Development of negative-group-delay circuit for high-frequency ultrasonic transducer applications

被引:26
|
作者
Choi, Hojong [1 ]
机构
[1] Kumoh Natl Inst Technol, Dept Med IT Convergence Engn, Gumi, South Korea
基金
新加坡国家研究基金会;
关键词
Ultrasonic transducer; Negative-group-delay circuit; Electrical impedance; TRANSMISSION-LINE; SYSTEM;
D O I
10.1016/j.sna.2019.111616
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Compared with low-frequency (<15 MHz) ultrasonic transducers, high-frequency ultrasonic transducers provide higher spatial resolutions while reducing the echo-signal amplitudes and bandwidths owing to the size reduction of the piezoelectric materials. Therefore, performance improvement of high-frequency ultrasonic transducers can enhance the performance of the whole ultrasound instrument. To improve the echo-signal quality, such as the amplitudes, signal distortions, and bandwidths, negative-group-delay circuits for high-frequency ultrasonic transducers have been applied. The components of the negative-group-delay circuit can be constructed using the measured magnitude and phase characteristics of the electrical impedances of the ultrasonic transducers. Therefore, the relationship between the negative group-delay circuit and ultrasonic transducers must be analyzed to identify the adequate components of the negative-group-delay circuit. To confirm the proposed idea, the performances of negative-group delay circuits were measured and compared. The differences in the measured phase angles of the electrical impedances between the ultrasonic transducer and the combined resistor limiter, negative-group-delay circuit, and preamplifier (including a coaxial cable) were 0.66 degrees, 1.31 degrees, and 9.45 degrees at the resonant, center, and anti-resonant frequencies, respectively (<10 degrees). The calculated and measured maximum negative group delays with the resistor limiter and preamplifier were -21.64 ns at 31.65 MHz and -17.41 ns at 27.38 MHz, respectively. To verify our concept experimentally, we performed a typical pulse-echo test using the designed negative-group-delay circuit integrated with a preamplifier and using the preamplifier alone. The peak-to-peak amplitude, pulse width, -6-dB bandwidth, and total harmonic distortions of the echo signal for the negative-group-delay circuit with the preamplifier (0.232 Vp-p, 0.36 mu s, 81.12%, and -60.72 dB, respectively) were improved compared with those for the preamplifier alone (0.154 Vp-p, 0.74 mu s, 51.98%, and -28.61 dB, respectively). Therefore, the negative-group-delay circuit is useful for improving the echo signal quality of high-frequency ultrasonic transducers. The proposed approach is simple and effective for improving the echo-signal quality of ultrasonic transducers without increasing the performance of the power amplifiers and preamplifiers. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Frequency Doubler Gate Drive Circuit Suitable for High-Frequency Applications
    Hattori, Fumiya
    Ushida, Yasuhisa
    Sumiya, Kengo
    Yanagisawa, Yuta
    Imaoka, Jun
    Noah, Mostafa
    Yamamoto, Masayoshi
    [J]. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2022, 10 (01) : 617 - 631
  • [32] Impedance matching network for high frequency ultrasonic transducer for cellular applications
    Kim, Min Gon
    Yoon, Sangpil
    Kim, Hyung Ham
    Shung, K. Kirk
    [J]. ULTRASONICS, 2016, 65 : 258 - 267
  • [33] High-frequency drive-power and frequency control for ultrasonic transducer operating at 3 MHz
    Ishikawa, J
    Mizutani, Y
    Suzuki, T
    Ikeda, H
    Yoshida, H
    [J]. IAS '97 - CONFERENCE RECORD OF THE 1997 IEEE INDUSTRY APPLICATIONS CONFERENCE / THIRTY-SECOND IAS ANNUAL MEETING, VOLS 1-3, 1997, : 900 - 905
  • [34] A Compact Negative-Group-Delay Branch-line Coupler with Equal Power Division
    Wang, Zhongbao
    Bai, Yu
    Fu, Zheng
    Liu, Hongmei
    Fang, Shaojun
    [J]. 2021 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2021), 2021, : 1472 - 1477
  • [35] SIMPLE CIRCUIT YIELDS HIGH-FREQUENCY CLOCK AND PROPAGATION DELAY CHECK
    COLT, JC
    [J]. ELECTRONIC ENGINEER, 1968, 27 (08): : 69 - &
  • [36] A Review of High-Frequency Ultrasonic Transducers for Photoacoustic Imaging Applications
    Ren, Danyang
    Li, Chiye
    Shi, Junhui
    Chen, Ruimin
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (06) : 1848 - 1858
  • [37] Reconfigurable negative group delay circuit with tunable group delay flatness
    Meng, Yuwei
    Wang, Zhongbao
    Fang, Shaojun
    Liu, Hongmei
    [J]. INTERNATIONAL JOURNAL OF RF AND MICROWAVE COMPUTER-AIDED ENGINEERING, 2022, 32 (06)
  • [38] HIGH-FREQUENCY LINEAR CIRCUIT ANALYSIS PROGRAM AND ITS APPLICATIONS
    HIGO, Y
    HIROSAKI, B
    [J]. NEC RESEARCH & DEVELOPMENT, 1975, (37-3): : 39 - 49
  • [39] Multilayered Lossy-Bandstop-Filter-Based Negative-Group-Delay RF Circuit With Broadband Input-Reflectionless Behavior
    Yang, Li
    Gomez-Garcia, Roberto
    [J]. 2021 IEEE MTT-S INTERNATIONAL WIRELESS SYMPOSIUM (IWS 2021), 2021,
  • [40] Design and Experiment of Capacitive Micromachined Ultrasonic Transducer Array for High-frequency Underwater Imaging
    Yu, Yuanyu
    Wang, Jiujiang
    Liu, Xin
    Pun, Sio H.
    Qiu, Weibao
    Zhang, Shuang
    Cheng, Ching H.
    Lei, Kin F.
    Vai, Mang, I
    Mak, Peng U.
    [J]. RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2021, 14 (02) : 233 - 240