Determination of iron in blood serum using flow injection with luminol chemiluminescence detection

被引:12
|
作者
Waseem, A [1 ]
Yaqoob, M [1 ]
Nabi, A [1 ]
机构
[1] Univ Baluchistan, Dept Chem, Quetta, Pakistan
关键词
flow injection analysis; chemiluminescence; iron; blood serum;
D O I
10.1002/bio.787
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid flow injection method is reported for the determination of iron in blood serum after acid digestion with HNO3 and HClO4, based on luminol CL detection in the absence of added oxidant. The detection limit (3 s) was 1.0 nmol/L with a sample throughput of 120/h. The calibration graph was linear over the range 0.001-1.0 mumol/L (r(2) = 0.9974), with relative standard deviations (RSD) (n = 4) in the range 3.2-5%. The effect of interfering cations (Ca(II), Mg(II), Cu(II), Cd(II), Pb(II), Mn(II), Zn(II), Ni(II), Co(II) and Fe(III)) and anions (Cl-, SO42-, HCO3-, NO3-, NO2-) were studied using a luminol CL system for Fe(II) determination. The method was applied to normal blood serum and the results (1.32 +/- 0.08-1.74 +/- 0.05 mg/L) were compared with those from a spectrophotometric reference method (1.34 +/- 0.06-1.80 +/- 0.10 mg/L), which agree fairly well with the overall reference range in blood. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 50 条
  • [41] Sensitive determination of ketoprofen using flow injection with chemiluminescence detection
    Zhuang, Yafeng
    Song, Hengli
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (03) : 824 - 828
  • [42] Determination of Mancozeb and Maneb using flow injection chemiluminescence detection
    Asghar, Muhammad
    Yaqoob, Mohammad
    Munawar, Nusrat
    Nabi, Abdul
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (11) : 2586 - 2606
  • [43] FLOW-INJECTION DETERMINATION OF IRON(II),IRON(III) AND TOTAL IRON WITH CHEMILUMINESCENCE DETECTION
    SARANTONIS, EG
    TOWNSHEND, A
    ANALYTICA CHIMICA ACTA, 1986, 184 : 311 - 315
  • [44] Ultrasensitive determination for picomolar-level midecamycin in human serum by flow injection chemiluminescence using luminol-BSA system
    Lv, Hairu
    Tan, Xijuan
    Zhang, Yun
    Song, Zhenghua
    SPECTROSCOPY-BIOMEDICAL APPLICATIONS, 2011, 26 (06): : 349 - 355
  • [45] Flow injection determination of hydrogen peroxide using diperiodatoargentate- and diperiodatonickelate-luminol chemiluminescence
    Yang, Chunyan
    Zhang, Zhujun
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (05) : 523 - 533
  • [46] Flow injection chemiluminescence determination of polyhydroxy phenols using luminol-ferricyanide/ferrocyanide system
    Du, JX
    Li, YH
    Lu, JR
    TALANTA, 2001, 55 (06) : 1055 - 1058
  • [47] Flow injection chemiluminescence determination of fenitrothion pesticide using luminol-hydrogen peroxide system
    Liu, Xiaoyu
    Li, Aifang
    Wu, Chengmou
    Lu, Jiuru
    ANALYTICAL LETTERS, 2007, 40 (14) : 2737 - 2746
  • [48] Determination of metlhyl-parathion using luminol-based chemiluminescence flow injection method
    Rao, ZM
    Wang, JN
    Li, LD
    Zhang, XR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (04) : 373 - 377
  • [49] Determination of dopamine by flow-injection analysis coupled with luminol-hexacyanoferrate(III) chemiluminescence detection
    Nalewajko, E
    Ramírez, RB
    Kojlo, A
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (01) : 219 - 223
  • [50] Determination of Epinephrine by Flow Injection Analysis Coupled Ag(III) Complex-Luminol Chemiluminescence Detection
    Bai Jiangbo
    Shi Hongmei
    Zhang Yingze
    Tian Dehu
    Xu Xiangdong
    Kang Weijun
    CHINESE JOURNAL OF CHEMISTRY, 2009, 27 (04) : 745 - 750