Iterative reconstruction or filtered back-projection for quantitative assessment of dopamine D2 receptor SPECT studies?

被引:0
|
作者
Hamann, CS
Koch, W
Radau, P
Tatsch, K
机构
[1] Univ Munich, Dept Nucl Med, D-80539 Munich, Germany
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
372
引用
收藏
页码:114P / 114P
页数:1
相关论文
共 50 条
  • [21] An investigation of spatial resolution and noise in reconstructed CT images using iterative reconstruction (IR) and filtered back-projection (FBP)
    Anam, C.
    Haryanto, F.
    Widita, R.
    Arif, I.
    Dougherty, G.
    6TH INTERNATIONAL CONFERENCE ON MATHEMATICS AND NATURAL SCIENCES, 2019, 1127
  • [22] Investigation of the quantitative accuracy of 3D iterative reconstruction algorithms in comparison to filtered back projection method: a phantom study
    Abuhadi, Nouf
    Bradley, David
    Katarey, Dev
    Podolyak, Zsolt
    Sassi, Salem
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [23] Iterative Reconstruction in Head CT: Image Quality of Routine and Low-Dose Protocols in Comparison with Standard Filtered Back-Projection
    Korn, A.
    Fenchel, M.
    Bender, B.
    Danz, S.
    Hauser, T. K.
    Ketelsen, D.
    Flohr, T.
    Claussen, C. D.
    Heuschmid, M.
    Ernemann, U.
    Brodoefel, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (02) : 218 - 224
  • [24] Quantitative Comparison of Noise Texture in Gemstone Spectrum Imaging CT Images Reconstructed Using Filtered Back-Projection (FBP), Iterative Reconstruction, and Deep Learning Techniques
    Tang, J.
    Nett, B.
    Prakash, P.
    MEDICAL PHYSICS, 2020, 47 (06) : E399 - E399
  • [25] Automated evaluation of dopamine D2 receptor SPECT studies: Benefit in clinical routine?
    Hamann, CS
    Koch, W
    Radau, P
    Tatsch, K
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 261P - 262P
  • [26] Comparison of filtered back projection and iterative reconstruction in diagnosing appendicitis at 2-mSv CT
    Park, Ji Hoon
    Kim, Bohyoung
    Kim, Mi Sung
    Kim, Hyuk Jung
    Ko, Yousun
    Ahn, Soyeon
    Karul, Murat
    Fletcher, Joel G.
    Lee, Kyoung Ho
    ABDOMINAL RADIOLOGY, 2016, 41 (07) : 1227 - 1236
  • [27] Comparison of filtered back projection and iterative reconstruction in diagnosing appendicitis at 2-mSv CT
    Ji Hoon Park
    Bohyoung Kim
    Mi Sung Kim
    Hyuk Jung Kim
    Yousun Ko
    Soyeon Ahn
    Murat Karul
    Joel G. Fletcher
    Kyoung Ho Lee
    Abdominal Radiology, 2016, 41 : 1227 - 1236
  • [28] Comparison of Iterative Model Reconstruction versus Filtered Back-Projection in Pediatric Emergency Head CT: Dose, Image Quality, and Image-Reconstruction Times
    Southard, R. N.
    Bardo, D. M. E.
    Temkit, M. H.
    Thorkelson, M. A.
    Augustyn, R. A.
    Martinot, C. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) : 866 - 871
  • [29] Fluorescent optical imaging of small animals using filtered back-projection 3D surface reconstruction method
    Hu, Gang
    Yao, Junjie
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 76 - 80
  • [30] Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Ji Yung Choo
    Jin Mo Goo
    Chang Hyun Lee
    Chang Min Park
    Sang Joon Park
    Mi-Suk Shim
    European Radiology, 2014, 24 : 799 - 806