Determination of normal values of full-field electroretinogram in Poodle dogs with cataract according to age

被引:2
|
作者
Vaz Safatle, Angelica de Mendonca [1 ]
Lisak, Ricardo [1 ]
Otsuki, Denise Aya [1 ]
Gomes, Debora [1 ]
机构
[1] Clin Vetmasters, BR-01415004 Sao Paulo, Brazil
来源
CIENCIA RURAL | 2010年 / 40卷 / 03期
关键词
dog; Poodle; cataract; electroretinogram; ELECTRODE; CATS;
D O I
10.1590/S0103-84782010000300014
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Electroretinogram (ERG) is an objective and noninvasive diagnostic tool for the evaluation of retinal function, capable to detect early, lesions of the outermost layers in several species of animals. One of its main indications is to evaluate pre-surgical patients for cataract surgery. The determination of normal ERG values is essential if the aim is, by measuring the values; aid the diagnosis of retinal degeneration, despite of the presence of media opacity (cataract). The objective of this study was to standardize the values of electroretinogram responses in Poodle dogs with mature or hypermature cataract, submitted to the same sedation and dark adaptation protocol. using a portable electrodiagnostic system, RPM 200. In all animals, the ophthalmologic examination preceded ERG. Animals were divided into four groups according to age: 1 to 3 years (GI), 4 to 7 years (GII), 8 to 11 years (GIII) and 12 or more years (GIV). Peak-to-peak amplitude (peak of a-wave to peak of b-wave) and b-wave implicit time were measured in rod response and in maximal response and cone response. Dogs with decreased or absent responses were excluded from the study. GI presented decrease in amplitudes of the three responses and increase in b-wave implicit time of rod response when compared with the other groups. B-wave implicit times in maximal response and cone response were practically unaltered in all four groups. It was concluded that there was age-dependent changes in electroretinographic parameters, with decreased amplitudes in rod response, maximal response and Colic response. Delay in b-wave implicit time was observed in rod response and unchanged in the two others tested responses of animals subjected to the same ERG protocol.
引用
收藏
页码:587 / 593
页数:7
相关论文
共 50 条
  • [31] Full-field electroretinogram and multifocal electroretinogram in carrier of sex-linked and autosomal resessive retinitis pigmentosa.
    Cheung, SC
    Lam, TS
    Leung, KW
    To, CH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S894 - S894
  • [32] Interocular amplitude differences of the full field electroretinogram in normal subjects
    Rotenstreich, Y
    Fishman, GA
    Anderson, RJ
    Birch, DG
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (10) : 1268 - 1271
  • [33] CORNEAL FULL-FIELD ELECTRORETINOGRAMS - A STUDY OF NORMAL HUMANS
    CHATRIAN, GE
    LETTICH, E
    NELSON, PL
    EDWARDS, LK
    HAUKASS, JH
    MILLS, RP
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1986, 64 (04): : P84 - P84
  • [34] The full-field temporal contrast sensitivity test for glaucoma: influence of cataract
    A. G. M. Jünemann
    Folkert Kurt Horn
    Peter Martus
    Matthias Korth
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2000, 238 : 427 - 432
  • [35] The full-field temporal contrast sensitivity test for glaucoma:: influence of cataract
    Jünemann, AGM
    Horn, FK
    Martus, P
    Korth, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (05) : 427 - 432
  • [36] Effect of pupil size on fixed-luminance flicker full-field electroretinogram magnitude
    Mobasserian, Azadeh
    Halim, Muhammad
    Hwang, Jacklyn
    Regenold, Jonathan
    Akhavanrezayat, Amir
    Ghoraba, Hashem
    Matsumiya, Wataru
    Yavari, Negin
    Karaca, Irmak
    Yasar, Cigdem
    Lajevardi, Sherin
    Pham, Brandon
    Do, Diana
    Quan Dong Nguyen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [37] Full-field and multifocal electroretinogram in non-diabetic controls and diabetics with and without retinopathy
    Ba-Ali, Shakoor
    Larsen, Michael
    Andersen, Henrik Ullits
    Lund-Andersen, Henrik
    ACTA OPHTHALMOLOGICA, 2022, 100 (08) : E1719 - E1728
  • [38] Correlation between genotype and retinal alterations in aniridia as measured with the full-field and multifocal electroretinogram
    Poloschek, CM
    Williamson, K
    van Heyningen, V
    Wildhardt, G
    Lorenz, B
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [39] Picture Quality According to the Type of Detector in Full-field Digital Mammography
    Kim, Hyun-Soo
    Jeong, Jae-Ho
    Lee, Jong-Woong
    Kang, Hee-Doo
    Dong, Kyung-Rae
    Chung, Woon-Kwan
    Kim, Eun-Soo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 58 (02) : 364 - 371
  • [40] The full-field temporal contrast-sensitivity test for glaucoma - Influence of cataract
    Junemann, A
    Horn, F
    Budde, WM
    Mardin, CY
    Korth, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2327 - 2327