Single centre experience of hypothermic machine perfusion of kidneys from extended criteria deceased heart-beating donors: a comparative study

被引:10
|
作者
Forde, J. C. [1 ,2 ]
Shields, W. P. [1 ]
Azhar, M. [1 ]
Daly, P. J. [1 ]
Zimmermann, J. A. [1 ]
Smyth, G. P. [1 ]
Eng, M. P. [1 ]
Power, R. E. [1 ]
Mohan, P. [1 ]
Hickey, D. P. [1 ]
Little, D. M. [1 ]
机构
[1] Beaumont Hosp, Natl Kidney & Pancreas Transplantat Unit, Dublin 9, Ireland
[2] Beaumont Hosp, Dept Urol & Transplantat, Dublin 9, Ireland
关键词
Extended criteria donor; Hypothermic machine perfusion; Kidney transplant; Outcome; COLD-STORAGE; TRANSPLANTATION; PRESERVATION; RECIPIENTS; ALLOGRAFTS; SURVIVAL; DONATION; IMPACT; GRAFT; DEATH;
D O I
10.1007/s11845-014-1235-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Kidneys from extended criteria donors are associated with higher rates of delayed graft function (DGF). Hypothermic machine perfusion (MP) for storage is associated with more favourable outcomes. Methods A retrospective analysis was performed in 93 patients where the kidney was stored using hypothermic MP (LifePort (R)) and compared to an age-matched control group where the kidney was stored in cold static storage (CSS) using University of Wisconsin solution. Results Median age was similar in both groups (59.2 years in MP vs 59.9 years in CSS, p = 0.5598). Mean cold storage time was 15.6 h in MP vs 17.9 h in CSS. Post transplant mean serum creatinine was as follows; MP group-144.7 mu mol/L at 1 month; 138.3 mu mol/L at 3 months and 129.5 mu mol/L at 12 months. In the CSS group-163 mu mol/L at 1 month; 154.9 mu mol/L at 3 months and 140.2 mu mol/L at 12 months. There was a statistically significant difference at 1 month (p = 0.0096) and 3 months (p = 0.0236). DGF was defined as the need for haemodialysis within 7 days post transplant. In the MP group, DGF occurred in 17.2 % patients with mean of 6 days (range 1-18). In the CSS group, 25.8 % patients with mean of 8.1 days (range 3-25). One-year graft survival rate was better in the MP group (97.85 vs 96.77 %). Conclusion Our experience to date recommends the use of hypothermic MP for storage of kidneys from extended criteria deceased heart-beating donors.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 50 条
  • [41] EFFECTIVENESS OF MACHINE PERFUSION PRESERVATION AS A VIABILITY DETERMINATION METHOD FOR KIDNEYS PROCURED FROM NON-HEART-BEATING DONORS
    MATSUNO, N
    SAKURAI, E
    TAMAKI, I
    FURUHASHI, K
    SAITO, A
    ZHANG, S
    KOZAKI, K
    SHIMADA, A
    MIYAMOTO, K
    KOZAKI, M
    TRANSPLANTATION PROCEEDINGS, 1994, 26 (04) : 2421 - 2422
  • [42] ANALYSIS OF MACHINE PERFUSION PARAMETERS OF KIDNEYS PROCURED FROM EXPANDED CRITERIA DONORS
    Domagala, Piotr
    Kwiatkowski, Artur
    Wszola, Michal
    Kasprzyk, Tomasz
    Fesolowicz, Slawomir
    Kulik, Agnieszka
    Ostrowski, Krzyszof
    Chmura, Andrzej
    TRANSPLANT INTERNATIONAL, 2009, 22 : 56 - 57
  • [43] Hypothermic Machine Perfusion Ameliorates Ischemia-Reperfusion Injury in Rat Lungs From Non-Heart-Beating Donors
    Nakajima, Daisuke
    Chen, Fengshi
    Yamada, Tetsu
    Sakamoto, Jin
    Osumi, Akihiro
    Fujinaga, Takuji
    Shoji, Tsuyoshi
    Sakai, Hiroaki
    Bando, Toru
    Date, Hiroshi
    TRANSPLANTATION, 2011, 92 (08) : 858 - 863
  • [44] Impact of Hypothermic Machine Perfusion on the Early Function of Kidneys from Donors after Cardiac Death
    Szabo, L.
    Asderakis, A.
    Cook, B.
    Ablorsu, E.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2012, 12 : 499 - 499
  • [45] Comparative study of outcome between deceased donor kidney transplantation using standard criteria vs expanded criteria donors: An experience from a single centre in Sri Lanka.
    Seneviratne, Lasantha
    Manikkage, Yasuni
    Rathnayake, Sajeeni
    Karunagoda, Randilla
    Wickramasekera, Chathuri
    Galahitiyawa, Chinthana
    Pilimatalawwe, Chamila
    TRANSPLANTATION, 2024, 108 (9S)
  • [46] Extracellular Vesicles Derived from Mesenchymal Stromal Cells Delivered during Hypothermic Oxygenated Machine Perfusion Repair Ischemic/Reperfusion Damage of Kidneys from Extended Criteria Donors
    Rampino, Teresa
    Gregorini, Marilena
    Germinario, Giuliana
    Pattonieri, Eleonora Francesca
    Erasmi, Fulvia
    Grignano, Maria Antonietta
    Bruno, Stefano
    Alomari, Esra
    Bettati, Stefano
    Asti, Annalia
    Ramus, Marina
    De Amici, Mara
    Testa, Giorgia
    Bruno, Stefania
    Ceccarelli, Gabriele
    Serpieri, Nicoletta
    Libetta, Carmelo
    Sepe, Vincenzo
    Blasevich, Flavia
    Odaldi, Federica
    Maroni, Lorenzo
    Vasuri, Francesco
    La Manna, Gaetano
    Ravaioli, Matteo
    BIOLOGY-BASEL, 2022, 11 (03):
  • [47] Comparative study of outcome between deceased donor kidney transplantation using standard criteria vs expanded criteria donors: An experience from a single centre in Sri Lanka.
    Seneviratne, Lasantha
    Manikkage, Yasuni
    Rathnayake, Sajeeni
    Karunagoda, Randilla
    Wickramasekera, Chathuri
    Galahitiyawa, Chinthana
    Pilimatalawwe, Chamila
    TRANSPLANTATION, 2024, 108 (09) : 537 - 537
  • [48] SINGLE CENTRE INITIAL EXPERIENCE OF HYPOTHERMIC ORGAN PERFUSION USING RM3 PERFUSION MACHINE
    Rizzello, Anna
    Hamaoui, Karim
    Mastoridis, Sotiris
    Crane, Jeremy
    Hakim, Nadey
    Taube, David
    Papalois, Vassilios
    TRANSPLANT INTERNATIONAL, 2013, 26 : 274 - 274
  • [49] THE EFFECT OF MACHINE PERFUSION PRESERVATION VERSUS COLD-STORAGE ON THE FUNCTION OF KIDNEYS FROM NON-HEART-BEATING DONORS
    MATSUNO, N
    SAKURAI, E
    TAMAKI, I
    UCHIYAMA, M
    KOZAKI, K
    KOZAKI, M
    TRANSPLANTATION, 1994, 57 (02) : 293 - 294
  • [50] Benefit of hypothermic oxygenated machine perfusion in liver transplantation with grafts from extended criteria Donors after Brain Death (DBD)
    Patrono, D.
    Catalano, G.
    Rizza, G.
    Surra, A. C.
    Salizzoni, M.
    Romagnoli, R.
    TRANSPLANTATION, 2019, 103 (08) : 51 - 51