Comparison of real-time tracking & 4D inverse planning for managing patient respiratory motion

被引:0
|
作者
Zhang, P. [1 ]
Yan, D. [1 ]
Hugo, G. [1 ]
机构
[1] William Beaumont Hosp, Royal Oak, MI 48072 USA
关键词
D O I
10.1118/1.2760367
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Real‐time tracking and 4D‐planning at the mean target position have been two potential methodologies to manage respiratory target motion. In this study, we evaluated each method based on dose‐volume criteria of organs in lung cancer radiotherapy. Method and Materials: Four patients with respiratory target excursions 1.5cm to 3.0cm were included. Each patient had 4D‐CT scans at 10 breathing phases. Deformable organ registration was applied to obtain subvolume displacement mapping for each phase of CT image. First, an idealized real‐time tracking technique was evaluated assuming perfect estimation of target motion and beam tracking. Inverse planning was performed on each breathing phase CT image without using margins for target and normal structures. Treatment dose was accumulated from does of each breathing phase. Secondly, a 4D‐inverse planning was performed on the mean 4D‐CT image using the corresponding pdf of respiratory motion created from the 4D‐CTs. Same beams and prescription dose (70Gy), as well as same objective and constraints, were applied in the planning optimization, and the cumulative dose was constructed accordingly. DVH and EUD in the GTV, lung, heart and cord were used for the evaluation. Results: Cumulative doses in target are similar for both techniques. The beam intensity modulation in the 4D inverse planning is much higher than the one in the real‐time tracking, but it can be delivered using beam compensator. Lung, heart and cord DVHs are similar with the corresponding EUDs, 4.6±2.2Gy, 8.3±4.6Gy and 11±4.35Gy for the tracking technique, and 5.3±2.3Gy, 8.8±5.1Gy and 11.9±5.0Gy for the 4D inverse planning. Conclusion: Treatment technique with the 4D‐inverse planning and online mean target position control is clinically practical. Compared to the idealized real‐time tracking, 4D‐inverse planning achieves slightly degraded, but similar. However, this degradation could be vanished when practical tracking error was considered. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2335 / 2336
页数:2
相关论文
共 50 条
  • [1] Comparison of real-time tracking & 4D inverse planning for managing patient respiratory motion
    Zhang, P.
    Yan, D.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S29 - S30
  • [2] PLANNING STUDY COMPARISON OF REAL-TIME TARGET TRACKING AND FOUR-DIMENSIONAL INVERSE PLANNING FOR MANAGING PATIENT RESPIRATORY MOTION
    Zhang, Peng
    Hugo, Geoffrey D.
    Yan, Di
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 1221 - 1227
  • [3] Patient Motion & 4D Inverse Planning
    Bortfeld, T.
    Trofimov, A.
    Unkelbach, J.
    Martin, B.
    Nohadani, O.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [4] Sensitivity of Respiratory Motion Pattern On 4D Inverse Planning Dose
    Zhang, P.
    Zhang, T.
    Yan, D.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [5] Real-Time 4D Reconstruction of Human Motion
    Hapak, Jozsef
    Janko, Zsolt
    Chetverikov, Dmitry
    ARTICULATED MOTION AND DEFORMABLE OBJECTS, 2012, 7378 : 250 - 259
  • [6] Online 4D ultrasound guidance for real-time motion compensation by MLC tracking
    Ipsen, Svenja
    Bruder, Ralf
    O'Brien, Rick
    Keall, Paul J.
    Schweikard, Achim
    Poulsen, Per R.
    MEDICAL PHYSICS, 2016, 43 (10) : 5695 - 5704
  • [7] SENSITIVITY STUDY OF PATIENT RESPIRATORY MOTION UNCERTAINTY ON 4D IMRT PLANNING
    Yan, D.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S23 - S23
  • [8] Determination and validation of a 4D trajectory for respiration-induced real-time tumor motion tracking
    Van Liew, S.
    Nazareth, D.
    D'Souza, W.
    MEDICAL PHYSICS, 2006, 33 (06) : 2030 - 2030
  • [9] Real-Time 4D Ultrasound Prostate Gland Motion Tracking During Radiotherapy Fraction Delivery
    Sandhu, R.
    Marina, O.
    Wloch, J.
    Martin, S.
    Krauss, D.
    Yan, D.
    Ionascu, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Real-time block flow tracking of atrial septal defect motion in 4D cardiac ultrasound
    Linguraru, Marius George
    Kabla, Alexandre
    Vasilyev, Nikolay V.
    del Nido, Pedro J.
    Howe, Robert D.
    2007 4TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING : MACRO TO NANO, VOLS 1-3, 2007, : 356 - +