Absolute Quantification for Small-Animal PET

被引:0
|
作者
Keereman, Vincent [1 ]
Van Holen, Roel [1 ]
Vanhove, Christian [1 ]
Mollet, Pieter [1 ]
Vandenberghe, Stefaan [1 ]
机构
[1] Univ Ghent, Dept Elect & Informat Syst, IBBT IBiTech, MEDISIP, B-9000 Ghent, Belgium
关键词
micro-PET; micro-CT; quantification; attenuation correction; POSITRON-EMISSION-TOMOGRAPHY; TUMOR RESPONSE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Quantification is important in preclinical PET studies. To achieve absolute quantification, an accurate reconstruction algorithm is necessary. Such an algorithm includes corrections for different effects such as geometric sensitivity of the scanner, detection efficiency, attenuation, scatter and random coincidences. In this work we present a method for performing absolute quantification on the LabPET system. All acquisitions were done on a GE Triumph system. This tri-modality system consists of a micro-PET (LabPET), micro-CT (X-O) and micro-SPECT (X-SPECT) scanner. Three PET scans were done. In the first scan 5 vials with different activity concentrations of F-18-FDG were scanned. The total activity inside the scanner was 80 MBq. The second scan was performed after 4 hours when the total activity in the scanner had decayed to 20 MBq. In the third scan 3 vials and 1 sphere were scanned with a total activity of 20 MBq. Before each PET scan a micro-CT scan was acquired. Point sources with a known activity were placed inside the field of view. The counts obtained in these point sources are used to obtain a correction factor for absolute sensitivity. Reconstruction was done using a 3D ML-EM reconstruction with micro-CT based attenuation correction. VOIs were drawn over the vials and the sphere in the reconstructed images. The total activity in the VOIs was calculated using the correction factor for absolute sensitivity. It was compared to the activity measured in a dose calibrator. The average quantification error was 56 %, 6.4 % and 0.6 % for the first, second and third scan. The high error in the first scan is explained by count rate effects, as 80 MBq can be considered a high activity level for this system. The feasibility of absolute quantification on the LabPET system was demonstrated. When the count rate is below 20 MBq absolute quantification is possible with an average quantification error smaller than 6.4 %.
引用
收藏
页码:3715 / 3719
页数:5
相关论文
共 50 条
  • [1] Implementation of absolute quantification in small-animal SPECT imaging: Phantom and animal studies
    Gerdekoohi, Shabnam Khorasani
    Vosoughi, Naser
    Tanha, Kaveh
    Assadi, Majid
    Ghafarian, Pardis
    Rahmim, Arman
    Ay, Mohammad Reza
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (04): : 215 - 223
  • [2] Small-animal PET cameras
    Jeavons, AP
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (08): : 1442 - 1443
  • [3] Innovations in Small-Animal PET Instrumentation
    Lehnert, Adrienne L.
    Miyaoka, Robert S.
    [J]. PET CLINICS, 2024, 19 (01) : 59 - 67
  • [4] Development of a small-animal PET system
    Ziegler, SI
    [J]. PROCEEDINGS OF THE IEEE, 2005, 93 (04) : 763 - 770
  • [5] Triple and dual PET quantification of a Small-Animal Multi-Pinhole PET/SPECT/CT System
    Echegoyen, P.
    Cuenca Bandin, T.
    Ecay, M.
    Prieto, E.
    Collantes, M.
    Pareja, F.
    Simon Martinez, J.
    Penuelas, I.
    Marti-Climent, J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S144 - S144
  • [6] In vivo radiolabel quantification in small-animal models
    Ploux, L
    Mastrippolito, R
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 1998, 25 (08) : 737 - 742
  • [7] Longitudinal correlations in a small-animal PET studies
    Abbey, C
    Borowsky, A
    Gregg, J
    McGoldrick, E
    Cardiff, R
    Cherry, S
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1901 - 1901
  • [8] Semiautomated analysis of small-animal PET data
    Kesner, Adam L.
    Dahlbom, Magnus
    Huang, Sung-Cheng
    Hsueh, Wei-Ann
    Pio, Betty S.
    Czernin, Johannes
    Kreissl, Michael
    Wu, Hsiao-Ming
    Silverman, Daniel H. S.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (07): : 1181 - 1186
  • [9] A new PET system for small-animal imaging
    Wilson, DW
    Furenlid, LR
    Barrett, HH
    Chen, YC
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3389 - 3392
  • [10] Small-animal PET: Advent of a new era of PET research
    Tornai, MP
    Jaszczak, RJ
    Turkington, TG
    Coleman, RE
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (07): : 1176 - 1179