
    Kitagawa, T.
    Aoyama, T.
    Shimizu, H.
    Tanaka, H.
    Tachibana, H.
    Kodaira, T.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1070 - S1070
  • [48] Deep inspiration Breath Hold: Techniques and Advantages for Cardiac Sparing During Breast Cancer Irradiation
    Bergom, Carmen
    Currey, Adam
    Desai, Nina
    Tai, An
    Strauss, Jonathan B.
    FRONTIERS IN ONCOLOGY, 2018, 8
  • [49] Should DIBH (deep inspiration breath-hold) be the standard of care in LBC (left breast cancer)?
    Garcia Alvarez, M. G.
    Peraza Fernandez, C.
    Rodrigues, C.
    Mateos Dominguez, M.
    Montijano Linde, M.
    Marrone, I.
    Tinoco Gil, L.
    Lopez Ramirez, E.
    ANNALS OF ONCOLOGY, 2020, 31 : S55 - S55
  • [50] Selection of patients with left breast cancer for Deep-Inspiration Breath-Hold Radiotherapy Technique
    Czeremszynska, B.
    Drozda, S.
    Gorzynski, M.
    Kepka, L.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S555 - S555