Flashover performance of ERV station post insulators covered with ice

被引:0
|
作者
Farzaneh, M [1 ]
Farzaneh-Dehkordi, J [1 ]
Zhang, J [1 ]
机构
[1] Univ Quebec Chicoutimi, NSERC Hydro Quebec, Ind Chair Atmospher Icing Power Network Equipment, Chicoutimi, PQ G1V 2M3, Canada
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The icing performance of standard- shed-design porcelain insulators, with a dry arcing distance of up to 4.17 in, corresponding to full-scale Hydro-Quebec 735 kV substation insulators, was investigated. Artificial ice was formed at -12degreesC in a climate room from supercooled water droplets produced by a set of pneumatic nozzles. The relationship between the maximum withstand voltage, Vws, and insulator length was determined. With an applied water conductivity of 30 muS/cm and an ice thickness of 15 mm, measured on a rotating monitoring cylinder, flashover may occur at service voltage. Moreover, the Vws of the ice-covered insulators tested increases non-linearly with an increase in insulator length. These results are of great importance for the design of EHV substation insulators used in cold climate regions.
引用
收藏
页码:37 / 40
页数:4
相关论文
共 50 条
  • [41] Flashover performance of IEEE standard insulators under ice conditions
    Farzaneh, M
    Kiernicki, J
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (04) : 1602 - 1613
  • [42] Flashover performance of ieee standard insulators under ice conditions
    Farzaneh, M
    Kiernicki, J
    1996 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE PROCEEDINGS, 1996, : 143 - 151
  • [43] Nonlinear Characteristics of Leakage Current for Flashover Monitoring of Ice-covered Suspension Insulators
    Liu, Yong
    Farzaneh, Masoud
    Du, B. X.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (03) : 1242 - 1250
  • [44] DC Flashover Performance and Effect of Sheds Configuration on Polluted and Ice-covered Composite Insulators at Low Atmospheric Pressure
    Jiang, Xingliang
    Chao, Yafeng
    Zhang, Zhijin
    Hu, Jianlin
    Shu, Lichun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (01) : 97 - 105
  • [45] Calculation of Critical Flashover Voltage of Ice-Covered Insulators Using the Finite Element Method
    Volat, C.
    Farzaneh, M.
    Mhaguen, N.
    CEIDP: 2009 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2009, : 403 - 406
  • [46] Equivalence of Influence of Pollution Simulating Methods on DC Flashover Stress of Ice-Covered Insulators
    Jiang, Xingliang
    Chen, Ling
    Zhang, Zhijin
    Sun, Caixin
    Hu, Jianlin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) : 2113 - 2120
  • [47] Experimental study and mathematical modelling of flashover on extra-high voltage insulators covered with ice
    Farzaneh-Dehkordi, J
    Zhang, J
    Farzaneh, M
    HYDROLOGICAL PROCESSES, 2004, 18 (18) : 3471 - 3480
  • [48] Influence of wind velocity on ice accretion and flashover performance of composite insulators
    Shu, Lichun
    Wang, Shijing
    Ye, Kaiyan
    Deng, Shasha
    Jiang, Xingliang
    Hu, Qin
    He, Yanzhun
    Liang, Jian
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (06): : 1533 - 1540
  • [49] DC pollution flashover and rain flashover performance for composite post insulators at high altitudes
    Zhao, Feng
    Zhang, Fuzeng
    Yang, Haolin
    Guan, Zhicheng
    Wang, Liming
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2009, 49 (10): : 1581 - 1584
  • [50] Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1000 WUHV AC transmission lines
    Hu, Jianlin
    Sun, Caixin
    Jiang, Xingliang
    Zhang, Zhijin
    Shu, Lichun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) : 1347 - 1356