Voltammetric detection of damage to DNA caused by nitro derivatives of fluorene using an electrochemical DNA biosensor

被引:53
|
作者
Vyskocil, Vlastimil [1 ]
Labuda, Jan [2 ]
Barek, Jiri [1 ]
机构
[1] Charles Univ Prague, Fac Sci, Dept Analyt Chem, UNESCO Lab Environm Electrochem, Prague 12843 2, Czech Republic
[2] Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, Slovakia
关键词
2-Nitrofluorene; 2,7-Dinitrofluorene; DNA biosensor; Screen printed carbon paste electrode; Electrochemical detection; DNA damage; POLYCYCLIC AROMATIC-HYDROCARBONS; COMPOSITE ELECTRODE; SILVER; 2-NITROFLUORENE; METABOLISM; 1,10-PHENANTHROLINE; POLAROGRAPHY; FLAVONOIDS; COMPLEXES; CARBON;
D O I
10.1007/s00216-010-3517-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An electrochemical DNA biosensor based on the screen printed carbon paste electrode (SPCPE) with an immobilized layer of calf thymus double-stranded DNA has been used for in vitro investigation of the interaction between genotoxic nitro derivatives of fluorene (namely 2-nitrofluorene and 2,7-dinitrofluorene) and DNA. Two types of DNA damage have been detected at the DNA/SPCPE biosensor: first, that caused by direct association of the nitrofluorenes, for which an intercalation association has been found using the known DNA intercalators [Cu(phen)(2)](2+) and [Co(phen)(3)](3+) as competing agents, and, second, that caused by short-lived radicals generated by electrochemical reduction of the nitro group (observable under specific conditions only).
引用
收藏
页码:233 / 241
页数:9
相关论文
共 50 条
  • [41] Electrochemical DNA biosensor for polycyclic aromatic hydrocarbon detection
    Michele Del Carlo
    Manuela Di Marcello
    Monia Perugini
    Valentina Ponzielli
    Manuel Sergi
    Marcello Mascini
    Dario Compagnone
    Microchimica Acta, 2008, 163 : 163 - 169
  • [42] A novel electrochemical DNA biosensor for Ebola virus detection
    Ilkhani, Hoda
    Farhad, Siamak
    ANALYTICAL BIOCHEMISTRY, 2018, 557 : 151 - 155
  • [43] Reusable Electrochemical DNA Biosensor for the Detection of Waterborne Uranium
    Jett, Susan E.
    Bonham, Andrew J.
    CHEMELECTROCHEM, 2017, 4 (04): : 843 - 845
  • [44] DNA-based electrochemical biosensor for imipramine detection
    Jankowska-Sliwinska, Joanna
    Dawgul, Marek
    Pijanowska, Dorota G.
    EUROSENSORS 2015, 2015, 120 : 574 - 577
  • [45] Carbon nanotube-enhanced electrochemical DNA biosensor for DNA hybridization detection
    Cai, H
    Cao, XN
    Jiang, Y
    He, PG
    Fang, YZ
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (02) : 287 - 293
  • [46] Carbon nanotube-enhanced electrochemical DNA biosensor for DNA hybridization detection
    Hong Cai
    Xuni Cao
    Ying Jiang
    Pingang He
    Yuzhi Fang
    Analytical and Bioanalytical Chemistry, 2003, 375 : 287 - 293
  • [47] An impedimetric biosensor for DNA damage detection and study of the protective effect of deferoxamine against DNA damage
    Mousavisani, Seyedeh Zeinab
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Bagheryan, Zahra
    BIOELECTROCHEMISTRY, 2018, 122 : 142 - 148
  • [48] Detection of interaction between metal complex indicator and DNA by using electrochemical biosensor
    Erdem, A
    Meric, B
    Kerman, K
    Dalbasti, T
    Ozsoz, M
    ELECTROANALYSIS, 1999, 11 (18) : 1372 - 1376
  • [49] Human papilloma virus detection using DNA biosensor with electrochemical impedance spectroscopy
    Karimizefreh, Ali
    Mahyari, Farzaneh Aghakhani
    VaezJalali, Maryam
    Mohammadpour, Raheleh
    Sasanpour, Pezhman
    JOURNAL OF COUPLED SYSTEMS AND MULTISCALE DYNAMICS, 2014, 2 (03) : 164 - 168
  • [50] Sensitive voltammetric detection of DNA damage at carbon electrodes using DNA repair enzymes and an electroactive osmium marker
    Havran, Ludek
    Vacek, Jan
    Cahova, Katerina
    Fojta, Miroslav
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) : 1751 - 1758