Comparison of different methods of estimating the effective dose and the ambient dose equivalent for neutrons from measured prompt gamma intensities

被引:1
|
作者
Udupi, Ashwini [1 ]
Shetty, Pramoda Kumara [1 ]
Panikkath, Priyada [2 ]
Sarkar, Pradip Kumar [3 ]
机构
[1] Manipal Acad Higher Educ, Manipal Inst Technol, Dept Phys, Manipal 576104, Karnataka, India
[2] Alagappa Univ, Dept Phys, Karaikkudi 630004, Tamil Nadu, India
[3] Manipal Acad Higher Educ, Manipal Ctr Nat Sci, Manipal 576104, Karnataka, India
关键词
Neutron dose estimation; Ambient dose equivalent; Effective dose; Prompt gamma; Monte Carlo simulations; POLYETHYLENE;
D O I
10.1016/j.nima.2021.165072
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Estimations of the ambient dose equivalent H*(10) and the effective dose (anterior-posterior) E-AP from prompt gamma intensities are investigated theoretically using Monte Carlo simulations. The system considered consists of a NaI(Tl) gamma detector to measure prompt gamma intensities emitted due to neutron irradiation from a high density polyethylene (HDPE) cylinder embedded in a hollow borated-HDPE cylinder and covered by a layer of lead. A comparative evaluation of different computational techniques of dose estimation, such as, the multiple linear regression method, the detector response-matrix inversion method and the convolution of the unfolded neutron energy distributions with the fluence to dose conversion coefficients (DCC) provided by the International Commission on Radiological Protection (ICRP) is done. The dose estimations are done using the prompt gamma responses (response matrix) obtained for the five distinct gamma peak intensities (boron, hydrogen, carbon and 2 from lead) emitted from the system for incident mono-energetic neutrons ranging from 0.01 eV to 1 GeV. Different workplace neutron spectra are used for the estimation of ambient dose and effective dose to evaluate performances of these three dose estimation methods. The doses (H* (10) and E-AP) estimated using the convolution of the unfolded neutron spectra with the DCC-ICRP result in satisfactory and accurate agreement with the actual dose, followed by the estimated dose obtained from the regression analysis.
引用
收藏
页数:11
相关论文
共 48 条
  • [1] Estimating the terrestrial gamma dose rate by decomposition of the ambient dose equivalent rate
    Bossew, P.
    Cinelli, G.
    Hernandez-Ceballos, M.
    Cernohlawek, N.
    Gruber, V.
    Dehandschutter, B.
    Menneson, F.
    Bleher, M.
    Stoehlker, U.
    Hellmann, I.
    Weiler, F.
    Tollefsen, T.
    Tognoli, P. V.
    de Cort, M.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2017, 166 : 296 - 308
  • [2] Use of prompt gamma emissions from polyethylene to estimate neutron ambient dose equivalent
    Priyada, P.
    Sarkar, P. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 785 : 135 - 142
  • [3] In-flight measured and predicted ambient dose equivalent and latitude differences on effective dose estimates
    Vergara, JCS
    Gutiérrez, AMR
    Jiménez, RR
    Róman, RDM
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 363 - 370
  • [4] AMBIENT DOSE EQUIVALENTS, EFFECTIVE DOSE EQUIVALENTS, AND EFFECTIVE DOSES FOR NEUTRONS FROM 10 TO 20 MEV
    NABELSSI, BK
    HERTEL, NE
    RADIATION PROTECTION DOSIMETRY, 1993, 48 (02) : 153 - 168
  • [5] COMPARISON OF UNFOLDING METHODS FOR DETERMINING NEUTRON SPECTRUM AND AMBIENT DOSE EQUIVALENT
    Wang, Zhonglu
    Kry, Stephen F.
    Howell, Rebecca M.
    Salehpour, Mohammad
    NUCLEAR TECHNOLOGY, 2009, 168 (03) : 610 - 614
  • [6] Comparison of the neutron ambient dose equivalent and ambient absorbed dose calculations with different GEANT4 physics lists
    Ribeiro, Rosane Moreira
    Souza-Santos, Denison
    RADIATION PHYSICS AND CHEMISTRY, 2017, 139 : 179 - 183
  • [7] Comparison of different methods for the assessment of the environmental gamma dose
    Losana, MC
    Magnoni, M
    Righino, F
    RADIATION PROTECTION DOSIMETRY, 2001, 97 (04) : 333 - 336
  • [8] A COMPARISON OF 2 METHODS FOR ESTIMATING EFFECTIVE DOSE IN ABDOMINAL RADIOLOGY
    MARSHALL, NW
    FAULKNER, K
    BUSCH, HP
    MARSH, DM
    PFENNING, H
    RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 367 - 369
  • [9] AMBIENT DOSE-EQUIVALENT, DEEP DOSE-EQUIVALENT INDEX, AND ICRU SPHERE DEPTH-DOSE CALCULATIONS FOR NEUTRONS FROM 30 TO 180 MEV
    NABELSSI, BK
    HERTEL, NE
    RADIATION PROTECTION DOSIMETRY, 1994, 51 (03) : 169 - 182