Assessment of the carotid artery by MRI at 3T: A study on reproducibility

被引:47
|
作者
Dehnavi, Reza Alizadeh
Doornbos, Joost
Tamsma, Jouke T.
Stuber, Matthias
Putter, Hein
van der Geest, Rob J.
Lamb, Hildo J.
de Roos, Albert
机构
[1] Leiden Univ, Med Ctr, Dept Gen Internal Med & Endocrinol, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
[3] Johns Hopkins Univ, Sch Med, Dept Radiol, Div MRI Res, Baltimore, MD 21205 USA
[4] Leiden Univ, Med Ctr, Dept Med Stat & Bioinformat, NL-2300 RC Leiden, Netherlands
关键词
carotid artery; vessel wall area; luminal area; 3T MRI; reproducibility; fast gradient echo;
D O I
10.1002/jmri.20904
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine the reproducibility of carotid artery dimension measurement using 3T MRI. Materials and Methods: Ten healthy volunteers underwent three scans on two occasions for assessment of total vessel wall area (TVWA), total luminal area (TLA), and minimum (MinT) and maximum (MaxT) vessel wall thickness. A double inversion-recovery (IR) fast gradient-echo (FGRE) sequence was used on a commercial 3T system. During the first visit the subjects were scanned twice. The third scan was performed at least four days later. One observer traced all scans, and a second observer retraced the first scan series. Results: For TVWA an interclass correlation (ICC) of 0.994 was calculated with all three scans taken into account. The interobserver ICC was 0.984. The agreement between the scans for TLA showed an ICC of 0.982 with an interobserver ICC of 0.998. For MinT and MaxT an ICC of 0.843 and 0.935 were calculated, with interobserver ICCs of 0.860 and 0.726, respectively. Conclusion: With the use of a commercial 3T MR system. TVWA, TLA, and wall thickness meaurements of the carotid artery can be assessed with good reproducibility.
引用
收藏
页码:1035 / 1043
页数:9
相关论文
共 50 条
  • [31] Novel use of 3T MRI in assessment of optic nerve volume in glaucoma
    Norlina M. Ramli
    Sabrilhakim Sidek
    Fadzlina A. Rahman
    Mohammadreza Peyman
    Mimiwati Zahari
    Kartini Rahmat
    Norlisah Ramli
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 995 - 1000
  • [32] Vessel Wall Analysis Using 3T MRI in Cerebral Main Artery Stenosis
    Igase, K.
    Matsubara, I.
    Igase, M.
    Arai, M.
    Goishi, J.
    Sadamoto, K.
    CEREBROVASCULAR DISEASES, 2014, 37 : 201 - 201
  • [33] Vessel wall analysis of disecting aneurysm of vertebral artery using 3T MRI
    Igase, K.
    Tei, N.
    Matsubara, I.
    Ohnishi, T.
    Sadamoto, K.
    CEREBROVASCULAR DISEASES, 2017, 43
  • [34] Reproducibility and accuracy of semiautomatic assessment of carotid artery stenosis on CTA
    Borst, J.
    Marquering, H. A.
    Kappelhof, M.
    Zadi, T.
    van Dijk, A.
    Nederkoorn, P. J.
    van den Berg, R.
    van der Lugt, A.
    Majoie, C. B. L. M.
    INTERNATIONAL JOURNAL OF STROKE, 2014, 9 : 127 - 127
  • [35] Cortical Cerebral Microinfarcts on 3T Magnetic Resonance Imaging in Patients With Carotid Artery Stenosis
    Takasugi, Junji
    Miwa, Kaori
    Watanabe, Yoshiyuki
    Okazaki, Shuhei
    Todo, Kenichi
    Sasaki, Tsutomu
    Sakaguchi, Manabu
    Mochizuki, Hideki
    STROKE, 2019, 50 (03) : 639 - 644
  • [36] An 8-channel Phased Array for Carotid Artery Magnetic Resonance Imaging at 3T
    Luo, Chao
    Hu, Xiaoqing
    Chen, Xiao
    Zhang, Lei
    Liu, Shengping
    Liu, Xin
    Zheng, Hairong
    Li, Ye
    2015 ASIA-PACIFIC MICROWAVE CONFERENCE (APMC), VOLS 1-3, 2015,
  • [37] PHANTOM STUDY OF MRI AT 3T FOR SPINE INSTRUMENTATION WITH METAL SUPPRESSION
    Middleton, Devon M.
    Harrop, James
    Flanders, Adam
    Faro, Scott
    Talekar, Kiran
    Krisa, Laura
    Mohamed, Feroze B.
    JOURNAL OF NEUROTRAUMA, 2018, 35 (16) : A169 - A169
  • [38] A 3T BOLD functional MRI study of the neural underpinnings of depression
    Bernasconi, A.
    Benedetti, F.
    Blasi, V.
    Cadioli, M.
    Colombo, C.
    Dallaspezia, S.
    Falini, A.
    Radaelli, D.
    Scotti, G.
    EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2006, 16 : S273 - S274
  • [39] Non-invasive assessment of HVPG with quantitative MRI measures of liver T1 and superior mesenteric artery velocity at 3T
    Scott, Robert
    Bradley, Christopher R.
    Cox, Eleanor F.
    Palaniyappan, Naaventhan
    Ramjas, Gregory
    Thurley, Peter
    Guha, Neil
    Francis, Susan
    Aithal, Guruprasad
    JOURNAL OF HEPATOLOGY, 2019, 70 (01) : E679 - E679
  • [40] Scan-rescan reproducibility of quantitative assessment of inflammatory carotid atherosclerotic plaque using dynamic contrast-enhanced 3T CMR in a multi-center study
    Chen, Huijun
    Sun, Jie
    Kerwin, William S.
    Balu, Niranjan
    Neradilek, Moni B.
    Hippe, Daniel S.
    Isquith, Daniel
    Xue, Yunjing
    Yamada, Kiyofumi
    Peck, Suzanne
    Yuan, Chun
    O'Brien, Kevin D.
    Zhao, Xue-Qiao
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16