An innovative tool for groundwater velocity measurement compared with other tools in laboratory and field tests

被引:8
|
作者
Essouayed, E. [1 ]
Annable, M. D. [2 ]
Momtbrun, M. [1 ]
Atteia, O. [3 ]
机构
[1] Univ Bordeaux Montaigne, EA Georessources & Environm 4592, Bordeaux INP ENSEGID, INNOVASOL, 1 Allee Daguin, F-33600 Pessac, France
[2] Univ Florida, Dept Environm Engn Sci, Gainesville, FL 32611 USA
[3] Univ Bordeaux Montaigne, Carnot ISIFoR, EA Georessources & Environm 4592, Bordeaux INP ENSEGID, 1 Allee Daguin, F-33600 Pessac, France
来源
JOURNAL OF HYDROLOGY X | 2019年 / 2卷
关键词
Direct velocity tool; Darcy flux measurement; Laboratory and field comparison; Innovative;
D O I
10.1016/j.hydroa.2018.100008
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
An innovative solution for groundwater velocity measurement in wells, the Direct Velocity Tool (DVT), is developed and tested. The DVT allows measurement of Darcy flux at centimeter scale vertical resolution requiring only a few minutes for each measurement (typically 5-10 min). Results are generated in real time through the use of an equation. The theoretical functional Darcy flux range is between 1 and 40 cm.day (1) for an aquifer with a hydraulic conductivity, K, less than 10 (3) m.s (1). Laboratory tests showed a linear response between Darcy flux imposed and Darcy flux measured with the DVT, with a high correlation coefficient (R-2 = 0.99). The DVT was tested for velocities ranging from 5 to 30 cm.day (1) where a higher standard deviation was observed for higher velocity (+/- 6.46 cm.day 1 for 30 cm.day (1)). At a hydraulically controlled field site, tracer tests, borehole dilutions, Passive Flux Meter (PFM) and DVT were tested under constant flow conditions. The PFM, tracer test and DVT technologies measured similar Darcy flux ranging from 10 to 17 cm.day (1). The DVT and PFM had uncertainties of 2.70 cm.day (1) and 2.50 cm.day (1), respectively. At a contaminated field site, velocities measured with the PFM range between 5 and 9 cm.day (1), while the DVT provided velocities of 4 to 8 cm.day (1). Velocity measurement showed similar results at the contaminated field site between PFM and DVT. The DVT offers an innovative solution for Darcy flux measurement and can be deployed easily. It provides the capability to characterize the vertical distribution of the horizontal velocity for a well in a period of 1-2 h. (C) 2018 The Author(s). Published by Elsevier B.V.
引用
收藏
页数:9
相关论文
共 44 条
  • [31] Nonlinear Guided Waves for Neutral Temperature Measurement in Continuous Welded Rails: Results from Laboratory and Field Tests
    Nucera, Claudio
    Phillips, Robert
    Zhu, Peter
    Mariani, Stefano
    di Scalea, Francesco Lanza
    Fateh, Mahmood
    Carr, Gary
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2013, 2013, 8695
  • [32] Potential Impacts of CO2 Leakage on Groundwater Chemistry from Laboratory Batch Experiments and Field Push-pull Tests
    Mickler, Patrick J.
    Yang, Changbing
    Scanlon, Bridget R.
    Reedy, Robert
    Lu, Jiemin
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (18) : 10694 - 10702
  • [33] The effectiveness of the clinical self-assessment (MHAQ) compared with other clinical and laboratory tests used to monitor the activity of rheumatoid arthritis by consensus analysis
    Finley, JM
    Colburn, KK
    Putnoky, GJ
    Westengard, JC
    Bull, BS
    JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 1999, 5 (04) : 201 - 205
  • [34] Reproducibility estimates from single-laboratory ruggedness tests compared with those derived from collaborative trials of six microbiological measurement methods
    Keith Jewell
    Heather Leach
    Christopher Baylis
    Accreditation and Quality Assurance, 2009, 14 : 123 - 137
  • [35] Reproducibility estimates from single-laboratory ruggedness tests compared with those derived from collaborative trials of six microbiological measurement methods
    Jewell, Keith
    Leach, Heather
    Baylis, Christopher
    ACCREDITATION AND QUALITY ASSURANCE, 2009, 14 (03) : 123 - 137
  • [36] Field-portable X-ray fluorescence spectrometry as rapid measurement tool for landfill mining operations: comparison of field data vs. laboratory analysis
    Burlakovs, Juris
    Kaczala, Fabio
    Orupold, Kaja
    Bhatnagar, Amit
    Vincevica-Gaile, Zane
    Rudovica, Vita
    Kriipsalu, Mait
    Hogland, Marika
    Stapkevica, Mara
    Hogland, William
    Klavins, Maris
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2015, 95 (07) : 609 - 617
  • [37] Field-portable X-ray fluorescence spectrometry as rapid measurement tool for landfill mining operations: comparison of field data vs. laboratory analysis
    Department of Environmental Science, University of Latvia, Riga
    LV-1586, Latvia
    不详
    391 82, Sweden
    不详
    51014, Estonia
    不详
    FI-70211, Finland
    不详
    LV-1586, Latvia
    Int. J. Environ. Anal. Chem., 7 (609-617):
  • [38] Groundwater transport of colloids and heavy metals at a former lignite mining site - Field studies and laboratory tests [Sickerwassertransport von Kolloiden und Schwermetallen in Bergbaufolgelandschaften - Felduntersuchungen und Laborversuche]
    Baumann T.
    Fruhstorfer P.
    Niessner R.
    Grundwasser, 1998, 3 (1) : 3 - 13
  • [39] ISOLATION OF TRIC AGENT (CHLAMYDIA) IN IRRADIATED MCCOY CELL CULTURE FROM ENDEMIC TRACHOMA IN FIELD STUDIES IN IRAN - COMPARISON WITH OTHER LABORATORY TESTS FOR DETECTION OF CHLAMYDIA
    DAROUGAR, S
    TREHARNE, JD
    DWYER, RSC
    KINNISON, JR
    JONES, BR
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1971, 55 (09) : 591 - &
  • [40] Host specificity of the rubber vine moth, Euclasta whalleyi Popescu-Gorj and Constantinescu (Lepidoptera: Crambidae: Pyraustinae):: field host-range compared to that predicted by laboratory tests
    McFadyen, REC
    Vitelli, M
    Setter, C
    AUSTRALIAN JOURNAL OF ENTOMOLOGY, 2002, 41 : 321 - 323