Evaluation of sparing organs at risk (OARs) in left-breast irradiation in the supine and prone positions and with deep inspiration breath-hold

被引:17
|
作者
Saini, Amitpal Singh [1 ,2 ]
Hwang, Catherine S. [2 ]
Biagioli, Matthew C. [2 ]
Das, Indra J. [3 ]
机构
[1] Univ S Florida, Det Med Engn, Tampa, FL 33620 USA
[2] Florida Hosp Med Ctr, Dept Radiat Oncol, 601 E Rollins St, Orlando, FL 32803 USA
[3] Laura & Isaac Perlmutter Canc Ctr, NYU Langone Med Ctr, Dept Radiat Oncol, New York, NY USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2018年 / 19卷 / 04期
关键词
cardiac toxicity; deep inspiration breath-hold; heart dose; LAD dose; left ventricle dose; Lt breast radiation; lung dose; prone position; supine position; CANCER RADIOTHERAPY; HEART-DISEASE; LUNG-CANCER; COMPLICATION PROBABILITIES; ADAPTED RADIOTHERAPY; RADIATION-THERAPY; CORONARY-ARTERY; WOMEN; WHOLE; MORTALITY;
D O I
10.1002/acm2.12382
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare doses to organs at risk (OARs) for left-sided whole-breast radiation therapy with comparable planning target volume (PTV) coverage using three techniques: free breathing in a supine position (SFB), deep inspirational breath-hold in a supine position (SDIBH), and free breathing in prone position (PFB). Materials and methods: Thirty-three patients with left-sided early-stage breast cancer underwent CT simulation following SFB, SDIBH, and PFB protocols for whole-breast radiation therapy. One radiation oncologist contoured the breast PTV, heart, left ventricle (LV), and left anterior descending artery (LAD). Treatment plans were optimized using field-in-field technique with the AAA algorithm. Each plan was optimized to provide identical coverage to the PTV such that a reasonable comparison for OAR dosimetry could be evaluated. All plans were prescribed 42.56 Gy in 16 fractions to the left-breast PTV. Results: The mean dose in SFB for the heart, LV, and LAD was 1.92, 3.19, and 21.73 Gy, respectively, which were significantly higher than the mean dose in SDIBH for the heart (1.08 Gy, P <= 0.0001), LV (1.50 Gy, P <= 0.0001), and LAD (6.3 Gy, P <= 0.0001) and in PFB for the heart (0.98 Gy, P <= 0.0001), LV (1.34 Gy, P <= 0.0001), and LAD (6.57 Gy, P <= 0.0001). Similar findings were noted for the cardiac components in SFB for V2.5, V5, V10, V20, and V30 compared with values in SDIBH and PFB. The mean dose for the left lung in PFB was 0.61 Gy that was significantly lower than in SFB (5.63 Gy, P <= 0.0001) and SDIBH (5.54 Gy, P <= 0.0001). Mean dose and dosimetric values for each OAR increased in SFB and SDIBH for patients with a large breast volume compared with values for patients with a small breast volume. Conclusions: SFB results in higher heart, LAD, and LV doses than the other techniques. Both PFB and SDIBH are more advantageous for these OARs irrespective of breast volume. PFB results in significantly lower lung doses than SFB and SDIBH. PFB always provided better results than SFB for the heart, LV, LAD, and lung. This conclusion contrasts with some published studies concluding that the prone position has no benefit for heart sparing.
引用
收藏
页码:195 / 204
页数:10
相关论文
共 50 条
  • [21] Dosimetric Comparison of Organs at Risk With Deep Inspiration Breath-Hold Versus Free Breathing for Left-Sided Breast Cancer
    Hunugundmath, S.
    Chintam, S.
    Darekar, K.
    Naik, V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E266 - E266
  • [22] Deep Inspiration Breath-Hold Technique in Women With Left-Sided Breast Cancer: An Analysis of OAR Sparing
    Register, S.
    Reis, I.
    Zhao, W.
    Takita, C.
    Amestoy, W.
    Wright, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S226 - S227
  • [23] Heart dose reduction by prone deep inspiration breath hold in left-sided breast irradiation
    Mulliez, Thomas
    Veldeman, Liv
    Speleers, Bruno
    Mahjoubi, Khalil
    Remouchamps, Vincent
    Van Greveling, Annick
    Gilsoul, Monique
    Berwouts, Dieter
    Lievens, Yolande
    Van den Broecke, Rudy
    De Neve, Wilfried
    RADIOTHERAPY AND ONCOLOGY, 2015, 114 (01) : 79 - 84
  • [24] deep inspiration breath-hold techniques for left-sided breast cancer
    Frassinelli, Luca
    Petrucci, Rachele
    Baroni, Simone
    Sardo, Anna
    Pugliatti, Cristina
    Padula, Nicola
    Lucio, Francesco
    Reali, Alessia
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S655 - S656
  • [25] DIBH (Deep Inspiration Breath-Hold) in left breast radiotherapy -institutional experience
    Dzhugashvili, M.
    Montijano, M.
    Sevilla, B.
    Peraza, C.
    Fernandez, J.
    Gonsalves, D.
    Guijarro, M.
    Lopez, E.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1818 - S1818
  • [26] Clinical Implementation of Deep Inspiration Breath-Hold for Left Breast Cancers Treatment
    Jiang, R.
    Zhan, L.
    Gopaul, D.
    Osei, E.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [27] Evaluating Radiation Dose to the Heart With Left Whole Breast Radiation Therapy in Prone, Supine Breath-Hold, and Supine Free-Breathing Positions
    Perez, B. A.
    Patel, P. R.
    Yoo, S.
    O'Neill, L.
    Livengood, K. P.
    Catalano, S.
    Chollet, C. T.
    Blitzblau, R. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S229 - S229
  • [28] Cardiac dose-sparing effects of deep-inspiration breath-hold in left breast irradiation: Is IMRT more beneficial than VMAT?
    Sakka, M.
    Kunzelmann, L.
    Grabenbauer, G. G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 : S73 - S73
  • [29] Reproducibility and stability of spirometer-guided deep inspiration breath-hold in left-breast treatments using an optical surface monitoring system
    Cilla, Savino
    Romano, Carmela
    Craus, Maurizio
    Viola, Pietro
    Macchia, Gabriella
    Boccardi, Mariangela
    De Vivo, Livia P.
    Buwenge, Milly
    Morganti, Alessio G.
    Deodato, Francesco
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (06):
  • [30] Deep inspiration breath-hold radiotherapy for left-sided breast cancer after conserving surgery: A dose reduction for organs at risk
    Jaros, Drazan
    Kolarevic, Goran
    Savanovic, Milovan
    Maric, Slavica
    VOJNOSANITETSKI PREGLED, 2020, 77 (12) : 1271 - 1276