Implementation of absolute quantification in small-animal SPECT imaging: Phantom and animal studies

被引:6
|
作者
Gerdekoohi, Shabnam Khorasani [1 ,2 ]
Vosoughi, Naser [1 ]
Tanha, Kaveh [3 ]
Assadi, Majid [3 ]
Ghafarian, Pardis [4 ,5 ]
Rahmim, Arman [6 ,7 ]
Ay, Mohammad Reza [2 ,8 ]
机构
[1] Sharif Univ Technol, Dept Energy Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Bushehr Univ Med Sci, Persian Gulf Nucl Med Res Ctr, Bushehr, Iran
[4] Shahid Beheshti Univ Med Sci, Natl Res Inst TB & Lung Dis NRITLD, Chron Resp Dis Res Ctr, Tehran, Iran
[5] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, PET CT & Cyclotron Ctr, Tehran, Iran
[6] Johns Hopkins Univ, Dept Radiol, Baltimore, MD USA
[7] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
[8] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
来源
关键词
attenuation correction; quantification; small-animal imaging; SPECT imaging; PARTIAL VOLUME CORRECTION; HIGH-RESOLUTION; PERFORMANCE EVALUATION; ATTENUATION CORRECTION; SYSTEM; TOMOGRAPHY; PINHOLE; PET; RECONSTRUCTION; ACCURACY;
D O I
10.1002/acm2.12094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Presence of photon attenuation severely challenges quantitative accuracy in single-photon emission computed tomography (SPECT) imaging. Subsequently, various attenuation correction methods have been developed to compensate for this degradation. The present study aims to implement an attenuation correction method and then to evaluate quantification accuracy of attenuation correction in small-animal SPECT imaging. Methods: Images were reconstructed using an iterative reconstruction method based on the maximum-likelihood expectation maximization (MLEM) algorithm including resolution recovery. This was implemented in our designed dedicated small-animal SPECT (HiReSPECT) system. For accurate quantification, the voxel values were converted to activity concentration via a calculated calibration factor. An attenuation correction algorithm was developed based on the first-order Chang's method. Both phantom study and experimental measurements with four rats were used in order to validate the proposed method. Results: The phantom experiments showed that the error of -15.5% in the estimation of activity concentration in a uniform region was reduced to +5.1% when attenuation correction was applied. For in vivo studies, the average quantitative error of -22.8 +/- 6.3% (ranging from -31.2% to -14.8%) in the uncorrected images was reduced to +3.5 +/- 6.7% (ranging from -6.7 to +9.8%) after applying attenuation correction. Conclusion: The results indicate that the proposed attenuation correction algorithm based on the first-order Chang's method, as implemented in our dedicated small-animal SPECT system, significantly improves accuracy of the quantitative analysis as well as the absolute quantification.
引用
收藏
页码:215 / 223
页数:9
相关论文
共 50 条
  • [1] Absolute Quantification for Small-Animal PET
    Keereman, Vincent
    Van Holen, Roel
    Vanhove, Christian
    Mollet, Pieter
    Vandenberghe, Stefaan
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3715 - 3719
  • [2] A fluorescent phantom for small-animal imaging
    Purdue University
    不详
    不详
    不详
    不详
    [J]. Biophoton Int, 2007, 4 (30-35):
  • [3] Cardiac Phantom for Improved Small-Animal SPECT Myocardial Blood Flow Quantification
    Johnson, Lindsay C.
    Guerraty, Marie A.
    Matej, David J.
    Metzler, Scott D.
    [J]. 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [4] Evaluation of Quantitative Accuracy of Tc-99m Small-Animal SPECT Imaging in Phantom Studies
    Gerdekoohi, S. Khorasani
    Vosoughi, N.
    Tanha, K.
    Assadi, M.
    Ay, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S475 - S475
  • [5] Small-animal SPECT dynamic cardiac imaging
    Johnson, Lindsay
    Guerraty, Marie
    Blankemeyer, Eric
    Mankoff, David
    Rader, Daniel
    Metzler, Scott
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [6] Quantification of myocardial uptake rate constants in dynamic small-animal SPECT using a cardiac phantom
    Johnson, Lindsay C.
    Guerraty, Marie A.
    Moore, Stephen C.
    Metzler, Scott D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06):
  • [7] High-resolution SPECT for small-animal imaging
    QI Yu-Jin (Shanghai Institute of Applied Physics
    [J]. Nuclear Science and Techniques, 2006, (03) : 164 - 169
  • [8] Compact CT/SPECT small-animal imaging system
    Kastis, GA
    Furenlid, LR
    Wilson, DW
    Peterson, TE
    Barber, HB
    Barrett, HH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 63 - 67
  • [9] Compact CT/SPECT small-animal imaging system
    Kastis, GA
    Furenlid, LR
    Wilson, DW
    Peterson, TE
    Barber, HB
    Barrett, HH
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 797 - 801
  • [10] Implementation and assessment of an animal management system for small-animal micro-CT/micro-SPECT imaging
    Holdsworth, David W.
    Detombe, Sarah A.
    Chiodo, Chris
    Fricke, Stanley T.
    Drangova, Maria
    [J]. MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965