Single centre experience of hypothermic machine perfusion of kidneys from extended criteria deceased heart-beating donors: a comparative study

被引:10
|
作者
Forde, J. C. [1 ,2 ]
Shields, W. P. [1 ]
Azhar, M. [1 ]
Daly, P. J. [1 ]
Zimmermann, J. A. [1 ]
Smyth, G. P. [1 ]
Eng, M. P. [1 ]
Power, R. E. [1 ]
Mohan, P. [1 ]
Hickey, D. P. [1 ]
Little, D. M. [1 ]
机构
[1] Beaumont Hosp, Natl Kidney & Pancreas Transplantat Unit, Dublin 9, Ireland
[2] Beaumont Hosp, Dept Urol & Transplantat, Dublin 9, Ireland
关键词
Extended criteria donor; Hypothermic machine perfusion; Kidney transplant; Outcome; COLD-STORAGE; TRANSPLANTATION; PRESERVATION; RECIPIENTS; ALLOGRAFTS; SURVIVAL; DONATION; IMPACT; GRAFT; DEATH;
D O I
10.1007/s11845-014-1235-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Kidneys from extended criteria donors are associated with higher rates of delayed graft function (DGF). Hypothermic machine perfusion (MP) for storage is associated with more favourable outcomes. Methods A retrospective analysis was performed in 93 patients where the kidney was stored using hypothermic MP (LifePort (R)) and compared to an age-matched control group where the kidney was stored in cold static storage (CSS) using University of Wisconsin solution. Results Median age was similar in both groups (59.2 years in MP vs 59.9 years in CSS, p = 0.5598). Mean cold storage time was 15.6 h in MP vs 17.9 h in CSS. Post transplant mean serum creatinine was as follows; MP group-144.7 mu mol/L at 1 month; 138.3 mu mol/L at 3 months and 129.5 mu mol/L at 12 months. In the CSS group-163 mu mol/L at 1 month; 154.9 mu mol/L at 3 months and 140.2 mu mol/L at 12 months. There was a statistically significant difference at 1 month (p = 0.0096) and 3 months (p = 0.0236). DGF was defined as the need for haemodialysis within 7 days post transplant. In the MP group, DGF occurred in 17.2 % patients with mean of 6 days (range 1-18). In the CSS group, 25.8 % patients with mean of 8.1 days (range 3-25). One-year graft survival rate was better in the MP group (97.85 vs 96.77 %). Conclusion Our experience to date recommends the use of hypothermic MP for storage of kidneys from extended criteria deceased heart-beating donors.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 50 条
  • [31] HYPOTHERMIC MACHINE PERFUSION MAY IMPROVE EX-SITU PRESERVATION OF LIVERS FROM EXTENDED CRITERIA DONORS
    Tran, Alexandria
    Sanchez-Garcia, Jorge
    Gagnon, Andrew
    Contreras, Alan G.
    Fujita, Shiro
    Zendejas, Ivan
    Fife, Megan
    Krong, Jake
    Rodriguez-Davalos, Manuel I.
    Alonso, Diane
    HEPATOLOGY, 2021, 74 : 836A - 836A
  • [32] Hypothermic machine perfusion of kidneys retrieved from standard and high-risk donors
    Jochmans, Ina
    O'Callaghan, John M.
    Pirenne, Jacques
    Ploeg, Rutger J.
    TRANSPLANT INTERNATIONAL, 2015, 28 (06) : 665 - 676
  • [33] Benefits of active oxygenation during hypothermic machine perfusion of kidneys in a preclinical model of deceased after cardiac death donors
    Thuillier, Raphael
    Allain, Geraldine
    Celhay, Olivier
    Hebrard, William
    Barrou, Benoit
    Badet, Lionel
    Leuvenink, Henri
    Hauet, Thierry
    JOURNAL OF SURGICAL RESEARCH, 2013, 184 (02) : 1174 - 1181
  • [34] Dual kidney transplant from extended criteria donors - a single-centre experience
    Hakeem, A.
    Raza, S.
    Sheridan, K.
    Menon, K.
    Ahmad, N.
    BRITISH JOURNAL OF SURGERY, 2012, 99 : 196 - 197
  • [35] Early experience with hypothermic machine perfusion of living donor kidneys - a retrospective study
    Moser, Michael A. J.
    Ginther, Nathan
    Luo, Yigang
    Beck, Gavin
    Ginther, Ronn
    Ewen, Marla
    Matsche-Neufeld, Rhianna
    Shoker, Ahmed
    Sawicki, Grzegorz
    TRANSPLANT INTERNATIONAL, 2017, 30 (07) : 706 - 712
  • [36] OUTCOME OF TRANSPLANTED KIDNEYS FROM EXTENDED CRITERIA DONORS PRESERVED ON PERFUSION MACHINES
    Assem, M.
    Provot, F.
    Bertrand, D.
    Westeel, F.
    Mazouz, H.
    Poulain, C.
    Jaureguy, M.
    Saint, F.
    Guerrot, D.
    Hazzan, M.
    Choukroun, G.
    TRANSPLANT INTERNATIONAL, 2017, 30 : 8 - 8
  • [37] SINGLE CENTRE EXPERIENCE OF HYPOTHERMIC ORGAN PERFUSION USING RM3 PERFUSION MACHINE
    Di Cocco, Pierpaolo
    Bellini, Irene
    Manolitsi, Olga
    Turner, Sam
    Dor, Frank
    Crane, Jeremy
    Herbert, Paul
    Muthusamy, Anand
    Papalois, Vassilios
    TRANSPLANT INTERNATIONAL, 2017, 30 : 503 - 503
  • [38] Single centre experience of hypothermic organ perfusion using Rm3 perfusion machine
    Di Cocco, P.
    Bellini, I.
    Dor, F.
    Crane, J.
    Papalois, V.
    BRITISH JOURNAL OF SURGERY, 2017, 104 : 81 - 81
  • [39] INSITU PERFUSION OF KIDNEYS FROM NON-HEART-BEATING DONORS - THE MAASTRICHT PROTOCOL
    BOOSTER, MH
    WIJNEN, RMH
    MING, Y
    VROEMEN, JPAM
    KOOTSTRA, G
    TRANSPLANTATION PROCEEDINGS, 1993, 25 (01) : 1503 - 1504
  • [40] Hypothermic Machine Perfusion of Kidneys Compensates for Extended Storage Time: A Single Intervention With a Significant Impact
    Kruszyna, Tomasz
    Richter, Piotr
    TRANSPLANTATION PROCEEDINGS, 2021, 53 (03) : 1085 - 1090