Novel thermoluminescence foils for 2-D clinical dosimetry, based on CaSO4:Dy

被引:15
|
作者
Klosowski, M. [1 ]
Czopyk, L. [1 ]
Kisielewicz, K. [2 ]
Kabat, D. [2 ]
Olko, P. [1 ]
Waligorski, M. P. R. [2 ]
机构
[1] Polish Acad Sci, Inst Nucl Phys, PL-31342 Krakow, Poland
[2] Maria Sklodowska Curie Mem Inst Oncol, Ctr Oncol, PL-31115 Krakow, Poland
关键词
2-D dosimetry; CaSO4:Dy; TLD foil;
D O I
10.1016/j.radmeas.2009.12.009
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The newly developed two-dimensional thermoluminescence (TL) foils made from CaSO4:Dy TL powder and the high temperature polymer PFA, were tested for their dosimetric properties. The results were evaluated using laboratory TL reader with PCO CCD camera and round planchet heater, 72 mm in diameter. 55 x 55 x 0.3 mm(3) foils were tested for dose response, reproducibility and spatial resolution. It was found that the detectors are linear up to at least 2 Gy and their spatial resolution is about 1 mm. A loss of sensitivity with repeated re-uses was observed (9% in 10 uses). It is attributable to the darkening of the detector due to oxidizing of impurities gathering at its surface and may be avoided by application of proper cleaning procedure. The foils were tested for measurements of 2-D dose distribution on 60 MeV proton beam at IFJ Krakow. The results show that 2-D TL foils based on CaSO4:Dy can be a useful tool for quality assurance of proton beams. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:719 / 721
页数:3
相关论文
共 50 条
  • [31] THERMOLUMINESCENCE OF CaSO4:Dy - SEMIEMPIRICAL APPROACH FOR A QUALITATIVE ANALYSIS OF NONLINEAR THERMOLUMINESCENCE EFFECTS.
    Srivastava, J.K.
    Supe, S.J.
    1600, (92):
  • [32] PHOTO-TL IN CASO4 - DY - HIGH EXPOSURE DOSIMETRY
    CALDAS, LVE
    MAYHUGH, MR
    HEALTH PHYSICS, 1976, 31 (05): : 451 - 452
  • [33] Preparation of CaSO4:Dy by precipitation method to gamma radiation dosimetry
    Rivera, T.
    Roman, J.
    Azorin, J.
    Sosa, R.
    Guzman, J.
    Serrano, A. K.
    Garcia, M.
    Alarcon, G.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 623 - 625
  • [34] Multilevel based analysis of the thermoluminescence of CaSO4:RE (RE=Tm, Dy, Tb, and Sm)
    Shinsho, K
    Suzuki, Y
    Harada, K
    Yamamoto, Y
    Urushiyama, A
    JOURNAL OF APPLIED PHYSICS, 2006, 99 (04)
  • [35] THERMAL-NEUTRON DOSIMETRY WITH CADMIUM COVERED CASO4=DY
    LAKSHMANAN, AR
    BHATT, RC
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1977, 28 (07): : 665 - 666
  • [36] Application of the CaSO4:Dy phototransfer phenomenon to high temperature dosimetry
    Goyet, D
    Lapraz, D
    Iacconi, P
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 317 - 320
  • [37] Thermoluminescence studies of CaSO4:Dy nanophosphor for application in high dose measurements
    Mandlik, Nandkumar
    Dhole, S. D.
    Sahare, P. D.
    Bakare, J. S.
    Balraj, A.
    Bhatt, B. C.
    APPLIED RADIATION AND ISOTOPES, 2019, 148 : 253 - 261
  • [38] Influence of Li dopants on thermoluminescence spectra of CaSO4 doped with Dy or Tm
    Wang, Y.
    Can, N.
    Townsend, P. D.
    JOURNAL OF LUMINESCENCE, 2011, 131 (09) : 1864 - 1868
  • [39] Thermoluminescence of undoped and Dy-doped CaSO4: Influence of the preparation methods
    Gerome, V
    Iacconi, P
    Lapraz, D
    Prevost, H
    Baumer, A
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 309 - 312
  • [40] Cathodoluminescence and green-thermoluminescence response of CaSO4:Dy,P films
    Roman-Lopez, J.
    Correcher, V.
    Garcia-Guinea, J.
    Rivera, T.
    Lozano, I. B.
    JOURNAL OF LUMINESCENCE, 2013, 135 : 89 - 92