A proposed Compton camera prototype based on pixelated CdTe is simulated and evaluated in order to establish its feasibility and expected performance in real laboratory tests. The system is based on module units containing a 2 x 4 array of square CdTe detectors of 10 x 10 mm(2) area and 2 mm thickness. The detectors are pixelated and stacked forming a 3D detector with voxel sizes of 2 x 1 x 2 mm(3). The camera performance is simulated with Geant4-based Architecture for Medicine-Oriented Simulations(GAMOS) and the Origin Ensemble(OE) algorithm is used for the image reconstruction. The simulation shows that the camera can operate with up to 10(4) Bq source activities with equal efficiency and is completely saturated at 10(9) Bq. The efficiency of the system is evaluated using a simulated F-18 point source phantom in the center of the Field-of-View (FOV) achieving an intrinsic efficiency of 0.4 counts per second per kilobecquerel. The spatial resolution measured from the point spread function (PSF) shows a FWHM of 1.5 mm along the direction perpendicular to the scatterer, making it possible to distinguish two points at 3 mm separation with a peak-to-valley ratio of 8.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Prototype of Compton Camera using high resolution Si/CdTe detectors - Si/CdTe Compton camera as a polarimeter
    Mitani, T
    Tanaka, T
    Nakazawa, K
    Takahashi, T
    Takashima, T
    Tajima, H
    Nakamura, H
    Nomachi, M
    Nakamoto, T
    Fukazawa, Y
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3588 - 3592
  • [2] Characterization of a module with pixelated CdTe detectors for possible PET, PEM and compton camera applications
    Arino-Estrada, G.
    Chmeissani, M.
    de Lorenzo, G.
    Puigdengoles, C.
    Martinez, R.
    Cabruja, E.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [3] A gamma camera based on CdTe detectors
    Eisen, Y
    Shor, A
    Gilath, C
    Tsabarim, M
    Chouraqui, P
    Hellman, C
    Lubin, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 474 - 478
  • [4] A prototype Si/CdTe Compton camera and the polarization measurement
    Mitani, T
    Tanaka, T
    Nakazawa, K
    Takahashi, T
    Takashima, T
    Tajima, H
    Nakamura, H
    Nomachi, M
    Nakamoto, T
    Fukazawa, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2432 - 2437
  • [5] Development of semiconductor imaging detectors for a Si/CdTe Compton camera
    Watanabe, Shin
    Takeda, Shin'ichiro
    Ishikawa, Shin-nosuke
    Odaka, Hirokazu
    Ushio, Masayoshi
    Tanaka, Takaaki
    Nakazawa, Kazuhiro
    Takahashi, Tadayuki
    Tajima, Hiroyasu
    Fukazawa, Yasushi
    Kuroda, Yoshikatsu
    Onishi, Mitsunobu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02): : 871 - 877
  • [6] A Compton camera prototype for prompt gamma medical imaging
    Thirolf, P. G.
    Aldawood, S.
    Boehmer, M.
    Bortfeldt, J.
    Castelhano, I.
    Dedes, G.
    Fiedler, F.
    Gernhaeuser, R.
    Golnik, C.
    Helmbrecht, S.
    Hueso-Gonzalez, F.
    Kolff, H. V. D.
    Kormoll, T.
    Lang, C.
    Liprandi, S.
    Lutter, R.
    Marinsek, T.
    Maier, L.
    Pausch, G.
    Petzoldt, J.
    Roemer, K.
    Schaart, D.
    Parodi, K.
    12TH INTERNATIONAL CONFERENCE ON NUCLEUS-NUCLEUS COLLISIONS 2015, 2016, 117
  • [7] Collimator designed for a pixellated gamma camera based on semiconductor CdTe detectors
    Chambron, J
    Dumitresco, B
    Mauss, Y
    Yu, O
    Matz, R
    Jahnke, A
    Siffert, P
    MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 66 - 79
  • [8] Modeling, Simulation, and Evaluation of a Compton Camera Based on a Pixelated Solid-State Detector
    Calderon, Yonatan
    Kolstein, Machiel
    Uzun, Dilber
    De Lorenzo, Gianluca
    Chmeissani, Mokhtar
    Arce, Pedro
    Arino, Gerard
    Cabruja, Enric
    Canadas, Mario
    Gabriel Macias-Montero, Jose
    Martinez, Ricardo
    Mikhaylova, Ekaterina
    Ozsahin, Ilker
    Puigdengoles, Carles
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2708 - 2715
  • [9] PROTOTYPE DESIGN OF MULTIPLE COMPTON GAMMA-RAY CAMERA
    KAMAE, T
    HANADA, N
    ENOMOTO, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 352 - 355
  • [10] Development of a small field of view gamma camera using a pixelated CdTe detector
    Ishitsu, T.
    Takahashi, I.
    Tsuchiya, K.
    Kawaguchi, T.
    Yamada, N.
    Amemiya, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S146 - S146