Voltammetric detection of damage to DNA caused by nitro derivatives of fluorene using an electrochemical DNA biosensor

被引:53
|
作者
Vyskocil, Vlastimil [1 ]
Labuda, Jan [2 ]
Barek, Jiri [1 ]
机构
[1] Charles Univ Prague, Fac Sci, Dept Analyt Chem, UNESCO Lab Environm Electrochem, Prague 12843 2, Czech Republic
[2] Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, Slovakia
关键词
2-Nitrofluorene; 2,7-Dinitrofluorene; DNA biosensor; Screen printed carbon paste electrode; Electrochemical detection; DNA damage; POLYCYCLIC AROMATIC-HYDROCARBONS; COMPOSITE ELECTRODE; SILVER; 2-NITROFLUORENE; METABOLISM; 1,10-PHENANTHROLINE; POLAROGRAPHY; FLAVONOIDS; COMPLEXES; CARBON;
D O I
10.1007/s00216-010-3517-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An electrochemical DNA biosensor based on the screen printed carbon paste electrode (SPCPE) with an immobilized layer of calf thymus double-stranded DNA has been used for in vitro investigation of the interaction between genotoxic nitro derivatives of fluorene (namely 2-nitrofluorene and 2,7-dinitrofluorene) and DNA. Two types of DNA damage have been detected at the DNA/SPCPE biosensor: first, that caused by direct association of the nitrofluorenes, for which an intercalation association has been found using the known DNA intercalators [Cu(phen)(2)](2+) and [Co(phen)(3)](3+) as competing agents, and, second, that caused by short-lived radicals generated by electrochemical reduction of the nitro group (observable under specific conditions only).
引用
收藏
页码:233 / 241
页数:9
相关论文
共 50 条
  • [21] Levan modified DNA biosensor for voltammetric detection of daunorubicin-DNA interaction
    Congur, Gulsah
    Eksin, Ece
    Erdem, Arzum
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 326
  • [22] Levan modified DNA biosensor for voltammetric detection of daunorubicin-DNA interaction
    Congur, Gulsah
    Eksin, Ece
    Erdem, Arzum
    Sensors and Actuators, B: Chemical, 2021, 326
  • [23] Detection of the effective DNA protection by quinazolines using a DNA-Based electrochemical biosensor
    Ovádeková, R
    Jantová, S
    Labuda, J
    ANALYTICAL LETTERS, 2005, 38 (15) : 2625 - 2638
  • [24] Mechanism of interaction of in situ produced nitroimidazole reduction derivatives with DNA using electrochemical DNA biosensor
    Brett, AMO
    Serrano, SHP
    La-Scalea, MA
    Gutz, IGR
    Cruz, ML
    OXIDANTS AND ANTIOXIDANTS, PT B, 1999, 300 : 314 - 321
  • [25] Voltammetric detection of the DNA interaction with copper complex compounds and damage to DNA
    Labuda, J
    Bucková, M
    Vanícková, M
    Mattusch, J
    Wennrich, R
    ELECTROANALYSIS, 1999, 11 (02) : 101 - 107
  • [26] Fiber optic biosensor for detection of DNA damage
    Rogers, KR
    Apostol, A
    Madsen, SJ
    Spencer, CW
    ANALYTICA CHIMICA ACTA, 2001, 444 (01) : 51 - 60
  • [27] Electrochemical Biosensor for theDetection of DNA Damage by Ionizing Radiation
    Dagdeviren, K.
    Kara, P.
    Bekis, R.
    Ozsoz, S.
    Ulker, O.
    Durak, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S279 - S279
  • [28] Detection of short oligonucleotide sequences using an electrochemical DNA hybridization biosensor
    Girousi, S.
    Kinigopoulou, V.
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2010, 8 (04): : 732 - 736
  • [29] Detection of Short Oligonucleotide Sequences Using an Electrochemical DNA Hybridization Biosensor
    Girousi, Stella
    Kinigopoulou, Vasiliki
    2009 2ND INTERNATIONAL SYMPOSIUM ON APPLIED SCIENCES IN BIOMEDICAL AND COMMUNICATION TECHNOLOGIES (ISABEL 2009), 2009, : 167 - 170
  • [30] Developing a sensitive DNA biosensor for the detection of flutamide using electrochemical method
    Ali A. Ensafi
    Nahid Khademi Farfani
    Maryam Amini
    B. Rezaei
    Journal of the Iranian Chemical Society, 2017, 14 : 1325 - 1334