One-pot facile fabrication of graphene-zinc oxide composite and its enhanced sensitivity for simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid

被引:282
|
作者
Zhang, Xuan [1 ]
Zhang, Yi-Chi [1 ]
Ma, Li-Xia [1 ]
机构
[1] Donghua Univ, Coll Chem Chem Engn & Biotechnol, Shanghai 201620, Peoples R China
关键词
Graphene Zinc oxide; Ascorbic acid; Dopamine; Uric acid; Electrochemical biosensor; GLASSY-CARBON ELECTRODE; ULTRAFAST REDUCTION; CHEMICAL-REDUCTION; GRAPHITE OXIDE; SENSORS; NANOSTRUCTURES; NANOCOMPOSITE; NANOMATERIALS; NANOSHEETS; POWDER;
D O I
10.1016/j.snb.2015.12.073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reduced graphene oxide-zinc oxide (RGO-ZnO) composite was facilely fabricated by a spontaneous reduction of graphene oxide via zinc slice in one-pot approach at room temperature, and used to modify glassy carbon electrode (GCE) for developing of electrochemical biosensor (RGO-ZnO/GCE). The as-prepared RGO-ZnO was characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), inductively coupled plasma atomic emission spectroscopy (ICP-AES), scanning electron microscopy (SEM) and transmission electron microscope (TEM). It was revealed that the existence of ZnO in RGO-ZnO/GCE largely enhanced the electroactive surface area (EASA) and therefore the sensitivity for electrochemical sensing. In the mixtures of ascorbic acid (AA), dopamine (DA) and uric acid (UA), the biosensor exhibited three well-resolved voltammetric peaks (Delta EAA-DA= 236 mV, Delta EDA-UA = 132 mV, Delta EAA-UA = 368 mV) in the differential pulse voltammetry (DPV) measurements, allowing a simultaneous electrochemical detection of these biomolecules. The liner relationships between current intensities and concentrations were found to be 50-2350 mu M, 1-70 mu M and 3-330 mu M, with detection limits of 3.71 mu M, 0.33 mu M and 1.08 mu M for AA, UA and DA, respectively. The as-prepared RGO-ZnO/GCE biosensor displayed a good reproducibility and stability and was applied for detection of of AA, DA and UA in real plasma and urine samples with satisfying results. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:488 / 496
页数:9
相关论文
共 50 条
  • [21] Synergistic electrocatalytic effect of graphene/nickel hydroxide composite for the simultaneous electrochemical determination of ascorbic acid, dopamine and uric acid
    Nancy, T. E. Mary
    Kumary, V. Anitha
    ELECTROCHIMICA ACTA, 2014, 133 : 233 - 240
  • [22] Facile synthesis of porous bimetallic alloyed PdAg nanoflowers supported on reduced graphene oxide for simultaneous detection of ascorbic acid, dopamine, and uric acid
    Chen, Li-Xian
    Zheng, Jie-Ning
    Wang, Ai-Jun
    Wu, Lan-Ju
    Chen, Jian-Rong
    Feng, Jiu-Ju
    ANALYST, 2015, 140 (09) : 3183 - 3192
  • [23] Graphitic carbon nitride nanosheets doped graphene oxide for electrochemical simultaneous determination of ascorbic acid, dopamine and uric acid
    Zhang, Hanqiang
    Huang, Qitong
    Huang, Yihong
    Li, Feiming
    Zhang, Wuxiang
    Wei, Chan
    Chen, Jianhua
    Dai, Pingwang
    Huang, Lizhang
    Huang, Zhouyi
    Kang, Lianping
    Hu, Shirong
    Hao, Aiyou
    Electrochimica Acta, 2014, 142 : 125 - 131
  • [24] Graphitic carbon nitride nanosheets doped graphene oxide for electrochemical simultaneous determination of ascorbic acid, dopamine and uric acid
    Zhang, Hanqiang
    Huang, Qitong
    Huang, Yihong
    Li, Feiming
    Zhang, Wuxiang
    Wei, Chan
    Chen, Jianhua
    Dai, Pingwang
    Huang, Lizhang
    Huang, Zhouyi
    Kang, Lianping
    Hu, Shirong
    Hao, Aiyou
    ELECTROCHIMICA ACTA, 2014, 142 : 125 - 131
  • [25] The simultaneous electrochemical detection of ascorbic acid, dopamine, and uric acid using graphene/size-selected Pt nanocomposites
    Sun, Chia-Liang
    Lee, Hsin-Hsien
    Yang, Jen-Ming
    Wu, Ching-Chou
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (08): : 3450 - 3455
  • [26] Simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid based on graphene anchored with Pd-Pt nanoparticles
    Yan, Jun
    Liu, Shi
    Zhang, Zhenqin
    He, Guangwu
    Zhou, Ping
    Liang, Haiying
    Tian, Lulu
    Zhou, Xuemin
    Jiang, Huijun
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 111 : 392 - 397
  • [27] Boron and Nitrogen Doped Graphene via Microwave Exfoliation for Simultaneous Electrochemical Detection of Ascorbic Acid, Dopamine and Uric Acid
    Thearle, Rozi Alice
    Latiff, Naziah Mohamad
    Sofer, Zdenek
    Mazanek, Vlastimil
    Pumera, Martin
    ELECTROANALYSIS, 2017, 29 (01) : 45 - 50
  • [28] Simultaneous Detection of Ascorbic Acid, Dopamine, and Uric Acid Using a Novel Electrochemical Sensor Based on Palladium Nanoparticles/Reduced Graphene Oxide Nanocomposite
    Wei, Yuyun
    Liu, Yangyang
    Xu, Zhifang
    Wang, Shenjun
    Chen, Bo
    Zhang, Di
    Fang, Yuxin
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 2020
  • [29] Graphene-Palladium Composite for the Simultaneous Electrochemical Determination of Epinephrine, Ascorbic acid and Uric Acid
    Renjini, S.
    Abraham, Pinky
    Aparna, S.
    Kumary, Anitha, V
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (14) : B1321 - B1329
  • [30] Graphene-Based Flexible Sensors for Simultaneous Detection of Ascorbic Acid, Dopamine, and Uric Acid
    Meng, Shuaishuai
    Liu, Yaming
    Wang, Li
    Ji, Xixi
    Chen, Yun
    Zheng, Tingting
    Yu, Jie
    Feng, Huanhuan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9