Assessment of the carotid artery by MRI at 3T: A study on reproducibility

被引:47
|
作者
Dehnavi, Reza Alizadeh
Doornbos, Joost
Tamsma, Jouke T.
Stuber, Matthias
Putter, Hein
van der Geest, Rob J.
Lamb, Hildo J.
de Roos, Albert
机构
[1] Leiden Univ, Med Ctr, Dept Gen Internal Med & Endocrinol, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
[3] Johns Hopkins Univ, Sch Med, Dept Radiol, Div MRI Res, Baltimore, MD 21205 USA
[4] Leiden Univ, Med Ctr, Dept Med Stat & Bioinformat, NL-2300 RC Leiden, Netherlands
关键词
carotid artery; vessel wall area; luminal area; 3T MRI; reproducibility; fast gradient echo;
D O I
10.1002/jmri.20904
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine the reproducibility of carotid artery dimension measurement using 3T MRI. Materials and Methods: Ten healthy volunteers underwent three scans on two occasions for assessment of total vessel wall area (TVWA), total luminal area (TLA), and minimum (MinT) and maximum (MaxT) vessel wall thickness. A double inversion-recovery (IR) fast gradient-echo (FGRE) sequence was used on a commercial 3T system. During the first visit the subjects were scanned twice. The third scan was performed at least four days later. One observer traced all scans, and a second observer retraced the first scan series. Results: For TVWA an interclass correlation (ICC) of 0.994 was calculated with all three scans taken into account. The interobserver ICC was 0.984. The agreement between the scans for TLA showed an ICC of 0.982 with an interobserver ICC of 0.998. For MinT and MaxT an ICC of 0.843 and 0.935 were calculated, with interobserver ICCs of 0.860 and 0.726, respectively. Conclusion: With the use of a commercial 3T MR system. TVWA, TLA, and wall thickness meaurements of the carotid artery can be assessed with good reproducibility.
引用
收藏
页码:1035 / 1043
页数:9
相关论文
共 50 条
  • [21] 1H-MRS for the assessment of renal triglyceride content in humans at 3T: A primer and reproducibility study
    Dekkers, Ilona A.
    de Heer, Paul
    Bizino, Maurice B.
    de Vries, Aiko P. J.
    Lamb, Hildo J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (02) : 507 - 513
  • [22] Neuromelanin in Parkinson's disease: A 3T MRI study
    Pietracupa, S.
    Martin-Bastida, A.
    Kaim, N. L.
    Schwarz, S.
    Auer, D.
    Berardelli, A.
    Piccini, P.
    MOVEMENT DISORDERS, 2016, 31 : S402 - S402
  • [23] Local excitation black blood imaging at 3T: Application to the carotid artery wall
    Bornstedt, Axel
    Bernhardt, Peter
    Hombach, Vinzenz
    Kamenz, Joachim
    Spiess, Jochen
    Subgang, Anne
    Rasche, Volker
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) : 1207 - 1211
  • [24] Quantitative Susceptibility Mapping of Human Brain at 3T: A Multisite Reproducibility Study
    Lin, P-Y
    Chao, T-C.
    Wu, M-L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (03) : 467 - 474
  • [25] The value of high-field MRI (3T) in the assessment of sellar lesions
    Pinker, K
    Ba-Ssalamah, A
    Wolfsberger, S
    Mlynarik, V
    Knosp, E
    Trattnig, S
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 54 (03) : 327 - 334
  • [26] Assessment of adipose tissue from whole body 3T MRI scans
    Song, Ting
    An, Jing
    Chen, Qun
    Lee, Vivian
    Laine, Andrew
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 7012 - 7015
  • [27] 3D Blood Flow Characteristics in the Carotid Artery Bifurcation Assessed by Flow-Sensitive 4D MRI at 3T
    Harloff, A.
    Albrecht, F.
    Spreer, J.
    Stalder, A. F.
    Bock, J.
    Frydrychowicz, A.
    Schoellhorn, J.
    Hetzel, A.
    Schumacher, M.
    Hennig, J.
    Markl, M.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) : 65 - 74
  • [28] MRI of the left atrium at 3T: evaluation of measurement reproducibility in healthy volunteers and patients with cardiovascular disease
    Gandy, Stephen J.
    Matthew, Shona
    Rekhraj, Sushma
    Szwejkowski, Benjamin
    Crowe, Elena
    Struthers, Allan D.
    Houston, J. Graeme
    ACTA RADIOLOGICA, 2016, 57 (12) : 1468 - 1475
  • [29] Novel use of 3T MRI in assessment of optic nerve volume in glaucoma
    Ramli, Norlina M.
    Sidek, Sabrilhakim
    Rahman, Fadzlina A.
    Peyman, Mohammadreza
    Zahari, Mimiwati
    Rahmat, Kartini
    Ramli, Norlisah
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (06) : 995 - 1000
  • [30] 10-channel phased-array coil for carotid wall MRI at 3T
    de Buck, Matthijs H. S.
    Jezzard, Peter
    Frost, Robert
    Randell, Chris
    Hurst, Katherine
    Choudhury, Robin P.
    Robson, Matthew D.
    Biasiolli, Luca
    PLOS ONE, 2023, 18 (08):