One-pot facile fabrication of graphene-zinc oxide composite and its enhanced sensitivity for simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid

被引:295
|
作者
Zhang, Xuan [1 ]
Zhang, Yi-Chi [1 ]
Ma, Li-Xia [1 ]
机构
[1] Donghua Univ, Coll Chem Chem Engn & Biotechnol, Shanghai 201620, Peoples R China
关键词
Graphene Zinc oxide; Ascorbic acid; Dopamine; Uric acid; Electrochemical biosensor; GLASSY-CARBON ELECTRODE; ULTRAFAST REDUCTION; CHEMICAL-REDUCTION; GRAPHITE OXIDE; SENSORS; NANOSTRUCTURES; NANOCOMPOSITE; NANOMATERIALS; NANOSHEETS; POWDER;
D O I
10.1016/j.snb.2015.12.073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reduced graphene oxide-zinc oxide (RGO-ZnO) composite was facilely fabricated by a spontaneous reduction of graphene oxide via zinc slice in one-pot approach at room temperature, and used to modify glassy carbon electrode (GCE) for developing of electrochemical biosensor (RGO-ZnO/GCE). The as-prepared RGO-ZnO was characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), inductively coupled plasma atomic emission spectroscopy (ICP-AES), scanning electron microscopy (SEM) and transmission electron microscope (TEM). It was revealed that the existence of ZnO in RGO-ZnO/GCE largely enhanced the electroactive surface area (EASA) and therefore the sensitivity for electrochemical sensing. In the mixtures of ascorbic acid (AA), dopamine (DA) and uric acid (UA), the biosensor exhibited three well-resolved voltammetric peaks (Delta EAA-DA= 236 mV, Delta EDA-UA = 132 mV, Delta EAA-UA = 368 mV) in the differential pulse voltammetry (DPV) measurements, allowing a simultaneous electrochemical detection of these biomolecules. The liner relationships between current intensities and concentrations were found to be 50-2350 mu M, 1-70 mu M and 3-330 mu M, with detection limits of 3.71 mu M, 0.33 mu M and 1.08 mu M for AA, UA and DA, respectively. The as-prepared RGO-ZnO/GCE biosensor displayed a good reproducibility and stability and was applied for detection of of AA, DA and UA in real plasma and urine samples with satisfying results. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:488 / 496
页数:9
相关论文
共 50 条
  • [31] Graphene-Based Flexible Sensors for Simultaneous Detection of Ascorbic Acid, Dopamine, and Uric Acid
    Meng, Shuaishuai
    Liu, Yaming
    Wang, Li
    Ji, Xixi
    Chen, Yun
    Zheng, Tingting
    Yu, Jie
    Feng, Huanhuan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [32] Noncovalent nanohybrid of cobalt tetraphenylporphyrin with graphene for simultaneous detection of ascorbic acid, dopamine, and uric acid
    Deng, Keqin
    Zhou, Jianhong
    Li, Xiaofang
    ELECTROCHIMICA ACTA, 2013, 114 : 341 - 346
  • [33] Facile synthesis of graphene hybrid tube-like structure for simultaneous detection of ascorbic acid, dopamine, uric acid and tryptophan
    Zhang, Wen
    Chai, Yaqin
    Yuan, Ruo
    Chen, Shihong
    Han, Jing
    Yuan, Dehua
    ANALYTICA CHIMICA ACTA, 2012, 756 : 7 - 12
  • [34] Synthesis of cobalt phosphide hybrid for simultaneous electrochemical detection of ascorbic acid, dopamine, and uric acid
    Xu, Hongyan
    Hang, Yulu
    Lei, Xiaoyu
    Deng, Jinan
    Yang, Jun
    RSC ADVANCES, 2024, 14 (21) : 14665 - 14671
  • [35] Simultaneous and sensitive determination of ascorbic acid, dopamine and uric acid via an electrochemical sensor based on PVP-graphene composite
    Yiyong Wu
    Peihong Deng
    Yaling Tian
    Jinxia Feng
    Jingyun Xiao
    Junhua Li
    Jun Liu
    Guangli Li
    Quanguo He
    Journal of Nanobiotechnology, 18
  • [36] Simultaneous and sensitive determination of ascorbic acid, dopamine and uric acid via an electrochemical sensor based on PVP-graphene composite
    Wu, Yiyong
    Deng, Peihong
    Tian, Yaling
    Feng, Jinxia
    Xiao, Jingyun
    Li, Junhua
    Liu, Jun
    Li, Guangli
    He, Quanguo
    JOURNAL OF NANOBIOTECHNOLOGY, 2020, 18 (01)
  • [37] Fabrication of reduced graphene oxide-bimetallic PdAu nanocomposites for the electrochemical determination of ascorbic acid, dopamine, uric acid and rutin
    Zou, Cui'e
    Zhong, Jiatai
    Li, Shin
    Wang, Huiwen
    Wang, Jin
    Yan, Bo
    Du, Yukou
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 805 : 110 - 119
  • [38] Electrochemical sensor based on nitrogen doped graphene: Simultaneous determination of ascorbic acid, dopamine and uric acid
    Sheng, Zhen-Huan
    Zheng, Xiao-Qing
    Xu, Jian-Yun
    Bao, Wen-Jing
    Wang, Feng-Bin
    Xia, Xing-Hua
    BIOSENSORS & BIOELECTRONICS, 2012, 34 (01): : 125 - 131
  • [39] A novel electrochemical biosensor based on hemin functionalized graphene oxide sheets for simultaneous determination of ascorbic acid, dopamine and uric acid
    Zou, Hao Lin
    Li, Bang Lin
    Luo, Hong Qun
    Li, Nian Bing
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 535 - 541
  • [40] Electrochemical sensor based on a nanocomposite prepared from TmPO4 and graphene oxide for simultaneous voltammetric detection of ascorbic acid, dopamine and uric acid
    Haiping Huang
    Yafeng Yue
    Zhongzhen Chen
    Yanan Chen
    Shuzhen Wu
    Jinsheng Liao
    Suijun Liu
    He-rui Wen
    Microchimica Acta, 2019, 186