Flashover performance of ERV station post insulators covered with ice

被引:0
|
作者
Farzaneh, M [1 ]
Farzaneh-Dehkordi, J [1 ]
Zhang, J [1 ]
机构
[1] Univ Quebec Chicoutimi, NSERC Hydro Quebec, Ind Chair Atmospher Icing Power Network Equipment, Chicoutimi, PQ G1V 2M3, Canada
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The icing performance of standard- shed-design porcelain insulators, with a dry arcing distance of up to 4.17 in, corresponding to full-scale Hydro-Quebec 735 kV substation insulators, was investigated. Artificial ice was formed at -12degreesC in a climate room from supercooled water droplets produced by a set of pneumatic nozzles. The relationship between the maximum withstand voltage, Vws, and insulator length was determined. With an applied water conductivity of 30 muS/cm and an ice thickness of 15 mm, measured on a rotating monitoring cylinder, flashover may occur at service voltage. Moreover, the Vws of the ice-covered insulators tested increases non-linearly with an increase in insulator length. These results are of great importance for the design of EHV substation insulators used in cold climate regions.
引用
收藏
页码:37 / 40
页数:4
相关论文
共 50 条
  • [31] DC flashover of artificial ice-covered insulators at low atmospheric pressure
    Farzaneh, M
    Li, Y
    Fikke, SM
    Mercure, H
    PROCEEDINGS OF THE NINTH (1999) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL II, 1999, 1999, : 612 - 615
  • [32] Application of Identification Methods for Predicting the Flashover Voltage of Contaminated Insulators Covered with Ice
    Sabri, Y.
    Farzaneh, M.
    Zhang, J.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (02) : 451 - 457
  • [33] Flashover Characteristics of 110 kV Snow-covered Post Insulators
    Mei H.
    Shi Q.
    Lu M.
    Wang L.
    Liu Z.
    Zhang C.
    Gaodianya Jishu/High Voltage Engineering, 2018, 44 (12): : 3944 - 3950
  • [34] DC flashover of artificial ice-covered insulators at low atmospheric pressure
    Farzaneh, M.
    Li, Y.
    Fikke, S.M.
    Mercure, H.
    Proceedings of the International Offshore and Polar Engineering Conference, 1999, 2 : 612 - 615
  • [35] PERFORMANCE OF INSULATORS COVERED WITH SNOW OR ICE.
    Fujimura, Tetsuo
    Naito, Katsuhiko
    Hasegawa, Yoshio
    Kawaguchi, Toshiyuki
    1979,
  • [36] Influences of Grading Ring Arrangement on AC Flashover Performance of 220 kV Ice-covered Composite Insulators
    Shu, Lichun
    Wang, Shijing
    Jiang, Xingliang
    Hu, Qin
    He, Yanzhun
    Wu, Zhi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (06) : 2652 - 2661
  • [37] Restoration of the insulation of ice-covered post insulators
    Lanoie, Robert
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2011, 65 (01) : 39 - 42
  • [38] Effects of Shed Configuration on AC Flashover Performance of Ice-covered Composite Long-rod Insulators
    Hu, Qin
    Shu, Lichun
    Jiang, Xingliang
    Sun, Caixin
    Zhang, Zhijin
    Hu, Jianlin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (01) : 200 - 208
  • [39] Monitoring Leakage Current of Ice-covered Station Post Insulators using Artificial Neural Networks
    Volat, C.
    Meghnefi, F.
    Farzaneh, M.
    Ezzaidi, H.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (02) : 443 - 450
  • [40] Modeling of AC Flashover on Ice-covered Composite Insulators with Different Shed Configurations
    Shu, Lichun
    Wang, Shijing
    Jiang, Xingliang
    Hu, Qin
    Liang, Jian
    Yin, Pancheng
    Chen, Ji
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (06) : 2642 - 2651