Sensor/actuator optimal design for active vibration control of shell structure

被引:1
|
作者
Kim, SJ [1 ]
Hwang, JS [1 ]
Mok, J [1 ]
机构
[1] Seoul Natl Univ, Dept Aerosp Engn, Seoul 151742, South Korea
关键词
active vibration control; shell structure; sensor/actuator system; finite element method; genetic algorithm;
D O I
10.1117/12.388874
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, a method based on finite element technique is developed for the design of sensor/actuator system of the active vibration control of shell structure. To prevent the adverse effect of spillover, distributed modal sensor/actuator system is established using PVDF film. Although shell structure is three-dimensional structure, the PVDF sensor/actuator system can be treated as two-dimensional. The electrode patterns and lamination angle of PVDF sensor/actuator are optimized to design the modal sensor/actuator system. Finite element programs are developed to consider curved structures having PVDF modal sensor/actuator. The nice-node shell element with five nodal degree of freedoms is used for finite element discretization. Electrode patterns and lamination angles of PVDF sensor/actuator are optimized using genetic algorithm. Sensor is designed to minimize the observation spillover, and actuator is designed to minimize the system energy of the control modes under a given initial condition. Modal sensor/actuator for the first and second modes of singly curved cantilevered shell structure are designed using above mentioned methods. For the demonstration, numerical simulation of the closed loop system is performed. Discrete LQG method is used as a control law.
引用
收藏
页码:594 / 602
页数:9
相关论文
共 50 条
  • [21] Conical shell vibration control with distributed piezoelectric sensor and actuator layer
    Jamshidi, Rasa
    Jafari, A. A.
    COMPOSITE STRUCTURES, 2021, 256
  • [22] Active vibration control of open spherical shell using photostrictive actuator
    Wang X.-J.
    Yue H.-H.
    Deng Z.-Q.
    Yuhang Xuebao/Journal of Astronautics, 2010, 31 (11): : 2483 - 2490
  • [23] Optimal placement of piezoelectric actuator/sensor pairs for active vibration control of beams with different boundary conditions
    Zhang, Xin Yue
    Chen, Jie
    Zhang, Wei
    MECHANICS BASED DESIGN OF STRUCTURES AND MACHINES, 2025, 53 (03) : 2262 - 2279
  • [24] New Methodology for Optimal Placement of Piezoelectric Sensor/Actuator Pairs for Active Vibration Control of Flexible Structures
    Daraji, Ali H.
    Hale, Jack M.
    Ye, Jianqiao
    JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2018, 140 (01):
  • [25] Optimal sensor/actuator placement for active vibration control using explicit solution of algebraic Riccati equation
    Hiramoto, K
    Doki, H
    Obinata, G
    JOURNAL OF SOUND AND VIBRATION, 2000, 229 (05) : 1057 - 1075
  • [26] Active control of smart structures with optimal actuator and sensor locations
    Liu, PX
    Rao, CS
    Derriso, M
    SMART STRUCTURES AND MATERIALS 2002: MODELING, SIGNAL PROCESSING, AND CONTROL, 2002, 4693 : 1 - 12
  • [27] Actuator design and experimental validation for active gearbox vibration control
    Li, MF
    Lim, TC
    Guan, YH
    Shepard, WS
    SMART MATERIALS AND STRUCTURES, 2006, 15 (01) : N1 - N6
  • [28] Topology optimization of piezoelectric sensor and actuator layers for active vibration control
    Giraldo Guzman, Daniel
    Silva, Emilio C. N.
    Montealegre Rubio, Wilfredo
    SMART MATERIALS AND STRUCTURES, 2020, 29 (08)
  • [29] The optimal placement of actuator and sensor for active noise control of sound-structure interaction systems
    Pulthasthan, Suwit
    Pota, Hemanshu R.
    SMART MATERIALS AND STRUCTURES, 2008, 17 (03)
  • [30] Active vibration control using noncollocated piezoelectric film sensor/actuator
    Nishigaki, Tsutomu
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2011, 2011, 7977