A spectroscopic Monte-Carlo model to simulate the response of pixelated CdTe based detectors

被引:10
|
作者
Koch-Mehrin, K. A. L. [1 ]
Lees, J. E. [1 ]
Bugby, S. L. [1 ,2 ]
机构
[1] Univ Leicester, Dept Phys & Astron, Space Res Ctr, Leicester LE1 7RH, Leics, England
[2] Univ Loughborough, Dept Phys, Ctr Sensing & Imaging Sci, Loughborough LE11 3TU, Leics, England
关键词
Monte Carlo detector model; CdTe; HEXITEC; Charge sharing; Pixelated compound semiconductor detectors; CHARGE; SCATTERING; RADIATION;
D O I
10.1016/j.nima.2020.164241
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fully spectroscopic Monte Carlo model has been developed to predict the spectroscopic performance of pixelated CdTe based detectors. The model incorporates photon attenuation by the photoelectric effect, Compton scattering and Rayleigh scattering. Charge transport equations are used to simulate the size of the electron cloud, approximated by a symmetrical two-dimensional Gaussian distribution, as it drifts to be read out at the detector anode. Direct comparisons are made between simulated data and experimentally acquired spectra from a 1 mm thick CdTe sensor coupled to the HEXITEC detector ASIC. The probability of an absorbed photon leading to charge sharing across pixels as a function of incoming photon energy is investigated. The charge cloud size was found to be dominated by cloud growth during drift for photon energies <100 keV. Furthermore, the portion of charge sharing events due to fluorescence from within the CdTe sensor is calculated-these events are distinguished from regular charge sharing events since their energy response differs. The model described is shown to give a good estimate of the total probability of charge sharing for energies up to 140 keV. CdTe sensor thickness, bias voltage, pixel size and electronic noise threshold can be adjusted to model a range of detector architectures.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] MONTE-CARLO SIMULATION OF THE CUBIC MODEL
    SABLIK, MJ
    COOK, M
    VUONG, N
    PHANI, L
    ZAWONSKI, M
    PHANI, M
    JOURNAL OF APPLIED PHYSICS, 1979, 50 (11) : 7385 - 7387
  • [22] MONTE-CARLO MODEL OF PLASMA AFTERGLOW
    BLECHA, J
    VEIS, S
    ACTA PHYSICA SLOVACA, 1981, 31 (06) : 329 - 339
  • [23] Uniform Monte-Carlo Model Checking
    Oudinet, Johan
    Denise, Alain
    Gaudel, Marie-Claude
    Lassaigne, Richard
    Peyronnet, Sylvain
    FUNDAMENTAL APPROACHES TO SOFTWARE ENGINEERING, 2011, 6603 : 127 - +
  • [24] MONTE-CARLO MODEL OF TRACKING BEHAVIOR
    ADAMS, JA
    WEBBER, CE
    HUMAN FACTORS, 1963, 5 (01) : 81 - 102
  • [25] A MONTE-CARLO STUDY OF THE BNNNI MODEL
    AYDIN, M
    YALABIK, MC
    JOURNAL OF PHYSICS A-MATHEMATICAL AND GENERAL, 1989, 22 (18): : 3981 - 3989
  • [26] A MONTE-CARLO STUDY OF THE XY MODEL
    FUCITO, F
    PHYSICS LETTERS A, 1983, 94 (02) : 99 - 102
  • [27] Monte-Carlo Spray Cooling Model
    Kreitzer, Paul J.
    Kuhlman, John M.
    SPACE, PROPULSION & ENERGY SCIENCES INTERNATIONAL FORUM SPESIF- 2010, 2010, 1208 : 84 - 98
  • [28] Evaluation of Compton gamma camera prototype based on pixelated CdTe detectors
    Calderon, Y.
    Chmeissani, M.
    Kolstein, M.
    De Lorenzo, G.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [29] MONTE-CARLO SOLUTIONS OF THE SOLID ANGLE INTEGRALS FOR RADIATION DETECTORS
    STAVROULAKI, BT
    KAPLANIS, SN
    COMPUTER PHYSICS COMMUNICATIONS, 1979, 18 (01) : 7 - 12
  • [30] MONTE-CARLO SIMULATIONS OF INTERNAL PHOTOEMISSION IN SILICIDE INFRARED DETECTORS
    EGAN, JM
    INFRARED PHYSICS, 1991, 31 (04): : 395 - 400