Digital background calibration of pipeline ADC with open-loop gain stage

被引:0
|
作者
Tavassoli, B. [1 ]
Shoaei, O. [1 ]
机构
[1] Univ Tehran, IC Design Lab, Dept ECE, Tehran, Iran
关键词
D O I
10.1109/ISCAS.2006.1693818
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In this work, a digital background calibration method for pipelined ADC is proposed which can compensate for the nonlinearity in amplifier gain. The proposed scheme is based on input statistical distribution property which is assumed to be known. The error correction is completely performed in digital domain. In analog domain it is only necessary to add two comparators for generating calibration threshold. Results show an improvement of 16 dB in SNDR for a nonlinear gain stage designed in a 1.5 V supply and 0.35 mu m CMOS Technology.
引用
收藏
页码:5255 / +
页数:2
相关论文
共 50 条
  • [31] SAR plus ΔΣ ADC with Open-Loop Integrator using Dynamic Amplifier
    Matsuzawa, Akira
    Miyahara, Masaya
    2017 IEEE 12TH INTERNATIONAL CONFERENCE ON ASIC (ASICON), 2017, : 24 - 27
  • [32] A Simple Background Interstage Gain Calibration Technique for Pipeline ADCs
    Tahmasebi, A.
    Kamali, A.
    Kanani, Z. D. Koozeh
    Sobhi, J.
    PROCEEDINGS OF THE 2009 INTERNATIONAL CONFERENCE ON SIGNAL ACQUISITION AND PROCESSING, 2009, : 221 - +
  • [33] Background Digital Calibration of Comparator Offsets in Pipeline ADCs
    Gines, Antonio Jose
    Peralias, Eduardo
    Rueda, Adoracion
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2015, 23 (07) : 1345 - 1349
  • [34] A Simple Background Interstage Gain Calibration Technique for Pipeline ADCs
    Sobhi, Jafar
    Kanani, Ziaeddin Koozeh
    Tahmasebi, Ahmad
    Yousefi, Mousa
    ECTI-CON: 2009 6TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY, VOLS 1 AND 2, 2009, : 479 - +
  • [35] Digital background gain error correction in pipeline ADCs
    Ginés, AJ
    Peralías, EJ
    Rueda, A
    DESIGN, AUTOMATION AND TEST IN EUROPE CONFERENCE AND EXHIBITION, VOLS 1 AND 2, PROCEEDINGS, 2004, : 82 - 87
  • [36] BLOOD-VOLUME AND OPEN-LOOP GAIN OF THE CAROTID BAROREFLEX
    LUDBROOK, J
    FARIS, IB
    JAMIESON, GG
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1982, 9 (05) : 518 - 519
  • [37] Enhancing the Accuracy for the Open-loop Resolver to Digital Converters
    Karabeyli, Fikret Anil
    Alkar, Ali Ziya
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2018, 13 (01) : 192 - 200
  • [38] System Design of AC Open-loop Gain Measurement of Amplifier
    Tian Tian
    An Na
    Zhao Xu-min
    Zeng Li-na
    Yu Tao
    MEASUREMENT TECHNOLOGY AND ENGINEERING RESEARCHES IN INDUSTRY, PTS 1-3, 2013, 333-335 : 230 - +
  • [39] POSITIVE FEEDBACK RAISES OPEN-LOOP GAIN OF OPERATIONAL AMPLIFIERS
    JORDAN, JR
    CONTROL, 1967, 11 (106): : 164 - &
  • [40] Digital Background-Calibration Algorithm for "Split ADC" Architecture
    McNeill, John A.
    Coln, Michael C. W.
    Brown, D. Richard
    Larivee, Brian J.
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2009, 56 (02) : 294 - 306