A model of respiratory airway motion for real-time tracking of an ultrathin bronchoscope

被引:6
|
作者
Soper, Timothy D. [1 ]
Haynor, David R. [1 ,2 ]
Glenny, Robb W. [1 ,3 ]
Seibel, Eric J. [1 ,4 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[3] Univ Washington, Pulmonary & Critical Care Med, Seattle, WA 98195 USA
[4] Univ Washington, Mech Engn, Seattle, WA 98195 USA
关键词
registration; lung; airways; bronchoscopy; respiration; breathing; CT;
D O I
10.1117/12.710150
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Deformable registration of chest CT scans taken of a subject at various phases of respiration provide a direct measure of the spatially varying displacements that occur in the lung due to breathing. This respiratory motion was studied as part of the development of a CT-based guidance system for a new electromagnetically tracked ultrathin bronchoscope. Fifteen scans of an anesthesized pig were acquired at five distinct lung pressures between full expiration to full inspiration. Deformation fields were computed by non-rigid registration using symmetric "demons" forces followed by Gaussian regularization in a multi-resolution framework. Variants of the registration scheme were tested including: initial histogram matching of input images, degree of field smoothing during regularization, and applying an adaptive smoothing method that weights elements of the smoothing kernel by the magnitude of the image gradient. Registration quality was quantified and compared using inverse and transitive consistency metrics. After optimizing the algorithm parameters, deformation fields were computed by registering each image in the set to a baseline image. Registration of the baseline image at full inspiration to an image at full expiration produced the maximum deformation. Two hypotheses were made: first, that each deformation could be modeled as a mathematical sub-multiple of the maximum deformation, and second, that the deformation scales linearly with respiratory pressure. The discrepancy between the deformation measured by image registration and that predicted by the linear model was 1.25 mm. on average. At maximum deformation, this motion compensation constitutes an 87% reduction in respiration-induced localization error.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Model-Based Real-Time Motion Tracking Using Dynamical Inverse Kinematics
    Rapetti, Lorenzo
    Tirupachuri, Yeshasvi
    Darvish, Kourosh
    Dafarra, Stefano
    Nava, Gabriele
    Latella, Claudia
    Pucci, Daniele
    ALGORITHMS, 2020, 13 (10)
  • [32] Predictive Tracking for Real-Time Deformable Motion Using a Dynamic Virtual Patient Model
    Guo, B.
    Xu, X.
    Shi, C.
    MEDICAL PHYSICS, 2011, 38 (06) : 3781 - +
  • [33] Real-time prediction of respiratory motion based on a local dynamic model in an augmented space
    Hong, S-M
    Jung, B-H
    Ruan, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06): : 1775 - 1789
  • [34] respiTrack: Patient-specific real-time respiratory tumor motion prediction using magnetic tracking
    Ozbek, Yusuf
    Bardosi, Zoltan
    Freysinger, Wolfgang
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2020, 15 (06) : 953 - 962
  • [35] respiTrack: Patient-specific real-time respiratory tumor motion prediction using magnetic tracking
    Yusuf Özbek
    Zoltán Bárdosi
    Wolfgang Freysinger
    International Journal of Computer Assisted Radiology and Surgery, 2020, 15 : 953 - 962
  • [36] Comparison of real-time tracking & 4D inverse planning for managing patient respiratory motion
    Zhang, P.
    Yan, D.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S29 - S30
  • [37] Respiratory-Induced Prostate Motion Using Wavelet Decomposition of the Real-Time Electromagnetic Tracking Signal
    Lin, Yuting
    Liu, Tian
    Yang, Xiaofeng
    Wang, Yuenan
    Khan, Mohammad K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : 370 - 374
  • [38] Comparison of real-time tracking & 4D inverse planning for managing patient respiratory motion
    Zhang, P.
    Yan, D.
    Hugo, G.
    MEDICAL PHYSICS, 2007, 34 (06) : 2335 - 2336
  • [39] A new approach for tracking respiratory mechanical parameters in real-time
    Avanzolini, G
    Barbini, P
    Cappello, A
    Cevenini, G
    Chiari, L
    ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (01) : 154 - 163
  • [40] A new approach for tracking respiratory mechanical parameters in real-time
    Guido Avanzolini
    Paolo Barbini
    Angelo Cappello
    Gabriele Cevenini
    Lorenzo Chiari
    Annals of Biomedical Engineering, 1997, 25 : 154 - 163