Comparison of different methods of estimating the effective dose and the ambient dose equivalent for neutrons from measured prompt gamma intensities

被引:1
|
作者
Udupi, Ashwini [1 ]
Shetty, Pramoda Kumara [1 ]
Panikkath, Priyada [2 ]
Sarkar, Pradip Kumar [3 ]
机构
[1] Manipal Acad Higher Educ, Manipal Inst Technol, Dept Phys, Manipal 576104, Karnataka, India
[2] Alagappa Univ, Dept Phys, Karaikkudi 630004, Tamil Nadu, India
[3] Manipal Acad Higher Educ, Manipal Ctr Nat Sci, Manipal 576104, Karnataka, India
关键词
Neutron dose estimation; Ambient dose equivalent; Effective dose; Prompt gamma; Monte Carlo simulations; POLYETHYLENE;
D O I
10.1016/j.nima.2021.165072
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Estimations of the ambient dose equivalent H*(10) and the effective dose (anterior-posterior) E-AP from prompt gamma intensities are investigated theoretically using Monte Carlo simulations. The system considered consists of a NaI(Tl) gamma detector to measure prompt gamma intensities emitted due to neutron irradiation from a high density polyethylene (HDPE) cylinder embedded in a hollow borated-HDPE cylinder and covered by a layer of lead. A comparative evaluation of different computational techniques of dose estimation, such as, the multiple linear regression method, the detector response-matrix inversion method and the convolution of the unfolded neutron energy distributions with the fluence to dose conversion coefficients (DCC) provided by the International Commission on Radiological Protection (ICRP) is done. The dose estimations are done using the prompt gamma responses (response matrix) obtained for the five distinct gamma peak intensities (boron, hydrogen, carbon and 2 from lead) emitted from the system for incident mono-energetic neutrons ranging from 0.01 eV to 1 GeV. Different workplace neutron spectra are used for the estimation of ambient dose and effective dose to evaluate performances of these three dose estimation methods. The doses (H* (10) and E-AP) estimated using the convolution of the unfolded neutron spectra with the DCC-ICRP result in satisfactory and accurate agreement with the actual dose, followed by the estimated dose obtained from the regression analysis.
引用
收藏
页数:11
相关论文
共 48 条
  • [41] Ecological half-time and effective dose from Chernobyl debris and from nuclear weapons fallout of 137Cs as measured in different Swedish populations
    Rääf, CL
    Hubbard, L
    Falk, R
    Ågren, G
    Vesanen, R
    HEALTH PHYSICS, 2006, 90 (05): : 446 - 458
  • [42] Ambient dose equivalent rates of gamma radiation from natural radionuclides and 137Cs at grasslands and forests in the area of the Belarusian NPP in the pre-commissioning period (2019)
    Ramzaev, Valery
    Bernhardsson, Christian
    Vodovatov, Aleksandr
    Chipiga, Larisa
    Nekrasov, Vladislav
    Dvornik, Alexander
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (05) : 496 - 503
  • [43] Monte Carlo simulations of the secondary neutron ambient and effective dose equivalent rates from surface to suborbital altitudes and low Earth orbit (vol 6, pg 1, 2015)
    El-Jaby, Samy
    LIFE SCIENCES IN SPACE RESEARCH, 2016, 9 : 93 - 96
  • [44] Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose
    DeMarco, J. J.
    Cagnon, C. H.
    Cody, D. D.
    Stevens, D. M.
    McCollough, C. H.
    Zankl, M.
    Angel, E.
    McNitt-Gray, M. F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (09): : 2583 - 2597
  • [45] A COMPARISON OF RESULTS FROM TWO CASE-CROSSOVER METHODS FOR ESTIMATING THE DOSE-RESPONSE RELATIVE RISK OF INJURY DUE TO DRINKING AMONG ER PATIENTS
    Bond, J.
    Ye, Y.
    Cherpitel, C. J.
    ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 2011, 35 (06) : 80A - 80A
  • [46] Attenuation of ambient dose equivalent from neutrons by thick concrete, cast iron and composite shields for high energy proton, 3He, 48Ca and 238U ions on Cu targets for shielding design
    Iwamoto, Yosuke
    Ronningen, R. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (03): : 353 - 363
  • [47] Annual Effective Dose Equivalent and Excess Lifetime Cancer Risk from Measured Indoor Background Ionizing Radiation in Pharmacy, Radiotherapy/Oncology and Radiology Departments of Federal Teaching Hospital, Gombe, Gombe State, Nigeria
    Abdulkareem, Muhammad N.
    Usman, Mudassir M.
    Muhamad, Abdullahi
    Ibrahim, Olanrewaju A.
    Nur, Muhammed S.
    Alhassan, Ahmad
    Nwobodo, Constance C.
    JORDAN JOURNAL OF PHYSICS, 2024, 17 (02): : 253 - 259
  • [48] The Dosimetric Comparison between Measured Tissue Maximum Ratio Directly by Water Phantom and That Calculated from Percentage Depth Dose Measurments in Small Field and Determind the Differnces between Two Methods
    Attalla, Ehab Marouf
    Shoer, Shaimaa
    Elawady, Rasha A.
    Iranian Journal of Medical Physics, 2021, 18 (06) : 384 - 388