Determination of iron in blood serum using flow injection with luminol chemiluminescence detection

被引:12
|
作者
Waseem, A [1 ]
Yaqoob, M [1 ]
Nabi, A [1 ]
机构
[1] Univ Baluchistan, Dept Chem, Quetta, Pakistan
关键词
flow injection analysis; chemiluminescence; iron; blood serum;
D O I
10.1002/bio.787
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid flow injection method is reported for the determination of iron in blood serum after acid digestion with HNO3 and HClO4, based on luminol CL detection in the absence of added oxidant. The detection limit (3 s) was 1.0 nmol/L with a sample throughput of 120/h. The calibration graph was linear over the range 0.001-1.0 mumol/L (r(2) = 0.9974), with relative standard deviations (RSD) (n = 4) in the range 3.2-5%. The effect of interfering cations (Ca(II), Mg(II), Cu(II), Cd(II), Pb(II), Mn(II), Zn(II), Ni(II), Co(II) and Fe(III)) and anions (Cl-, SO42-, HCO3-, NO3-, NO2-) were studied using a luminol CL system for Fe(II) determination. The method was applied to normal blood serum and the results (1.32 +/- 0.08-1.74 +/- 0.05 mg/L) were compared with those from a spectrophotometric reference method (1.34 +/- 0.06-1.80 +/- 0.10 mg/L), which agree fairly well with the overall reference range in blood. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 50 条
  • [31] Flow-injection determination of cysteine in pharmaceuticals based on luminol-persulphate chemiluminescence detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    LUMINESCENCE, 2008, 23 (03) : 144 - 149
  • [32] Flow-injection determination of ornidazole by chemiluminescence detection based on a luminol-ferricyanide reaction
    Lv, Y
    Zhang, ZJ
    He, DY
    Hu, YF
    ANALYTICAL SCIENCES, 2003, 19 (04) : 625 - 627
  • [33] Sensitive determination of captopril by flow injection analysis with chemiluminescence detection based on the enhancement of the luminol reaction
    Economou, A
    Themelis, DG
    Theodoridis, G
    Tzanavaras, PD
    ANALYTICA CHIMICA ACTA, 2002, 463 (02) : 249 - 255
  • [34] Flow injection chemiluminescence determination of dobutamine hydrochloride injection using luminol-ferricyanide/ferrocyanide system
    Liu, HY
    Zhang, L
    Zhou, JM
    Hao, YH
    He, PG
    Fang, YZ
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 125 - 129
  • [35] Determination of Cr(III) in urine, blood serum and hair using flow injection chemiluminescence analysis
    Escobar, R
    Garcia-Dominguez, MS
    Guiraum, A
    de la Rosa, FF
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (05): : 509 - 511
  • [36] Determination of Cr(III) in urine, blood serum and hair using flow injection chemiluminescence analysis
    R. Escobar
    M. S. García-Domínguez
    A. Guiraúm
    F. F. de la Rosa
    Fresenius' Journal of Analytical Chemistry, 1998, 361 : 509 - 511
  • [37] Determination of adenosine 5′-triphosphate by flow injection with luminol chemiluminescence detection using immobilized alkaline phosphatase enzyme reactor
    Anwar, M
    Yaqoob, M
    Nabi, A
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2005, 27 (06): : 615 - 620
  • [38] Determination of total iron in fresh waters using flow injection with potassium permanganate chemiluminescence detection
    Yaqoob, M.
    Waseem, A.
    Nabi, A.
    Journal of Analytical Chemistry, 2006, 61 (09): : 917 - 921
  • [39] Determination of sub-nanomolar levels of iron in seawater using flow injection with chemiluminescence detection
    Bowie, AR
    Achterberg, EP
    Mantoura, RFC
    Worsfold, PJ
    ANALYTICA CHIMICA ACTA, 1998, 361 (03) : 189 - 200
  • [40] Determination of total iron in fresh waters using flow injection with potassium permanganate chemiluminescence detection
    M. Yaqoob
    A. Waseem
    A. Nabi
    Journal of Analytical Chemistry, 2006, 61 : 917 - 921