Novel thermoluminescence foils for 2-D clinical dosimetry, based on CaSO4:Dy

被引:15
|
作者
Klosowski, M. [1 ]
Czopyk, L. [1 ]
Kisielewicz, K. [2 ]
Kabat, D. [2 ]
Olko, P. [1 ]
Waligorski, M. P. R. [2 ]
机构
[1] Polish Acad Sci, Inst Nucl Phys, PL-31342 Krakow, Poland
[2] Maria Sklodowska Curie Mem Inst Oncol, Ctr Oncol, PL-31115 Krakow, Poland
关键词
2-D dosimetry; CaSO4:Dy; TLD foil;
D O I
10.1016/j.radmeas.2009.12.009
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The newly developed two-dimensional thermoluminescence (TL) foils made from CaSO4:Dy TL powder and the high temperature polymer PFA, were tested for their dosimetric properties. The results were evaluated using laboratory TL reader with PCO CCD camera and round planchet heater, 72 mm in diameter. 55 x 55 x 0.3 mm(3) foils were tested for dose response, reproducibility and spatial resolution. It was found that the detectors are linear up to at least 2 Gy and their spatial resolution is about 1 mm. A loss of sensitivity with repeated re-uses was observed (9% in 10 uses). It is attributable to the darkening of the detector due to oxidizing of impurities gathering at its surface and may be avoided by application of proper cleaning procedure. The foils were tested for measurements of 2-D dose distribution on 60 MeV proton beam at IFJ Krakow. The results show that 2-D TL foils based on CaSO4:Dy can be a useful tool for quality assurance of proton beams. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:719 / 721
页数:3
相关论文
共 50 条
  • [21] High dose measurements using thermoluminescence of CaSO4:Dy
    Naval Surface Warfare Center, Carderock Division, 9500 MacArthur Blvd, West Bethesda, MD 20817-5700, United States
    Radiat Meas, 6 (735-738):
  • [22] Thermoluminescence studies of CaSO4: Eu nanophosphor for electron dosimetry
    Mandlik, Nandkumar
    Bhoraskar, V. N.
    Patil, B. J.
    Dahiwale, S. S.
    Sahare, P. D.
    Dhole, S. D.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2017, 55 (06) : 413 - 419
  • [23] Thermoluminescence of Nanocrystalline CaSO4: Dy for Gamma Dosimetry and Calculation of Trapping Parameters using Deconvolution Method
    Mandlik, Nandkumar
    Patil, B. J.
    Bhoraskar, V. N.
    Sahare, P. D.
    Dhole, S. D.
    SOLID STATE PHYSICS: PROCEEDINGS OF THE 58TH DAE SOLID STATE PHYSICS SYMPOSIUM 2013, PTS A & B, 2014, 1591 : 369 - 371
  • [24] Evaluation of thermoluminescence of 200 keV carbon ion irradiated CaSO4:Dy nanophosphors for medical dosimetry
    Bhadane, Mahesh S.
    Akhtar, Shahzad
    Dahiwale, S. S.
    Hareesh, K.
    Asokan, K.
    Kanjilal, D.
    Bhoraskar, V. N.
    Dhole, S. D.
    JOURNAL OF LUMINESCENCE, 2017, 192 : 695 - 700
  • [25] Studies of uv induced phototransferred thermoluminescence in CaSo4:Dy pellets
    Grossi, FH
    Campos, LL
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 421 - 424
  • [26] Studies of UV induced phototransferred thermoluminescence in CaSO4:Dy pellets
    Grossi, FH
    Campos, LL
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 421 - 424
  • [28] Preliminary Studies of Thermoluminescence Dosimeter (TLD) CaSO4:Dy Synthesis
    Nuraeni, N.
    Iskandar, F.
    Waris, A.
    Haryanto, F.
    INTERNATIONAL CONFERENCE ON ENERGY SCIENCES (ICES 2016), 2017, 877
  • [29] RECENT IMPROVEMENTS IN CASO4 AND BASO4 THERMOLUMINESCENCE DOSIMETRY MATERIALS
    LAKSHMANAN, AR
    RADIATION PROTECTION DOSIMETRY, 1992, 40 (04) : 219 - 221
  • [30] Synthesis of CaSO4: Dy, CaSO4: Eu3+ and CaSO4: Eu2+ phosphors
    Ingle, N. B.
    Omanwar, S. K.
    Muthal, P. L.
    Dhopte, S. M.
    Kondawar, V. K.
    Gundurao, T. K.
    Moharil, S. V.
    RADIATION MEASUREMENTS, 2008, 43 (07) : 1191 - 1197