Monte Carlo simulation of response function for a NaI(T1) detector for gamma rays from 241Am/Be source

被引:22
|
作者
Vitorelli, JC
Silva, AX
Crispim, VR
da Fonseca, ES
Pereira, WW
机构
[1] Univ Fed Rio de Janeiro, COPPE, DNC, PEN,EEJCT, BR-21945970 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Rio de Janeiro, COPPE, DNC, PEN,EEJCT, BR-68509 Rio De Janeiro, RJ, Brazil
[3] Inst Radioprot & Dosimetria, BR-22642970 Rio De Janeiro, RJ, Brazil
关键词
response function; NaI(T1) detector; Am-241/Be neutron source; Monte Carlo simulation;
D O I
10.1016/j.apradiso.2004.07.010
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The general purpose computer code MCNP4B was used to simulate the response function of a bare NaI(T1) detector crystal for gamma rays from an Am-241/Be source capsule. The simulated spectral shape generated by the MCNP4B code was compared with the measured spectral shape obtained using a gamma-ray spectrometer with a cylindrical shape, 7.62 cm x 7.62 cm, NaI(T1). In general, the agreement between the simulation and the experimental response function was good. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:619 / 622
页数:4
相关论文
共 50 条
  • [21] Validation of gamma scanning method for optimizing NaI(Tl) detector model in Monte Carlo simulation
    Huynh Dinh Chuong
    Nguyen Quoc Hung
    Nguyen Thi My Le
    Vo Hoang Nguyen
    Tran Thien Thanh
    APPLIED RADIATION AND ISOTOPES, 2019, 149 : 1 - 8
  • [22] Monte Carlo simulation of the NaI(Tl) detector response to measure gold activated foils
    Amgarou, K.
    Domingo, C.
    Bouassoule, T.
    Fernandez, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (17): : 2944 - 2951
  • [23] MONTE CARLO SIMULATION STUDY ON THE 241Am-Be RADIONUCLIDE SOURCE REFERENCE NEUTRON RADIATION
    Liu, Yixin
    Zhang, Song
    Qian, Yikun
    Huang, Yuchen
    Mao, Benjiang
    Feng, Peng
    Chen, Zhiqiang
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2020, 35 (04): : 283 - 293
  • [24] Monte Carlo study of a flexible device for in situ PGNAA using 241Am–Be source: application to total chlorine determination
    R. Khelifi
    P. Bode
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 309 : 189 - 193
  • [25] Experimental validation of response function of a NaI (Tl) detector modeled with Monte Carlo codes
    Hajheidari, M. T.
    Safari, M. J.
    Afarideh, H.
    Rouhi, H.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [26] A Monte Carlo simulation and deconvolution study of detector response function
    Feng, Y.
    Lamba, M.
    Elson, H.
    Kassing, W.
    Spitz, H.
    MEDICAL PHYSICS, 2007, 34 (06) : 2406 - 2406
  • [27] FLUORESCENT RESPONSE OF NAI(T1) CSI(T1) CSI(NA) AND CAF2(EU) TO X-RAYS AND LOW ENERGY GAMMA RAYS
    AITKEN, DW
    BERON, BL
    YENICAY, G
    ZULLIGER, HR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1967, NS14 (01) : 468 - +
  • [28] Development of a computer code using the EGS4 Monte Carlo simulation system to evaluate the response of a NaI(T1) detector to photons with energies below 300 keV
    Al-Ghorabie, FHH
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (01) : 85 - 92
  • [29] Monte carlo simulation of in situ gamma-spectra recorded by NaI (Tl) detector in the marine environment
    Yiming Wang
    Yingying Zhang
    Ning Wu
    Bingwei Wu
    Yan Liu
    Xuan Cao
    Qian Wang
    Journal of Ocean University of China, 2015, 14 : 471 - 474
  • [30] Monte carlo simulation of in situ gamma-spectra recorded by NaI (Tl) detector in the marine environment
    Wang Yiming
    Zhang Yingying
    Wu Ning
    Wu Bingwei
    Liu Yan
    Cao Xuan
    Wang Qian
    JOURNAL OF OCEAN UNIVERSITY OF CHINA, 2015, 14 (03) : 471 - 474