Quasimonochromatic x-ray computed tomography by the balanced filter method using a conventional x-ray source

被引:14
|
作者
Saito, M [1 ]
机构
[1] Niigata Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol, Niigata 9518518, Japan
关键词
computed tomography; quasimonochromatic x ray; balanced filters; linear attenuation coefficients;
D O I
10.1118/1.1819553
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A quasi monochromatic x-ray computed tomography (CT) system utilizing balanced filters has recently been developed for acquiring quantitative CT images. This system consisted of basic components such as a conventional x-ray generator for radiography, a stage for mounting and rotating objects, and an x-ray line sensor camera. Metallic sheets of Er and Yb were used as the balanced filters for obtaining quasi monochromatic incident x rays that include the characteristic lines of the W Kalpha doublet from a tungsten target. The mean energy and energy width of the quasimonochromatic x rays were determined to be 59.0 and 1.9 keV, respectively, from x-ray spectroscopic measurements using a high-purity Ge detector. The usefulness of the present x-ray CT system was demonstrated by obtaining spatial distributions of the linear attenuation coefficients of three selected samples-a 20 cm diameter cylindrical water phantom, a 3.5 cm diameter aluminum rod, and a human head phantom. The results clearly indicate that this apparatus is surprisingly effective for estimating, the distribution of the linear attenuation coefficients without any correction of the beam-hardening effect. Thus, implementing the balanced filter method on an x-ray CT scanner has promise in producing highly quantitative CT images. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:3436 / 3443
页数:8
相关论文
共 50 条
  • [21] X-ray computed tomography of the heart
    Wijesekera, Nevin T.
    Duncan, Mark K.
    Padley, Simon P. G.
    BRITISH MEDICAL BULLETIN, 2010, 93 (01) : 49 - 67
  • [22] Dose in x-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : R129 - R150
  • [23] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [24] X-Ray Tomography as a Diagnostic Method of X-Ray Refractive Optics
    Narikovich, A. S.
    Ershov, P. A.
    Leitsin, V. N.
    Savin, V. V.
    Snigirev, A. A.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2017, 60 (03) : 390 - 393
  • [25] DOSE REDUCTION IN X-RAY COMPUTED-TOMOGRAPHY USING A GENERALIZED FILTER
    REED, IS
    GLENN, WV
    CHANG, CM
    TRUONG, TK
    KWOH, YS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) : 2904 - 2909
  • [26] X-ray tomography as a diagnostic method of X-ray refractive optics
    A. S. Narikovich
    P. A. Ershov
    V. N. Leitsin
    V. V. Savin
    A. A. Snigirev
    Instruments and Experimental Techniques, 2017, 60 : 390 - 393
  • [27] X-ray source translation based computed tomography (STCT)
    Yu, Haijun
    Li, Lei
    Tan, Chuandong
    Liu, Fenglin
    Zhou, Rifeng
    OPTICS EXPRESS, 2021, 29 (13) : 19743 - 19758
  • [28] Rudist taxonomy using X-ray computed tomography
    Molineux, Ann
    Scott, Robert W.
    Ketcham, Richard A.
    Maisano, Jessica A.
    PALAEONTOLOGIA ELECTRONICA, 2007, 10 (03):
  • [29] VIRTUAL UNROLLING USING X-RAY COMPUTED TOMOGRAPHY
    Allegra, D.
    Ciliberto, E.
    Ciliberto, P.
    Milotta, F. L. M.
    Petrillo, G.
    Stanco, F.
    Trombatore, C.
    2015 23RD EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2015, : 2864 - 2868
  • [30] DEMONSTRATION OF PHASE-CONTRAST X-RAY COMPUTED-TOMOGRAPHY USING AN X-RAY INTERFEROMETER
    MOMOSE, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 352 (03): : 622 - 628