Optimal sensor/actuator placement for active vibration control using explicit solution of algebraic Riccati equation

被引:90
|
作者
Hiramoto, K [1 ]
Doki, H [1 ]
Obinata, G [1 ]
机构
[1] Akita Univ, Dept Mech Engn, Fac Engn & Resource Sci, Akita 0108502, Japan
关键词
D O I
10.1006/jsvi.1999.2530
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper deals with an optimal placement problem of sensors and actuators for active vibration control of flexible structures. For undamped structures with collocated rate sensors and actuators, two solutions of generalized algebraic Riccati equations (generalized control algebraic Riccati equation, GCARE; generalized filtering algebraic Riccati equation, GFARE) are obtained explicitly. Employing these explicit solutions, we can obtain a stabilizing H-infinity controller based on the normalized coprime factorization approach without solving any algebraic Riccati equations numerically. Generally, in a optimal sensor/actuator placement problem with a model-based control law (LQG or H-infinity), the feedback controller needs to be obtained for all candidates of the optimal placement (which may be derived with some numerical optimization techniques) by solving algebraic Riccati equations numerically. Therefore, the amount of computation required to determine the optimal sensor/actuator placement and the controller increases rapidly for large-scale structures which have many pairs of sensor/actuators. The H-infinity controller in this paper can be obtained just by addition and multiplication of several matrices. Furthermore, a closed-loop property on H-infinity norm is automatically bounded for all candidates of the optimal placement. Hence, we can formulate the optimal sensor/actuator placement problem to optimize other closed-loop properties (norm of the closed-loop system) with less computational requirement than the model-based method mentioned above. The gradient of the H-2 norm of the closed-loop system, which is necessary for a descent-based optimization technique, is derived. Using this sensitivity formula, we obtain the optimal placements of two pairs of sensors and actuators which minimize the H-2 norm of the closed-loop system for a simply supported beam by the quasi-Newton method. The simulation results show the effectiveness of the proposed design method.
引用
收藏
页码:1057 / 1075
页数:19
相关论文
共 50 条
  • [1] OPTIMAL SENSOR AND ACTUATOR PLACEMENT FOR ACTIVE VIBRATION CONTROL SYSTEMS
    Spaeh, Britta
    Schittenhelm, Rudolf Sebastian
    Rinderknecht, Stephan
    PROCEEDINGS OF THE ASME NOISE CONTROL AND ACOUSTICS DIVISION CONFERENCE (NCAD 2012), 2013, : 343 - 350
  • [2] Active vibration control of beams with optimal placement of piezoelectric sensor/actuator pairs
    Kumar, K. Ramesh
    Narayanan, S.
    SMART MATERIALS AND STRUCTURES, 2008, 17 (05)
  • [3] Solution of Algebraic Riccati Equation for Optimal Control Using Non-Square Estimator
    Queiroz, Jonathan Araujo
    Neto, Joao Viana da F.
    Barros, Allan Kardec
    2015 IEEE 24TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2015, : 125 - 130
  • [4] Optimal actuator placement for active vibration control of intelligent structure
    Zheng, B
    Yang, JF
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 2552 - 2555
  • [5] Optimal actuator placement for active vibration control with known disturbances
    Mirza, MA
    Van Niekerk, JL
    JOURNAL OF VIBRATION AND CONTROL, 1999, 5 (05) : 709 - 724
  • [6] Co-design of active vibration control and optimal sensor and actuator placement for a flexible wing using reinforcement learning
    He, Tianyi
    Su, Weihua
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2023, 237 (10) : 2240 - 2251
  • [7] New Methodology for Optimal Placement of Piezoelectric Sensor/Actuator Pairs for Active Vibration Control of Flexible Structures
    Daraji, Ali H.
    Hale, Jack M.
    Ye, Jianqiao
    JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2018, 140 (01):
  • [8] Optimal placement of piezoelectric actuator/sensor pairs for active vibration control of beams with different boundary conditions
    Zhang, Xin Yue
    Chen, Jie
    Zhang, Wei
    MECHANICS BASED DESIGN OF STRUCTURES AND MACHINES, 2024,
  • [9] Optimal piezoelectric actuator and sensor location for active vibration control, using genetic algorithm
    Bruant, Isabelle
    Gallimard, Laurent
    Nikoukar, Shahrarn
    JOURNAL OF SOUND AND VIBRATION, 2010, 329 (10) : 1615 - 1635
  • [10] A sensor and actuator placement technique for active vibration control using H2 norm
    Ambrosio, Pasquale
    Ripamonti, Francesco
    Resta, Ferruccio
    Braghin, Francesco
    2013 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS (ICM), 2013,