Assessment of the carotid artery by MRI at 3T: A study on reproducibility

被引:47
|
作者
Dehnavi, Reza Alizadeh
Doornbos, Joost
Tamsma, Jouke T.
Stuber, Matthias
Putter, Hein
van der Geest, Rob J.
Lamb, Hildo J.
de Roos, Albert
机构
[1] Leiden Univ, Med Ctr, Dept Gen Internal Med & Endocrinol, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
[3] Johns Hopkins Univ, Sch Med, Dept Radiol, Div MRI Res, Baltimore, MD 21205 USA
[4] Leiden Univ, Med Ctr, Dept Med Stat & Bioinformat, NL-2300 RC Leiden, Netherlands
关键词
carotid artery; vessel wall area; luminal area; 3T MRI; reproducibility; fast gradient echo;
D O I
10.1002/jmri.20904
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine the reproducibility of carotid artery dimension measurement using 3T MRI. Materials and Methods: Ten healthy volunteers underwent three scans on two occasions for assessment of total vessel wall area (TVWA), total luminal area (TLA), and minimum (MinT) and maximum (MaxT) vessel wall thickness. A double inversion-recovery (IR) fast gradient-echo (FGRE) sequence was used on a commercial 3T system. During the first visit the subjects were scanned twice. The third scan was performed at least four days later. One observer traced all scans, and a second observer retraced the first scan series. Results: For TVWA an interclass correlation (ICC) of 0.994 was calculated with all three scans taken into account. The interobserver ICC was 0.984. The agreement between the scans for TLA showed an ICC of 0.982 with an interobserver ICC of 0.998. For MinT and MaxT an ICC of 0.843 and 0.935 were calculated, with interobserver ICCs of 0.860 and 0.726, respectively. Conclusion: With the use of a commercial 3T MR system. TVWA, TLA, and wall thickness meaurements of the carotid artery can be assessed with good reproducibility.
引用
收藏
页码:1035 / 1043
页数:9
相关论文
共 50 条
  • [1] Assessment of the unstable carotid plaque using 3T MRI
    Skagen, K.
    Skjelland, M.
    Scott, H.
    Hol, P. K.
    Russell, D.
    CEREBROVASCULAR DISEASES, 2013, 35 : 48 - 48
  • [2] Cortical Microinfarcts on 3T MRI in Patients With Carotid Artery Stenosis.
    Takasugi, Junji
    Miwa, Kaori
    Watanabe, Yoshiyuki
    Okazaki, Shuhei
    Todo, Kenichi
    Sasaki, Tsutomu
    Mochizuki, Hideki
    STROKE, 2019, 50
  • [3] Fast Measurement of Blood T1 in the Human Carotid Artery at 3T: Accuracy, Precision, and Reproducibility
    Li, Wenbo
    Liu, Peiying
    Lu, Hanzhang
    Strouse, John J.
    Zijl, Peter C. M. van
    Qin, Qin
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (06) : 2296 - 2302
  • [4] Sex Differences of Carotid Atherosclerotic Plaque: In vivo 3T MRI Study
    Ota, Hideki
    Reeves, Mathew J.
    Zhu, David C.
    Yuan, Chun
    DeMarco, J. K.
    CIRCULATION, 2009, 120 (18) : S1037 - S1037
  • [5] Increasing spatial resolution of 3T MRI scanning improves reproducibility of carotid arterial wall dimension measurements
    van Wijk, Diederik F.
    Strang, Aart C.
    Duivenvoorden, Raphael
    Enklaar, Dirk-Jan F.
    van der Geest, Rob J.
    Kastelein, John J. P.
    de Groot, Eric
    Stroes, Erik S. G.
    Nederveen, Aart J.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (03) : 219 - 226
  • [6] Increasing the Spatial Resolution of 3T Carotid MRI Has No Beneficial Effect for Plaque Component Measurement Reproducibility
    van Wijk, Diederik F.
    Strang, Aart C.
    Duivenvoorden, Raphael
    Enklaar, Dirk-Jan F.
    Zwinderman, Aeilko H.
    van der Geest, Rob J.
    Kastelein, John J. P.
    de Groot, Eric
    Stroes, Erik S. G.
    Nederveen, Aart J.
    PLOS ONE, 2015, 10 (07):
  • [7] Increasing spatial resolution of 3T MRI scanning improves reproducibility of carotid arterial wall dimension measurements
    Diederik F. van Wijk
    Aart C. Strang
    Raphael Duivenvoorden
    Dirk-Jan F. Enklaar
    Rob J. van der Geest
    John J. P. Kastelein
    Eric de Groot
    Erik S. G. Stroes
    Aart J. Nederveen
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 219 - 226
  • [8] Carotid MRI Detection of Intraplaque Hemorrhage at 3T and 1.5T
    McNally, J. Scott
    Yoon, Hyo-Chun
    Kim, Seong-Eun
    Narra, Krishna K.
    McLaughlin, Michael S.
    Parker, Dennis L.
    Treiman, Gerald S.
    JOURNAL OF NEUROIMAGING, 2015, 25 (03) : 390 - 396
  • [9] Scan-Rescan Reproducibility of Carotid Atherosclerotic Plaque Morphology and Tissue Composition Measurements Using Multicontrast MRI at 3T
    Li, Feiyu
    Yarnykh, Vasily L.
    Hatsukami, Thomas S.
    Chu, Baocheng
    Balu, Niranjan
    Wang, Jinnan
    Underhill, Hunter R.
    Zhao, Xihai
    Smith, Robin
    Yuan, Chun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) : 168 - 176
  • [10] Atherosclerotic Carotid Plaque Composition: A 3T and 7T MRI-Histology Correlation Study
    Gonzalez, M. R. Lopez
    Foo, S. Y.
    Holmes, W. M.
    Stewart, W.
    Muir, K. W.
    Condon, B.
    Welch, G.
    Forbes, K. P.
    JOURNAL OF NEUROIMAGING, 2016, 26 (04) : 406 - 413