Comparison of different methods of estimating the effective dose and the ambient dose equivalent for neutrons from measured prompt gamma intensities

被引:1
|
作者
Udupi, Ashwini [1 ]
Shetty, Pramoda Kumara [1 ]
Panikkath, Priyada [2 ]
Sarkar, Pradip Kumar [3 ]
机构
[1] Manipal Acad Higher Educ, Manipal Inst Technol, Dept Phys, Manipal 576104, Karnataka, India
[2] Alagappa Univ, Dept Phys, Karaikkudi 630004, Tamil Nadu, India
[3] Manipal Acad Higher Educ, Manipal Ctr Nat Sci, Manipal 576104, Karnataka, India
关键词
Neutron dose estimation; Ambient dose equivalent; Effective dose; Prompt gamma; Monte Carlo simulations; POLYETHYLENE;
D O I
10.1016/j.nima.2021.165072
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Estimations of the ambient dose equivalent H*(10) and the effective dose (anterior-posterior) E-AP from prompt gamma intensities are investigated theoretically using Monte Carlo simulations. The system considered consists of a NaI(Tl) gamma detector to measure prompt gamma intensities emitted due to neutron irradiation from a high density polyethylene (HDPE) cylinder embedded in a hollow borated-HDPE cylinder and covered by a layer of lead. A comparative evaluation of different computational techniques of dose estimation, such as, the multiple linear regression method, the detector response-matrix inversion method and the convolution of the unfolded neutron energy distributions with the fluence to dose conversion coefficients (DCC) provided by the International Commission on Radiological Protection (ICRP) is done. The dose estimations are done using the prompt gamma responses (response matrix) obtained for the five distinct gamma peak intensities (boron, hydrogen, carbon and 2 from lead) emitted from the system for incident mono-energetic neutrons ranging from 0.01 eV to 1 GeV. Different workplace neutron spectra are used for the estimation of ambient dose and effective dose to evaluate performances of these three dose estimation methods. The doses (H* (10) and E-AP) estimated using the convolution of the unfolded neutron spectra with the DCC-ICRP result in satisfactory and accurate agreement with the actual dose, followed by the estimated dose obtained from the regression analysis.
引用
收藏
页数:11
相关论文
共 48 条
  • [21] EFFECTIVE INDOOR DOSE OF GAMMA RADIATION FROM BUILDING MATERIALS: COMPARISON OF SEVERAL METHODS FOR ESTIMATION AND POSSIBLE UNDERESTIMATE
    Krmar, M.
    Milic, K.
    Arsenic, I.
    Hansman, J.
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (04) : 452 - 458
  • [22] A COMPARISON OF METHODS FOR ESTIMATING THE WEIGHTED EFFECTIVE DOSE FOR TC-99M-LABELED RADIOPHARMACEUTICALS
    BLECHINGER, JC
    PRINCE, JR
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (09) : 1835 - 1835
  • [23] Calculation of the ambient dose equivalent H*(10) from gamma-ray spectra obtained with scintillation detectors
    Casanovas, Ramon
    Prieto, Elena
    Salvado, Marcal
    APPLIED RADIATION AND ISOTOPES, 2016, 118 : 154 - 159
  • [24] Fast method of determining the ambient dose equivalent at a depth of 10 mm of gamma-neutron fields based on recombination methods
    Kuc, Michal
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (15-16) : 1872 - 1876
  • [25] Comparison of four methods for assessing patient effective dose from radiological examinations
    Theocharopoulos, N
    Perisinakis, K
    Damilakis, J
    Varveris, H
    Gourtsoyiannis, N
    MEDICAL PHYSICS, 2002, 29 (09) : 2070 - 2079
  • [26] Spatial relationship between the field-measured ambient gamma dose equivalent rate and geological conditions in a granitic area, Velence Hills, Hungary: An application of digital spatial analysis methods
    Torres, Silvana Beltran
    Petrik, Attila
    Szabo, Katalin Zsuzsanna
    Jordan, Gyozo
    Yao, Jun
    Szabo, Csaba
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2018, 192 : 267 - 278
  • [27] A comparison of methods for estimating the benchmark dose based on overdispersed data from developmental toxicity studies
    Fung, KY
    Marro, L
    Krewski, D
    RISK ANALYSIS, 1998, 18 (03) : 329 - 342
  • [28] Comparison of different approaches of estimating effective dose from reported exposure data in 3D imaging with interventional fluoroscopy systems
    Svalkvist, Angelica
    Hansson, Jonny
    Bath, Magnus
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [29] Ambient dose equivalent and effective dose from scattered x-ray spectra in mammography for Mo/Mo, Mo/Rh and W/Rh anode/filter combinations
    Kunzel, R
    Herdade, SB
    Costa, PR
    Terini, RA
    Levenhagen, RS
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (08): : 2077 - 2091
  • [30] CALCULATIONAL METHODS FOR ESTIMATING SKIN DOSE FROM ELECTRONS IN CO-60 GAMMA-RAY BEAMS
    HIGGINS, PD
    SIBATA, CH
    ATTIX, FH
    PALIWAL, BR
    MEDICAL PHYSICS, 1983, 10 (05) : 622 - 627