Quasimonochromatic x-ray computed tomography by the balanced filter method using a conventional x-ray source

被引:14
|
作者
Saito, M [1 ]
机构
[1] Niigata Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol, Niigata 9518518, Japan
关键词
computed tomography; quasimonochromatic x ray; balanced filters; linear attenuation coefficients;
D O I
10.1118/1.1819553
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A quasi monochromatic x-ray computed tomography (CT) system utilizing balanced filters has recently been developed for acquiring quantitative CT images. This system consisted of basic components such as a conventional x-ray generator for radiography, a stage for mounting and rotating objects, and an x-ray line sensor camera. Metallic sheets of Er and Yb were used as the balanced filters for obtaining quasi monochromatic incident x rays that include the characteristic lines of the W Kalpha doublet from a tungsten target. The mean energy and energy width of the quasimonochromatic x rays were determined to be 59.0 and 1.9 keV, respectively, from x-ray spectroscopic measurements using a high-purity Ge detector. The usefulness of the present x-ray CT system was demonstrated by obtaining spatial distributions of the linear attenuation coefficients of three selected samples-a 20 cm diameter cylindrical water phantom, a 3.5 cm diameter aluminum rod, and a human head phantom. The results clearly indicate that this apparatus is surprisingly effective for estimating, the distribution of the linear attenuation coefficients without any correction of the beam-hardening effect. Thus, implementing the balanced filter method on an x-ray CT scanner has promise in producing highly quantitative CT images. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:3436 / 3443
页数:8
相关论文
共 50 条
  • [31] X-Ray Acoustic Computed Tomography (XACT): 100% Sensitivity to X-Ray Absorption
    Xiang, L.
    Ahmad, M.
    Nikoozadeh, A.
    Pratx, G.
    Khuri-Yakub, B.
    Xing, L.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [32] Collimated superfine x-ray beam based x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Lun, Michael
    Li, Changqing
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (06) : 945 - 957
  • [33] Evaluation of joined silicon nitride by X-ray computed tomography (X-ray CT)
    Kondo, Naoki
    Nishimura, Yoshihiro
    Suzuki, Takayuki
    Kita, Hideki
    JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 2010, 118 (1384) : 1192 - 1194
  • [34] Polarized x-ray excitation for scatter reduction in x-ray fluorescence computed tomography
    Vernekohl, Don
    Tzoumas, Stratis
    Zhao, Wei
    Xing, Lei
    MEDICAL PHYSICS, 2018, 45 (08) : 3741 - 3748
  • [35] LYMPHOGRANULOMATOSIS - DIAGNOSIS BY CONVENTIONAL X-RAY EXAMINATIONS AND COMPUTED-TOMOGRAPHY
    GUNTHER, R
    WOLFF, P
    STRAHLENTHERAPIE, 1985, 161 (05) : 257 - 263
  • [36] Method to calculate frequency characteristics of reconstruction filter kernel in X-ray computed tomography
    Sato, Kazuhiro
    Tomita, Yu
    Kageyama, Ryota
    Takane, Yumi
    Kayano, Shingo
    Saito, Haruo
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (01) : 69 - 78
  • [37] Method to calculate frequency characteristics of reconstruction filter kernel in X-ray computed tomography
    Kazuhiro Sato
    Yu Tomita
    Ryota Kageyama
    Yumi Takane
    Shingo Kayano
    Haruo Saito
    Physical and Engineering Sciences in Medicine, 2020, 43 : 69 - 78
  • [38] Non-destructive method for wood identification using conventional X-ray computed tomography data
    Kobayashi, Kayoko
    Hwang, Sung-Wook
    Okochi, Takayuki
    Lee, Won-Hee
    Sugiyama, Junji
    JOURNAL OF CULTURAL HERITAGE, 2019, 38 : 88 - 93
  • [39] An analytical simulation method for X-ray fluorescence computed tomography
    Gao, Bo
    Laforce, Brecht
    Dhaene, Jelle
    Vincze, Laszlo
    Van Hoorebeke, Luc
    Boone, Matthieu N.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 170 (170)
  • [40] A general method for motion compensation in x-ray computed tomography
    Biguri, Ander
    Dosanjh, Manjit
    Hancock, Steven
    Soleimani, Manuchehr
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (16): : 6532 - 6549