Gold nanoparticles as dose-enhancement agent for kilovoltage X-ray therapy of melanoma

被引:14
|
作者
Kim, So-Ra [1 ]
Kim, Eun-Hee [1 ]
机构
[1] Seoul Natl Univ, Radiat Bioengn Lab, Dept Nucl Engn, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Gold nanoparticle; dose-enhancement agent; kilovoltage X-rays; melanoma; skin cancer; NANOSCALE ENERGY DEPOSITION; RADIATION-THERAPY; RADIOTHERAPY; CANCER; SIZE; CYTOTOXICITY; RECEPTOR; CELLS;
D O I
10.1080/09553002.2017.1276309
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: Melanoma is mainly treated by surgery and rarely with radiation because of the high radioresistance of this tumor. Nevertheless, radiotherapy is the preferred treatment modality for unresectable lesions and avoiding cosmetic disfigurement caused by surgical excision. This study investigated the therapeutic advantage of gold nanoparticles (AuNPs) for kilovoltage X-ray treatment of melanoma.Materials and methods: Commercial AuNPs were evaluated for cytotoxicity and cellular internalization. The sensitivity of human skin melanoma cells to 150 and 450 kVp X-ray exposure was assessed in terms of clonogenicity with or without spherical AuNP treatment.Results: AuNP treatment elicited dose enhancement effect on melanoma cells exposed to kilovoltage X-rays. Treatment with 320M 50nm AuNPs before exposure to 150 kVp X-rays at 2Gy resulted in clonogenic cell death equivalent to that caused by 4.3Gy X-rays without AuNP treatment.Conclusion: AuNPs of 50nm in size can regulate melanoma cells in kilovoltage X-ray treatment by functioning as dose-enhancement agent and thus improving radioresponse of the cells. Melanomas of stages T1-T3 gain therapeutic benefits from 150 kVp X-ray treatment.
引用
收藏
页码:517 / 526
页数:10
相关论文
共 50 条
  • [21] SURFACE DOSE ESTIMATION BY A KAP METER FOR KILOVOLTAGE X-RAY BEAMS
    Araki, F.
    Umeno, S.
    RADIATION PROTECTION DOSIMETRY, 2021, 195 (02) : 124 - 131
  • [22] Study of the gadolinium salt dose-enhancement In vitro effect as a promising agent for neutron capture therapy
    Anikin, M.
    Plotnikov, E.
    Zhuk, V.
    Smolnikov, N.
    Lebedev, I.
    Naymushin, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S422 - S423
  • [23] Use of calculations to validate beam quality and relative dose measurements for a kilovoltage X-ray therapy unit
    B. J. Healy
    R. F. Hill
    Physical and Engineering Sciences in Medicine, 2022, 45 : 537 - 546
  • [24] Application of gold nanoparticles to X-ray diagnostics and photothermal therapy of cancer
    Terentyuk, G. S.
    Maksimova, I. L.
    Tuchin, V. V.
    Zharov, V. P.
    Khlebtsov, B. N.
    Bogatyrev, V. A.
    Dykman, L. A.
    Khlebtsov, N. G.
    SARATOV FALL MEETING 2006: COHERENT OPTICS OF ORDERED AND RANDOM MEDIA VII, 2007, 6536
  • [25] Use of calculations to validate beam quality and relative dose measurements for a kilovoltage X-ray therapy unit
    Healy, B. J.
    Hill, R. F.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (02) : 537 - 546
  • [26] Monte Carlo simulations of dose enhancement around gold nanoparticles used as X-ray imaging contrast agents and radiosensitizers
    Li, W. B.
    Muellner, M.
    Greiter, M. B.
    Bissardon, C.
    Xie, W. Z.
    Schlattl, H.
    Oeh, U.
    Li, J. L.
    Hoeschen, C.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [27] Measurement of X-ray relative dose-enhancement factor for CMOS device using bi-laminate structure and its simulation
    Guo, Hong-Xia
    Chen, Yu-Sheng
    Zhang, Yi-Men
    Zhou, Hui
    Wu, Guo-Rong
    Lin, Dong-Sheng
    Han, Fu-Bin
    Guan, Ying
    Gong, Jian-Cheng
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 2002, 22 (01):
  • [28] A Novel attachment system for cutouts in kilovoltage X-ray beam therapy
    Baumgartl, M.
    Kohler, G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 872 - 872
  • [29] A novel attachment system for cutouts in kilovoltage x-ray beam therapy
    Baumgartl, M.
    Kohler, G.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S813 - S813
  • [30] Experimental validation of a kilovoltage x-ray source model for computing imaging dose
    Poirier, Yannick
    Kouznetsov, Alexei
    Koger, Brandon
    Tambasco, Mauro
    MEDICAL PHYSICS, 2014, 41 (04)