Comparison of measurements of neuroretinal rim area between confocal laser scanning tomography and planimetry of photographs

被引:46
|
作者
Jonas, JB
Mardin, CY
Gründler, AE
机构
[1] Univ Erlangen Nurnberg, Augenklin, Dept Ophthalmol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Hosp Eye, D-91054 Erlangen, Germany
关键词
D O I
10.1136/bjo.82.4.362
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background-To compare neuroretinal rim area measurements by confocal scanning laser tomography and planimetric evaluation of optic disc photographs. Methods-For 221 patients with primary and secondary open angle glaucoma, 72 subjects with ocular hypertension, and 139 normal subjects, the optic disc was morphometrically analysed by the confocal scanning laser tomograph HRT (Heidelberg retina tomograph) and by planimetric evaluation of stereo colour optic disc photographs. Results-Absolute rim area and rim to disc area were significantly (p<0.0001) larger with the HRT than with planimetric evaluation of photographs. Differences between the two methods were significantly (p<0.01) larger in normal eyes with small cupping than in normal eyes with large cupping, and differences were significantly (p<0.01) larger in glaucomatous eyes with marked nerve damage than in glaucomatous eyes with moderate nerve damage. Coefficients of correlations between rim measurements of both methods were R-2=0.60 for rim to disc area and R-2=0.33 for absolute rim area. Planimetric measurements of rim area correlated significantly (p<0.05) better than HRT determinations of rim area with mean visual field defect and retinal nerve fibre layer visibility. Conclusions-Measurements of absolute rim area and rim to disc area are significantly larger with the HRT compared with planimetry of disc photographs. Differences between both methods depend on disc area, cup size and glaucoma stage. The reason may be that the HRT measures the retinal vessel trunk as part of the neuroretinal rim. The differences between both methods, which should be taken into account if disc measurements performed by both methods are compared with each other, may not influence the main advantage of the HRT-that is, morphological follow up examination of patients with glaucoma.
引用
收藏
页码:362 / 366
页数:5
相关论文
共 50 条
  • [41] Effect of Trabeculectomy on Optical Coherence Tomography (OCT) Measurements of the optic nerve head Neuroretinal Rim Tissue
    Moon, Jessica
    Gardiner, Stuart Keith
    Fortune, Brad
    Reynaud, Juan
    Mansberger, Steven L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [42] Comparison of the test-retest variability of neuroretinal rim area measurements in normal and glaucoma patients using RTA and OCT3
    Shewry, JM
    Ikeji, FC
    White, ET
    Schlottmann, PG
    Garway-Heath, DF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [43] Effect of acute intraocular pressure reduction on optic nerve head tomography. A comparison between confocal scanning laser tomography and conventional photography
    Orr, AC
    Chauhan, BC
    Levy, DM
    LeBlanc, RP
    Rafuse, PE
    McCormick, TA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3864 - 3864
  • [44] Measurements Validating the Confocal Scanning Laser Holography Microscope
    Jacquemin, Peter B.
    Herring, Rodney A.
    MICROSCOPY AND MICROANALYSIS, 2011, 17 (04) : 618 - 623
  • [45] CONFOCAL LASER SCANNING OPHTHALMOSCOPE - REPRODUCIBILITY OF OPTIC-NERVE HEAD TOPOGRAPHIC MEASUREMENTS WITH THE CONFOCAL LASER SCANNING OPHTHALMOSCOPE
    CIOFFI, GA
    ROBIN, AL
    EASTMAN, RD
    PERELL, HF
    SAFARAZI, FA
    KELMAN, SE
    OPHTHALMOLOGY, 1993, 100 (01) : 57 - 62
  • [46] Diagnostic laser in glaucoma:: scanning laser polarimetry (GDx VCC) and confocal scanning laser tomography (HRT)
    Renard, JP
    Giraud, JM
    May, F
    Rigal-Sastourné, JC
    Oubaaz, A
    Reda, K
    Maurin, JF
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2005, 28 (02): : 177 - 184
  • [47] Comparison of optic nerve head measurement by optical coherence tomography and confocal scanning laser ophthalmoscope
    Kee, C
    Yong, PC
    Taek, KY
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U109 - U109
  • [48] Optical Coherence Tomography Angiography in Mice: Comparison with Confocal Scanning Laser Microscopy and Fluorescein Angiography
    Giannakaki-Zimmermann, Helena
    Kokona, Despina
    Wolf, Sebastian
    Ebneter, Andreas
    Zinkernagel, Martin S.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2016, 5 (04):
  • [49] Retinal vasculature in mice: A comparison of optical coherence tomography angiography and confocal scanning laser microscopy
    Zimmermann, Helena
    Kokona, Despina
    Wolf, Sebastian
    Ebneter, Andreas
    Zinkernagel, Martin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [50] In vivo imaging of human skin: A comparison of optical coherence tomography and confocal laser scanning microscopy
    Neerken, S
    Lucassen, GW
    Lenderink, E
    Nuijs, T
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VII, 2003, 4956 : 299 - 306