Predicting Future Hip Fractures on Routine Abdominal CT Using Opportunistic Osteoporosis Screening Measures: A Matched Case-Control Study

被引:47
|
作者
Lee, Scott J. [1 ]
Anderson, Paul A. [2 ]
Pickhardt, Perry J. [1 ]
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Wisconsin Inst Med Res, Dept Radiol, 2458 H,1111 Highland Ave, Madison, WI 53705 USA
[2] Univ Wisconsin, Sch Med & Publ Hlth, Dept Orthoped & Rehabil, Madison, WI USA
关键词
asynchronous quantitative CT; hip fracture; L1; attenuation; opportunistic osteoporosis screening; osteoporosis; BONE-MINERAL DENSITY; COMPUTED-TOMOGRAPHY; TRABECULAR BONE; ATTENUATION; DXA; COLONOGRAPHY; FEMUR; WOMEN; SPINE; SCORE;
D O I
10.2214/AJR.17.17820
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Hip fracture is a major consequence of low bone mineral density, which is treatable but underdiagnosed. The purpose of this case-control study is to determine whether lumbar vertebral trabecular attenuation, vertebral compression fractures, and femoral neck T scores readily derived from abdominopelvic CT scans obtained for various indications are associated with future hip fragility fracture. MATERIALS AND METHODS. A cohort of 204 patients with hip fracture (130 women and 74 men; mean age, 74.3 years) who had undergone abdominopelvic CT before fracture occurred (mean interval, 24.8 months) was compared with an age-and sex-matched control cohort without hip fracture. L1 trabecular attenuation, vertebral compression fractures of grades 2 and 3, and femoral neck T scores derived from asynchronous quantitative CT were recorded. The presence of one or more clinical risk factor for fracture was also recorded. Multivariate logistic regression models were used to determine the association of each measurement with the occurrence of hip fracture. RESULTS. The mean L1 trabecular attenuation value, the presence of one or more vertebral compression fracture, and CT-derived femoral neck T scores were all significantly different in patients with hip fracture versus control subjects (p < 0.01). Logistic regression models showed a significant association of all measurements with hip fracture outcome after adjustments were made for age, sex, and the presence of one or more clinical risk factor. L1 trabecular attenuation and CT-derived femoral neck T scores showed moderate accuracy in differentiating case and control patients (AUC, 0.70 and 0.78, respectively). CONCLUSION. L1 trabecular attenuation, CT-derived femoral neck T scores, and the presence of at least one vertebral compression fracture on CT are all associated with future hip fragility fracture in adults undergoing routine abdominopelvic CT for a variety of conditions.
引用
收藏
页码:395 / 402
页数:8
相关论文
共 50 条
  • [31] Pregnancy-associated transient osteoporosis of the hip: results of a case-control study
    Peyman Hadji
    Jelena Boekhoff
    Melitta Hahn
    Lars Hellmeyer
    Olaf Hars
    Ioannis Kyvernitakis
    [J]. Archives of Osteoporosis, 2017, 12
  • [32] Pregnancy-associated transient osteoporosis of the hip: results of a case-control study
    Hadji, Peyman
    Boekhoff, Jelena
    Hahn, Melitta
    Hellmeyer, Lars
    Hars, Olaf
    Kyvernitakis, Ioannis
    [J]. ARCHIVES OF OSTEOPOROSIS, 2017, 12 (01)
  • [33] Abdominal subcutaneous obesity and the risk of burst abdomen: a matched case-control study
    Kvist, Madeline
    Burcharth, Jakob
    Nielsen, Yousef Wirenfeldt
    Jensen, Thomas Korgaard
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2022, 407 (08) : 3719 - 3726
  • [34] Stress measures in tail biters and bitten pigs in a matched case-control study
    Munsterhjelm, C.
    Brunberg, E.
    Heinonen, M.
    Keeling, L.
    Valros, A.
    [J]. ANIMAL WELFARE, 2013, 22 (03) : 331 - 338
  • [35] STUDY OF THE PREVALENCE AND PREDICTING FACTORS OF OSTEOPOROSIS IN PATIENTS WITH SYSTEMIC SCLEROSIS: A CASE-CONTROL STUDY
    Marot, M.
    Valery, A.
    Esteve, E.
    Bens, G.
    Mueller, A.
    Rist, S.
    Lespessailles, E.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2014, 73 : 710 - 710
  • [36] Relationship Between Acetabular Hounsfield Unit Values and Periprosthetic Fractures in Cementless Total Hip Arthroplasty: A Matched Case-Control Study
    Nishi, Masanori
    Okano, Ichiro
    Yoshikawa, Yasushi
    Tochio, Hidenori
    Usui, Yuki
    Inagaki, Katsunori
    [J]. ARTHROPLASTY TODAY, 2022, 14 : 216 - 222.e1
  • [37] Tea drinking habits and osteoporotic hip/femur fractures: A case-control study
    Huang, Chenshu
    Tang, Rongrui
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2016, 32 (02) : 408 - 412
  • [38] CASE-CONTROL STUDY OF RISK-FACTORS FOR HIP-FRACTURES IN THE ELDERLY
    CUMMING, RG
    KLINEBERG, RJ
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 1994, 139 (05) : 493 - 503
  • [39] Opportunistic Screening for Acute Vertebral Fractures on a Routine Abdominal or Chest Computed Tomography Scans Using an Automated Deep Learning Model
    Kim, Ye Rin
    Yoon, Yu Sung
    Cha, Jang Gyu
    [J]. DIAGNOSTICS, 2024, 14 (07)
  • [40] CT of acute rejection after liver transplantation: a matched case-control study
    Jang, Jong Keon
    Kim, Kyoung Won
    Choi, Sang Hyun
    Jeong, So Yeong
    Kim, Ji Hun
    Yu, Eun Sil
    Kwon, Jae Hyun
    Song, Gi Won
    Lee, Sung Gyu
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (07) : 3736 - 3745